Brand: Honeywell
Honeywell UDC3200 1/4 DIN Controller with Math Functions
Description
Honeywell UDC3200 dual-input digital controller with math functions overview
The Honeywell UDC3200 is a 1/4 DIN panel controller built for loops that need more than one measurement. It has two universal analog inputs, a set of pre-configured math algorithms and Accutune III tuning with fuzzy logic overshoot suppression. The manufacturer describes it as the step up from the UDC2500 when an application needs a second universal input or a calculated process variable.
The first input is the process variable input and accepts thermocouple, RTD, Radiamatic and linear actuations. The optional second input is isolated and accepts the same actuations, or it provides the slidewire input used for position proportional control of a motor-driven valve. Cold junction compensation is built in for thermocouples, and sensor break action can be set to upscale, downscale or failsafe from the keypad.
This page summarises the manufacturer documentation for the Honeywell UDC3200 for buyers in Oman and the GCC. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Key features of the UDC3200
The following features are taken from the manufacturer specification for the UDC3200.
- Two universal analog inputs with a typical accuracy of 0.20 percent of full scale and typical 16-bit resolution, both sampled six times per second (every 166 ms).
- Math algorithms for ratio and bias, feedforward summer, feedforward multiplier, weighted average, summer and subtractor, multiplier and divider, and input high or low select.
- Up to five analog and digital outputs, including current, relay, solid state relay, dual relay and open collector types, plus a 30 V dc transmitter power output.
- Two digital inputs for dry contact functions such as local setpoint selection, manual mode, PID set 2, timer start and tuning start.
- Three local setpoints, a timer, setpoint rate and optional ramp and soak programming.
- Optional RS422/485 Modbus RTU or Ethernet 10Base-T Modbus TCP/IP communication, with an infrared port for PC or Pocket PC configuration.
- Position proportional control, using two relays and the second input as a slidewire feedback, and three position step control without feedback.
- NEMA4X and IP66 front face protection, multilanguage prompts and jumper-free field upgrade of options.
UDC3200 technical specifications
The table lists the main specification of the UDC3200. Option combinations are fixed by the model code, so check the selection guide in the manufacturer literature.
| Parameter | Value |
|---|---|
| Model | UDC3200 |
| Format | 1/4 DIN panel mount |
| Analog inputs | One or two universal inputs |
| Input accuracy | 0.20 percent of full scale typical, field calibration to 0.05 percent |
| Resolution and sampling | 16-bit typical, six samples per second (166 ms) |
| Input types | Thermocouple, RTD, Radiamatic, mV, mA and volts |
| Digital filter | 0 to 120 seconds |
| Output types | Current, relay 5 A, dual relay 2 A, solid state relay 1 A, open collector |
| Maximum outputs | Five analog and digital outputs |
| Digital inputs | Two isolated dry-contact inputs (the second current output and second digital input cannot both be used) |
| Math functions | Ratio and bias, feedforward, weighted average, summer, multiplier and divider, high or low select |
| Communications | RS422/485 Modbus RTU, Ethernet 10Base-T Modbus TCP/IP, infrared |
| Power supply | 90 to 264 V ac, 50/60 Hz; 24 V ac/dc optional |
| Power consumption | 20 VA maximum (ac), 15 VA maximum (24 V) |
| Operating temperature | 0 to 55 degC operative limits |
| Depth and weight | 114 mm behind panel, 1.3 kg |
| Front face | NEMA4X and IP66 with screws |
Typical applications in Oman and the GCC
Because the UDC3200 can combine two measurements, it suits loops where the controlled value is calculated or where a position-proportional valve is used. Typical uses in Oman and the GCC include the following.
- Oil and gas: ratio control of fuel and air on fired heaters, blending and dosing skids, and heated sample conditioning systems.
- Utilities and power: steam and hot water temperature loops with a motor-driven valve using position proportional control.
- Water and desalination: chemical dosing with ratio control from a flow signal on the second input.
- Manufacturing: kilns, ovens and reactors that need a weighted average of two sensors or a high select between them for safety.
Selection and compatibility notes for the UDC3200
Pick the UDC3200 when a single loop needs a second input, a calculated variable or a slidewire feedback. If only one analog input is needed, the UDC2500 is the simpler option, and if two independent loops or cascade control are needed, the UDC3500 is the next model in the same family.
Confirm the input type for each channel, the output form for the final element and the communication option. Note that the second current output and the second digital input cannot be used together. For motor-driven valves, position proportional control needs two relays and the optional second input, whereas three position step control needs no feedback signal.
Installation and commissioning of the UDC3200
Mount and wire the UDC3200 according to the manufacturer manual.
- Use a 1/4 DIN panel cutout with 114 mm of space behind the panel and fit all four corner screws when the NEMA4X rating is required.
- Keep input wiring shielded and separate from heater and motor power cables.
- Configure inputs and the math algorithm from the keypad or by infrared with the PC software, then test each input before closing the loop.
- Run Accutune III at normal operating load and save the configuration file for later replacement.
Maintenance and service life
The UDC3200 needs little routine care. Wipe the front face with a damp cloth, check terminal tightness at planned shutdowns, and verify input accuracy against a reference source on your normal calibration schedule. The infrared interface lets a technician upload the working configuration without opening the panel, which makes it practical to keep a clean backup of every unit.
Related products and ordering notes
Related Honeywell controllers available on request include the UDC2500, UDC3500 and UDC2800. Please provide the complete model code with input, output and option digits so Seven Star LLC can quote the exact configuration.
UDC3200 questions in brief
Common questions about the UDC3200 concern its second input, math functions and communication. The controller offers two universal inputs, built-in math algorithms and optional Modbus or Ethernet. The answers below summarise the key points.
Documents and quotation
The manufacturer datasheet for the UDC3200 is available from Seven Star LLC with this listing when it is attached, and it should be read together with the installation manual before any engineering decision. To request a quotation, send an RFQ that states the part number UDC3200, the quantity, the delivery location and, where relevant, the options you need. Seven Star LLC replies with availability and lead time; no price is published on this page.
Other Models in the UDC Range
Seven Star LLC supplies models from the UDC range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell UDC2500 1/4 DIN Universal Digital Controller | Controllers & Data Acquisition | View details |
| Honeywell UDC3200 1/4 DIN Controller with Math Functions | Controllers & Data Acquisition | You are viewing this model |
Datasheets & Documents
- Datasheet Honeywell UDC3200 1/4 DIN Controller with Math Functions Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell UDC3200 1/4 DIN Controller with Math
Answers from our engineering team on installation, compatibility and integration.
01How many analog inputs does the UDC3200 have?
The UDC3200 has one universal process input and an optional isolated second input that accepts the same actuations or serves as a slidewire input.
02Which math functions are available on the UDC3200?
The manufacturer lists ratio and bias, feedforward summer, feedforward multiplier, weighted average, summer and subtractor, multiplier and divider, and high or low select.
03What accuracy does the UDC3200 offer?
Typical accuracy is 0.20 percent of full scale with 16-bit resolution, and both inputs are sampled six times per second.
04Can the UDC3200 control a motor-driven valve?
Yes. Position proportional control uses two relays and the optional second input for slidewire feedback, and three position step control works without feedback.
05How can I request a quotation for the UDC3200?
Send an RFQ with the full model code, quantity and delivery location. Seven Star LLC will reply with availability and lead time; this page shows no price.