Honeywell PUL6438S Spyder Lon Unitary Controller 6 UI 4 DI 8 DO
Description
Overview of the Honeywell PUL6438S
The Honeywell PUL6438S is the full-size Spyder Lon unitary controller: six universal inputs, four digital inputs, three analog outputs and eight Triac digital outputs on one LONMARK board. It is the unit chosen when a single air handler, heat-pump bank or multi-stage packaged system needs sensing, status inputs and many stages from one node.
Content here is taken from the Honeywell Spyder Lon product data, form 63-2685. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Inputs and outputs in detail
Universal inputs first. Each UI accepts 20K ohm NTC room, discharge or outdoor sensors, the C7031G (minus 40 to 120 F) and C7041F (minus 40 to 250 F) sensors, PT1000 (IEC751 3850), TR23 setpoint potentiometers of 500 to 10,500 ohm, 0 to 10 Vdc transducers, generic resistive inputs from 100 ohm to 100K ohm and dry contacts. Unlike the smaller unitary models, the datasheet footnote on pulse metering excludes the PUL6438S, so none of its six inputs is a fast pulse meter.
Next, the digital inputs. These detect dry contacts: open above 3000 ohm reads False, closed below 500 ohm reads True, with up to 30 Vdc present on an open circuit. The wiring notes call for contacts suitable for dry switching of 5 V at 10 mA, preferably sealed, gold-flashed or pimpled types. Typical uses are filter differential switches, fan proofs, freeze stats and smoke-damper end switches.
Finally the outputs. Analog outputs can be 4 to 20 mA into no more than 550 ohm or 0 to 10 Vdc at up to 10 mA, and can be re-purposed as digital outputs that give 0 Vdc for false and about 11 Vdc for true. The eight Triacs are rated 20 to 30 Vac at 25 to 500 mA continuous.
PUL6438S data table
| Parameter | Value |
|---|---|
| Model | PUL6438S Spyder Lon unitary |
| UI / DI / AO / DO | 6 / 4 / 3 / 8 |
| Rated supply | 20 to 30 Vac, 50/60 Hz, Class 2 energy-limited source |
| Maximum power draw incl. loads | 100 VA |
| Network | LONWORKS FTT-10A, 78 kbps, LONMARK compliant, communication terminals 7 and 8 |
| Sensor power output | 20 Vdc plus or minus 10 percent at 75 mA maximum |
| Triac digital output rating | 20 to 30 Vac, 25 mA to 500 mA continuous, 800 mA for 60 ms |
| Analog output | Configurable 4 to 20 mA (550 ohm maximum load) or 0 to 10 Vdc (10 mA maximum) |
| Operating and storage temperature | minus 40 to 150 F (minus 40 to 65.5 C) |
| Humidity | 5 to 95 percent, non-condensing |
| Real time clock backup | 24 hours at 32 to 100 F, 22 hours at 100 to 122 F; accuracy plus or minus 1 minute per month at 77 F |
| Controller-only load | 5 VA maximum |
| Enclosure depth | 2-1/4 in (57 mm), wide enclosure per Fig. 7 |
| Mounting | Panel or DIN rail; the cover need not be removed for mounting or wiring |
How PUL6438S differs from other Spyder Lon variants
Relative to PUL4024S the PUL6438S adds two universal inputs, four digital inputs, one analog output and four Triac outputs, and it moves to the larger Fig. 7 footprint. Relative to the VAV pair PVL6436AS and PVL6438NS the point count is the same (6 UI, 4 DI, 3 AO) but those add a velocity pressure sensor, and the PVL6436AS includes a damper actuator; the PUL6438S is the one to pick when air volume is not measured at the controller. Its 8 Triacs match the PVL6438NS.
Application ideas for Gulf projects
A district-cooling energy transfer station with temperature, valve and pump status, a switchgear room HVAC skid with several fans and alarm contacts, or a clean-room air handler where each stage has its own interlock input. In plants with a LONWORKS backbone it removes the need for an extra I/O node.
Because all six UI, four DI and three AO channels are on one board, it also simplifies spares: one stocked PUL6438S can stand in for the smaller unitary models in the family as long as the application only uses the channels the original program needed, since the downloadable program decides how each terminal is used.
Panel builders should note that the Honeywell design guidance allows several controllers to share one transformer provided the same side of the secondary goes to the same power terminal on each, the earth terminal is grounded on every unit, and the total draw including accessories stays at or below 100 VA where Class 2 limits apply.
Commissioning checklist
1. Confirm 24 Vac on terminals 1 and 2 and earth on terminal 3. 2. Check bus continuity on terminals 7 and 8 and the termination module count. 3. Download the application from the WEBpro workbench. 4. Exercise each of the PUL6438S outputs in manual mode. 5. Verify the sensor offsets against a reference thermometer and record the as-found values for the handover file. 6. Release manual mode on every point and watch the LED return to normal operation before leaving the site.
Service life notes
Routine care for PUL6438S is limited to retightening terminals, checking the LED state and keeping the cover vents clear. Controller replacement is done by removing power, pulling the terminal blocks, removing the old unit (push up from the bottom on DIN rail, rotate the top out) and mounting the new PUL6438S before reseating terminal blocks and running Checkout.
Documents and quotation
The Spyder Lon product data (63-2685) serves as the datasheet for PUL6438S. Please send the part number PUL6438S, quantity and delivery point in Oman or the GCC with your RFQ, and tell us if you need a -ILC licensing suffix.
Selection Notes for the Honeywell PUL6438S
When comparing the Honeywell PUL6438S with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the Honeywell controllers & data acquisition range and confirm the correct order code before you commit.
Other Models in the Spyder Lon Unitary Range
Seven Star LLC supplies models from the Spyder Lon Unitary range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell PUL1012S Spyder Lon Unitary Programmable Controller | Controllers & Data Acquisition | View details |
| Honeywell PUL4024S Spyder Lon Unitary Controller 4 UI 2 AO 4 DO | Controllers & Data Acquisition | View details |
| Honeywell PUL6438S Spyder Lon Unitary Controller 6 UI 4 DI 8 DO | Controllers & Data Acquisition | You are viewing this model |
Datasheets & Documents
- Datasheet Honeywell PUL6438S Spyder Lon Unitary Controller 6 UI 4 DI 8 DO Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell PUL6438S Spyder Lon Unitary Controller 6
Answers from our engineering team on installation, compatibility and integration.
01How many digital inputs does the Honeywell PUL6438S have?
It has four digital inputs for dry contacts, plus six universal inputs, three analog outputs and eight Triac outputs.
02What is the DI threshold on PUL6438S?
Open circuit above 3,000 ohm reads False and closed circuit below 500 ohm reads True; open-circuit voltage up to 30 Vdc.
03Is PUL6438S the same as the PUL6438SR?
No. The datasheet 63-2685 covers PUL6438S only; verify any relay-output version against its own literature.
04Does PUL6438S offer a pulse-meter input?
No. The pulse-input footnote lists PUL1012S, PUL4024S, PVL4022AS and PVL4024NS but not this model.
05What power does PUL6438S draw?
The controller alone is 5 VA maximum; the supply must supply 20 to 30 Vac and the total with loads is limited to 100 VA.