- Automation & ControlView all 3,044 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Honeywell
Honeywell T7350H1009 Commercial Programmable Thermostat LONWORKS
Description
Honeywell T7350H1009 commercial programmable thermostat with LONWORKS
Honeywell T7350H1009 is the networked version of the T7350 commercial programmable thermostat for conventional and heat-pump equipment. It keeps the T7350D hardware features, namely humidity, occupancy, outdoor and discharge-air capability, and adds an FTT LONWORKS connection so the thermostat can report and accept values from a building automation system.
The data on this page is drawn from the Honeywell T7350 product data, form 63-2605. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
What the datasheet table says about this model
Table 1 of the manufacturer data lists T7350H1009 in the same row as T7350D for stage capability: a maximum of 3 heat stages with 2 in heat-pump mode and 3 cool stages with 4 in heat-pump mode. Features are humidity, occupancy, outdoor and discharge air capability. The auxiliary relay on this model is listed as Isolated, and LONWORKS capability is Yes. All models are down-selectable, so an installer can set fewer stages than the maximum, and one extra stage of heat or cool can be configured using the auxiliary relay on the A, B models.
T7350H1009 specification table
| Parameter | Value |
|---|---|
| Model | T7350H1009 |
| Application | Conventional or heat pump, single zone |
| Maximum stages | Heat 3 (2 on heat pump); cool 3 (4 on heat pump) |
| Auxiliary relay | Isolated |
| Network | LONWORKS, free topology transceiver; LonMark profile 8500_20 Space Comfort Controller, object 8504 Rooftop |
| Program ID | 80:00:0C:55:04:03:04:2E |
| Supply | 24 Vac, 50/60 Hz (20 to 30 Vac), 5 VA maximum without load |
| Relay outputs at 30 Vac | 1.5 A running, 7.5 A inrush, N.O. SPST |
| Inputs | Space 20K ohm; humidity 0 to 10 Vdc; outdoor 3000 ohm PTC; discharge air 20K ohm; occupancy dry contact 30 Vdc at 1 mA |
| Operating ambient | 30 to 110 F (minus 1 to 43 C); shipping minus 30 to 150 F |
| Setpoint range | Heating 40 to 90 F (4 to 32 C); cooling 45 to 99 F (7 to 37 C); deadband 2 F (1 C) |
| Display accuracy / clock accuracy | Plus or minus 1 F (1 C) / plus or minus 1 minute per month at 77 F |
| Humidity rating | 5 to 90 percent RH, non-condensing |
| Finish / batteries | Trident White / none required |
| Power-loss memory | Programmed times and temperatures retained; clock and day kept at least 48 hours after 5 minutes of powered operation |
Scheduling and control behaviour
The thermostat offers 7-day programming with two Occupied and two Not Occupied periods per day, separate heating and cooling setpoints for each period and P+I+D control to limit temperature swing. A recovery ramp starts equipment early based on building load. Through TStatSpec software or a PDA the installer unlocks a 365 day clock with holiday programming, automatic daylight saving changes, dehumidification limit control, an extra standby period, sequential start, discharge high and low limits and ambient lockout with an outdoor sensor.
How T7350H1009 differs from other T7350 models
The T7350A is the basic model with one stage and no outdoor or humidity capability; T7350B adds two stages and outdoor and discharge-air capability; T7350D adds humidity and occupancy with three stages; T7350M is modulating without network capability. T7350H1009 is therefore the networked D-style unit. Against T7350H1017, which is the modulating networked unit with a 4 to 20 mA output, T7350H1009 drives only relays. The networked units can also time-schedule up to 119 network-connected XL10 and XL15c devices and act as the network master clock.
Network functions
With the H models the thermostat accepts outdoor temperature, an occupancy sensor, electric demand shed or restore, room temperature and humidity over the network. It reports to a workstation or a Command Display S7760, supports remote override, schedule and setpoint changes, and offers Network Manual Mode to switch outputs. Interoperability is LonMark version 3.3. Honeywell provides a LonMark plug-in to ease third party configuration. These are reasons to choose T7350H1009 for upgrade work in buildings already on an Echelon bus.
Mounting and commissioning
Terminal labelling on the T7350H subbase follows the pattern RC and RH for the cooling and heating transformers (with a factory jumper for single-transformer systems), X for common, W1 or O/B for stage 1 heat or the heat-pump changeover, W2, Y1 and Y2, G for the fan, AS for the discharge-air sensor, OS for the outdoor sensor, T3 to T7 for TR20 series remote sensors, plus the auxiliary relay connections. Wire of 18 gauge is the maximum and recommended size, and nothing smaller than 22 gauge should be used. The thermostat plugs onto a subbase that mounts on the wall with two 5/8 in number 6-32 screws or on an outlet box with sheet metal screws. Place remote sensors about 5 ft (1.5 m) above the floor in moving air; averaging uses four or nine sensors. Defaults are 70 F (21 C) heating and 75 F (24 C) cooling when occupied, 55 F (13 C) and 85 F (29 C) when not occupied, 67 F (19 C) and 78 F (26 C) in standby. Leave room below the unit for the TIM cable and disconnect that cable before opening the cover, since the manual warns that doing otherwise can damage the TIM connection beyond repair. The subbase can be mounted horizontally or vertically, but when the internal sensor is used the thermostat should lie horizontal with the LCD facing up, whereas with remote sensors the orientation does not matter. For a wall of drywall, drill 3/16 in (4.76 mm) holes and tap in the supplied anchors; for plaster or wood use 7/32 in (5.56 mm) holes.
Maintenance and accessories
No batteries are needed. Accessories named in the datasheet include C7041B, C7041C and C7041J duct sensors, C7770A, outdoor sensors C7089A, C7170A and C7031G2014, remote sensors C7772A, TR21, TR22, TR23, TR24 and T7771, H7625 and H7635 humidity sensors, the 209541B FTT termination module and TG512 Versaguard guards. Keep these in mind when quoting T7350H1009.
Documents and quotation
The Honeywell T7350 product data (form 63-2605) is the datasheet for T7350H1009. For an RFQ, send the part number T7350H1009, quantity, destination and any accessories required.
Other Models in the T7350 Range
Seven Star LLC supplies models from the T7350 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell T7350H1009 Commercial Programmable Thermostat LONWORKS | Controllers & Data Acquisition | You are viewing this model |
| Honeywell T7350H1017 Modulating Programmable Thermostat | Controllers & Data Acquisition | View details |
Datasheets & Documents
- Datasheet Honeywell T7350H1009 Commercial Programmable Thermostat LONWORKS Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell T7350H1009 Commercial Programmable
Answers from our engineering team on installation, compatibility and integration.
01Is the Honeywell T7350H1009 a LONWORKS thermostat?
Yes. The H models provide connection terminals for the LONWORKS bus, a network jack and a service pin pushbutton.
02How many stages does T7350H1009 support?
Up to three heat and three cool stages conventionally, or two heat and four cool stages on a heat pump, per Table 1.
03What type of auxiliary relay does T7350H1009 have?
Table 1 of the manufacturer data lists an Isolated auxiliary relay for this model.
04What is the heating setpoint range of T7350H1009?
Heating can be set from 40 to 90 F (4 to 32 C) and cooling from 45 to 99 F (7 to 37 C), with a 2 F deadband.
05Does T7350H1009 need batteries?
No batteries are required, and the clock holds at least 48 hours after the thermostat has been powered for five minutes.


















Reviews
There are no reviews yet.