Brand: Hanna Instruments
Hanna HI8734 Three-Range Portable TDS Meter 0-19.99 g/L
Description
Hanna HI8734 three-range portable TDS meter
The Hanna HI8734 is a portable total dissolved solids meter with three ranges from 0.0 mg/L to 19.99 g/L, supplied with the HI76301D four-ring conductivity probe. It converts conductivity to TDS using a 0.5 factor and suits water-quality checks where the limit is written as mg/L. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
It uses the same manual as the HI8733 EC meter, but the model number selects TDS units, a three-position range switch and a calibration sachet of 1382 mg/L (HI70032).
HI8734 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Hanna Instruments HI8734 |
| TDS ranges | 0.0 to 199.9 mg/L (ppm); 0 to 1999 mg/L (ppm); 0.00 to 19.99 g/L (ppt) |
| Resolution | 0.1 mg/L; 1 mg/L; 0.01 g/L |
| Accuracy at 25 °C | ±1 % of full scale, excluding probe error |
| Conversion factor | 0.5 |
| Calibration | Manual, one point with the TDS knob |
| Temperature compensation | Manual, 0 to 50 °C with beta = 2 %/°C |
| Probe | HI76301D four-ring conductivity probe with DIN connector and 1 m cable |
| Power | One 9 V alkaline battery; about 100 hours of continuous use |
| Environment | 0 to 50 °C; RH up to 95 % |
| Size / weight | 145 × 80 × 36 mm; 230 g |
| Supplied with | HI76301D probe, HI70032 1382 mg/L calibration sachet, battery, instructions |
| Warranty | Two years |
How the HI8734 works
The meter measures the conductivity of the sample through a four-ring probe and multiplies it by a conversion factor of 0.5 to display TDS. The factor is a convention and real TDS depends on the ion mix, so for non-standard waters a laboratory gravimetric comparison can be used to check suitability.
Temperature correction on this model is fixed to a beta coefficient of 2 % per degree C and applied for samples between 0 and 50 °C, so very precise work should measure close to 25 °C. Calibration is a single manual adjustment of the TDS knob with the probe in the HI70032 1382 mg/L standard.
Where HI8734 fits: sensors, accessories and related models
The HI76301D four-ring probe is supplied with the meter. Four-ring designs are less sensitive to coating and sample volume than two-pole cells, which helps in dirty process waters. Calibration standards beyond the 1382 mg/L sachet are separate consumables.
The table contrasts the HI8734 with the HI8733, since buyers sometimes order the wrong parameter.
HI8734 family comparison
| Model | Reads | Ranges | Temperature compensation |
|---|---|---|---|
| HI8733 | EC | 4 ranges, 0.0 µS/cm to 199.9 mS/cm | Automatic, adjustable beta |
| HI8734 | TDS | 3 ranges, 0.0 mg/L to 19.99 g/L | Manual, beta = 2 %/°C |
If your specification mentions both conductivity and TDS, the HI98195 or HI98194 multiparameter meters give EC, TDS, salinity and resistivity together from a single probe.
Selection and ordering checklist for HI8734
- Confirm TDS in mg/L or g/L is the required unit
- Check that the 0.5 conversion factor suits your water, or plan laboratory cross-checks
- Quote additional calibration standards if needed
- Decide on a spare HI76301D probe
- Plan for a 9 V alkaline battery
Installation, calibration and maintenance of HI8734
Rinse the probe with deionised water and the sample, immerse it fully and tap out bubbles, then calibrate with the TDS knob in the 1382 mg/L standard on the matching range. Recalibrate each shift or after a range change.
Clean the four rings with the manual-recommended method if a film forms, avoid scratching them, and store the probe clean and dry. Because temperature compensation is fixed, let cold or hot samples approach room temperature before the final reading.
In field audits it is useful to note the sample temperature next to the TDS value, because a reading taken at 40 °C with a fixed beta of 2 % per degree carries more uncertainty than one at 25 °C.
Keep a small bottle of calibration standard in the carrying kit and replace it after it has been opened for some weeks, since evaporation and contamination alter its value.
Because TDS values are derived and not measured directly, state the conversion factor used whenever results are reported, so that a reader who prefers a different factor can recompute. When comparing two sites, use the same range, the same temperature and the same calibration standard, and avoid reading in moving water that carries air bubbles past the rings. A short soak in deionised water between samples prevents carry-over between very different TDS levels. If the instrument will be used in the field for several days, carry spare batteries, because a weak 9 V cell causes unstable readings before it fails completely, and check the probe cable for kinks after each trip.
Typical applications of HI8734 in Oman and the GCC
Typical uses in Oman include screening of drinking water and bottled water, reverse-osmosis permeate checks, irrigation and aquaculture water assessment, cooling-water and boiler make-up screening, and quick TDS verification at tanker filling points.
The three-range switch lets one meter handle both low-TDS permeate and higher-TDS brackish sources without changing the probe.
Information to send with an RFQ for HI8734
- Quantity and spare probes
- Calibration standards required
- Expected TDS range and application
- Delivery location and lead time
- Project or tender reference
Storage, handling and spares for the Hanna HI8734
Store the Hanna HI8734 in its case in a clean, dry place. Keep probes, electrodes and reagents as described in the user manual, as many of them need a storage solution or have a limited shelf life. In the GCC climate, keep reagents away from heat and direct sun and check expiry dates before use.
- Calibrate the instrument with fresh standards at the interval your procedure requires.
- Rinse probes and sample cells after each use and inspect them for scratches or deposits.
- Keep spare consumables, such as reagents, standards, cuvettes and electrode solutions, in stock.
- Record calibration results so that drift or probe ageing can be seen early.
When you order the Hanna HI8734, list the consumables and standards you need in the same RFQ, so the instrument can be used from the day it arrives.
Documents and quotation
The instruction manual for the HI8734 is attached on this page for specifications, calibration procedures and maintenance steps. The same document covers the HI8733.
Send the part number HI8734, the quantity and your delivery location and we will reply with availability and a quotation.
Other Models in the Hanna Ec Tds Meter Range
Seven Star LLC supplies models from the Hanna Ec Tds Meter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Hanna HI8733 Multi-Range Portable EC Meter 0-199.9 mS/cm | Liquid Analytical Systems | View details |
| Hanna HI8734 Three-Range Portable TDS Meter 0-19.99 g/L | Liquid Analytical Systems | You are viewing this model |
Datasheets & Documents
- Manual Hanna HI8734 Instruction Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Hanna Instruments is a maker of analytical instruments for water and liquid testing, founded in 1978 in the Padua area of Italy by Oscar and Anna Nardo. Its early breakthrough was the pHep, an affordable pocket-sized pH tester. The company is now led by the founders' children, Martino and Pamela Nardo, with its headquarters in Woonsocket, Rhode Island, and offers more than 3,000 products.
Seven Star LLC is an independent supplier in Muscat. We list Hanna instruments for water, wastewater and laboratory users in Oman and the GCC.
Hanna Instruments company profile
| Founded | 1978, near Padua, Italy, by Oscar and Anna Nardo |
|---|---|
| Headquarters | Woonsocket, Rhode Island, USA |
| Leadership | Martino Nardo and Pamela Nardo |
| Early product | The pHep pocket pH tester |
| Product families | pHep and HI98 waterproof testers, edge benchtop meters, HI83 multiparameter photometers, Checker HC handheld colorimeters, HI931 and HI932 titrators, process controllers, reagents and calibration buffers |
Hanna product series
Portable meters include the HI98190 pH and ORP meter, the HI98192 EC, TDS and salinity meter, the HI98193 dissolved oxygen and BOD meter, the HI98199 pH, EC and DO meter and the HI9829 multiparameter water quality meter.
The HI98703 is an EPA compliant portable turbidity meter, the HI97711 a free and total chlorine photometer and the HI83414 a benchtop turbidity and chlorine meter.
Waterproof portable meters such as the HI98190 and HI98192 suit field use, with automatic temperature compensation and GLP data for audits. Turbidity measurement with the HI98703 follows EPA method 180.1, and the HI97711 photometer measures free and total chlorine for disinfection control.
Where Hanna instruments are used
Drinking water and desalination plants, wastewater treatment, environmental field surveys, aquaculture, cooling water and quality control labs.
Hanna Instruments products we list
Ordering Hanna instruments: what we need
Send the model, the parameters and ranges, the probe and cable length and any reagents or calibration solutions required.
Facts checked against Hanna Instruments' own company story and City of Woonsocket business profile, October 2026.
Browse Hanna Instruments products by category: Portable Test & Measurement.
FAQ
Questions about the Hanna HI8734 Three-Range Portable TDS Meter 0-19.99
Answers from our engineering team on installation, compatibility and integration.
01What ranges does the HI8734 cover?
Three TDS ranges: 0.0 to 199.9 mg/L, 0 to 1999 mg/L and 0.00 to 19.99 g/L, with accuracy of 1 percent of full scale.
02What conversion factor does it use?
A fixed TDS conversion factor of 0.5 applied to the measured conductivity.
03Is temperature compensation automatic?
No. It is manual from 0 to 50 degrees C with a beta coefficient of 2 percent per degree C.
04How is it calibrated?
At one point with the TDS knob, using the supplied HI70032 1382 mg/L calibration sachet.
05What probe is included?
The HI76301D four-ring conductivity probe with DIN connector and 1 m cable.