Brand:

Honeywell 8C-PCNT03 Series 8 C300 Controller Module

Description

What Honeywell 8C-PCNT03 is

Honeywell 8C-PCNT03 is the Series 8 C300 controller module, the processing core of the Experion Series 8 platform. It deterministically runs control strategies and batch operations, talks to Series 8 I/O over two redundant I/O links, and hosts custom applications, all inside one compact module that needs no additional interface or communication card. The module plugs into an input/output termination assembly, which in this family is 8C-TCNTA1. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; the notes below are a plain-language reading of the manufacturer’s Series 8 Controller and I/O Specification, so engineers can confirm the part before issuing an RFQ.

The 8C prefix matters. The platform document states that the 8C designation marks the conformally coated version, which meets the G3 level of the ISA S71.04 corrosion standard, a relevant detail for coastal plants and sour-gas facilities in the region.

Where 8C-PCNT03 sits in the C300 family

Revision history matters for spares. The specification states that the earlier 8C-PCNT02 part number is replaced by 8C-PCNT03, and that the new controller is compatible with all current and previous PC and LX releases. A user holding an 8C-PCNT02 in a spares list can therefore read the note and see that 8C-PCNT03 is the part that the manufacturer lists today. Comparing the two on a purchase order is straightforward: the model number changes, while the IOTA 8C-TCNTA1, the redundancy cable 51305980-836 and the optional memory backup parts stay the same in the model table.

Parameter Value
Model 8C-PCNT03, Series 8 C300 Controller, coated
IOTA 8C-TCNTA1, 220 mm height by 120 mm width
Redundancy cable 51305980-836
Replaces 8C-PCNT02
Processor PowerPC 8270, 400 MHz, 32 bit
Program memory 16 MB
Power 24 V supplied through cables from the Series 8 power system
Programming Function Block Design through Experion Control Builder
I/O links 2 links, each configurable for Series 8 I/O, 750 kbps
I/O modules 80 I/O units per controller, 40 per I/O link
Maximum I/O per controller 2560
Uplink Dual FTE ports at 100 Mbps
Execution units 5500
Tagged objects 4095
Memory units 16000
Execution period 50 msec to 2000 msec per control strategy
RAM retention 50 hours with the optional rechargeable battery pack

Key capabilities of 8C-PCNT03

  • Module removal and insertion under power are supported, so the electronics can be changed without taking the IOTA down.
  • Redundant operation uses a second identical controller on its own IOTA joined by the redundancy cable, with the design described as having no single point of failure for the I/O modules, termination and communication links.
  • Peer-to-peer communication with other Series 8 C300 controllers, C200 and ControlEdge UOC controllers over Fault Tolerant Ethernet.
  • Third-party connectivity: a Modbus master function, Modbus TCP devices through the PCDI function block, Ethernet/IP peer to peer, Foundation Fieldbus through a Fieldbus Interface Module and Profibus DP through a Profibus Gateway Module.
  • A broad function block library, including PID variants, ratio control, flow compensation, totalizer and 2oo3 voting logic.

Environmental and approval data for 8C-PCNT03

The platform operating limits are 0 to +50 degrees C external and 0 to +60 degrees C internal for a standard 2000 mm cabinet with the doors closed, with 5 to 95 percent relative humidity, non-condensing. Storage and transport tolerates -40 to 85 degrees C. Series 8 hardware is rated as normally non-sparking for Zone 2 with a T4 temperature class, and approvals listed include FM, CSA, ATEX (II 3G Ex nA IIC T4 GC) and IECEx. The installation notes ask for an enclosure with at least IP54 protection and an area of Pollution Degree 2 or better.

Typical uses of 8C-PCNT03 in Oman and GCC plants

A C300 sits behind many refinery units, gas processing trains, power station auxiliaries and large water treatment plants because one controller can address 80 I/O units. Operators typically find it when an Experion cabinet in an older Series 8 or LX system needs a replacement controller, or when an expansion adds another controller node to the FTE network. In a petrochemical train, one redundant pair may run the furnace, compressor anti-surge and utility loops while separate pairs handle each additional unit.

Selection, redundancy and memory backup for 8C-PCNT03

Plan the order as a set. A single 8C-PCNT03 needs one 8C-TCNTA1 IOTA; a redundant pair needs two modules, two IOTAs and the 51305980-836 cable. Where the process should survive a power interruption with a retained memory image, the specification lists the 51454475-100 Series 8 C300 RAM Charger Module, with 51202330-300 (30 inch) and 51202330-200 (84 inch) cables. The 24 V supply comes from Series 8 power supply modules such as 8U-PWSP02-CN, 8U-PWSP04 or 8U-PWSP05, each described as 24 VDC at 20 A.

Commissioning 8C-PCNT03

Set the FTE device index switches on the IOTA before the module is inserted, connect both FTE cables and the two I/O link connectors, and load the control strategy from Control Builder. The IOTA holds only passive parts such as the address switches and cable connectors, so most faults trace to configuration or cabling rather than to the base plate. For a redundant pair, verify the private redundancy cable run and the synchronization status on both modules before putting loops in automatic.

Care and replacement of 8C-PCNT03

Check the status display and the FTE link indicators during routine rounds, review cabinet temperature against the 60 degrees C internal limit and note that rechargeable memory backup packs age, so the manufacturer’s transport notes on lithium batteries apply when shipping. Because insertion under power is supported, a spare can be swapped in on a redundant pair during operation, but follow the Experion procedures for controller replacement.

Questions answered on this page

The FAQ below covers the IOTA pairing, the replaced part number, the I/O capacity and the redundancy parts.

Documents and quotation

The Series 8 Controller and I/O Specification is attached as the datasheet for 8C-PCNT03. To request a quote, send the part number 8C-PCNT03, the quantity, whether the IOTA 8C-TCNTA1 and the redundancy cable are also needed, and your delivery location. Our team will respond with availability.

Datasheets & Documents
  • PDF Datasheet Honeywell 8C-PCNT03 Series 8 Controller and I/O Specification Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell 8C-PCNT03 Series 8 C300 Controller Module

Answers from our engineering team on installation, compatibility and integration.

01Which IOTA does Honeywell 8C-PCNT03 use?
The specification lists 8C-TCNTA1, the Series 8 C300 controller I/O termination assembly, coated, as the IOTA for the controller module.
02Does 8C-PCNT03 replace an older part number?
Yes. The specification states that 8C-PCNT02 is replaced by 8C-PCNT03 and that the new controller is compatible with all current and previous PC and LX releases.
03How many I/O units can one 8C-PCNT03 support?
Up to 80 I/O units per controller and 40 per I/O link, with a maximum of 2560 I/Os per controller, running over two I/O links at 750 kbps.
04What parts are needed for a redundant 8C-PCNT03 pair?
Two controller modules, two IOTAs and the redundancy cable 51305980-836, as stated in the model number notes.
05How do I request 8C-PCNT03 from Seven Star LLC?
Send the part number 8C-PCNT03, quantity and delivery location; Seven Star LLC is an independent supplier and will reply with availability.