Brand:

Honeywell 2106B1410 Sensepoint Cl2 Sensor 0-5 ppm M20

Description

Chlorine detection is one of the jobs where the construction of the sensor matters as much as its range. Honeywell 2106B1410 is the Sensepoint chlorine head for 0 to 5 ppm with an M20 thread. Honeywell’s literature explains that the intrinsically safe sensing end of the Sensepoint design removes the need for a sinter, which allows quick access for sticky gases such as chlorine and ammonia, and that gives the 2106B1410 a response that would otherwise be difficult to achieve with a filtered cell.

Reading the 2106B1410 datasheet

  • Gas and range: chlorine, 0 to 5 ppm; the sister head 2106B1411 covers 0 to 15 ppm.
  • Thread: M20; M25 versions are 2106B1510 and 2106B1511, and the 15 ppm NPT version is 2106B1711.
  • Signal: loop powered 4 to 20 mA, with 18 to 30 VDC supply and 0.9 W maximum.
  • Operating temperature: -20 to +50 degrees C; humidity 20 to 90 percent RH continuous, 10 to 99 percent intermittent.
  • Warm-up: less than 5 minutes.
  • Response: T20 less than 10 s, T50 less than 20 s, T90 less than 105 s.
  • Typical life: 18 months; storage life six months.
  • Weight 185 g; PPS body; IP65, IP67 with the weather protection fitted.

Stability figures that matter for 2106B1410

Parameter Value
Zero stability with time Less than +/-2 percent fsd per year
Zero stability with temperature Less than +/-2 percent fsd
Zero stability with humidity Less than +/-2 percent fsd
Span stability with time Less than 10 percent fsd per year
Span stability with temperature Less than 40 percent fsd
Span stability with humidity Less than +/-2 percent fsd
Linearity Less than 5 percent fsd

The large temperature term for span reflects the physics of chlorine cells and is the reason to calibrate near the real service temperature. Plants in Oman with sunlit outdoor dosing skids should shade the head or fit the weather protection to keep sensor temperature inside the -20 to +50 degrees C window.

2106B1410 in water treatment and chemicals

Chlorine at low ppm is a classic hazard in potable-water chlorination rooms, swimming pool plant rooms, desalination post-treatment, cooling-water dosing and chlor-alkali or bleach production. A 0 to 5 ppm span places the low alarm at a fraction of a ppm. On the XCD RTD transmitter the 5 ppm span defaults to a low alarm of 0.5 ppm and a high alarm of 2.0 ppm, while the 15 ppm span defaults to 1.5 and 6.0 ppm.

A practical consequence of the figures above is how the 2106B1410 should be commissioned. With a T90 of up to 105 seconds the head will not reflect a short puff of gas the way a catalytic LEL head does, so alarm delays in the control system should be short or zero, and function tests with span gas should allow at least two minutes of exposure before judging the response. Honeywell’s table lists T20 under 10 seconds, which means the first rise appears quickly even though the final value takes longer, and that early rise is what a trend display will show during a real release.

The chlorine cell is also sensitive to the electrical environment in a sense that is easy to overlook: the loop is a two-wire 4 to 20 mA circuit supplied at 18 to 30 VDC, so a long run of thin cable can drop the supply below the minimum under full alarm current. Calculate cable length with the actual cable resistance and the minimum supply your controller guarantees. The head draws up to 0.9 W, which is modest, but the arithmetic still needs to be done once for every new route.

Installation of 2106B1410

Fit the head to an Ex d or Ex e junction box through the M20 entry, connect red for positive and blue for negative with the screen at one end, and fit the weatherproof cap outdoors. Chlorine is denser than air, so placement in the lower part of a room is the usual practice in hazard studies; the final height is a site decision. Honeywell’s accessory list for the family includes a collecting cone for lighter-than-air gases, a flow adaptor and a duct mounting kit.

Commissioning and cell exchange

Wait out the five-minute warm-up and calibrate with a chlorine span gas through the toxic calibration kit 2106B2114. Because the cell life is 18 months, the Cl2 electrochemical exchange kit 2106B1547 is listed for replacement. Use a calibration log; the span drift figure is large enough that a missed interval can matter.

Sites that already operate Sensepoint toxic heads on one controller usually keep a spare for each gas rather than a universal one. For chlorine that means holding either a full head, 2106B1410, or the cell exchange kit 2106B1547 if the metal housing is in good condition. Honeywell notes in its datasheet that stored sensors are good for six months, so spares should be dated and rotated rather than bought in bulk. When ordering from outside the manufacturer’s channel, quote the complete part number including the final digits, because 2106B1410 and 2106B1411 look nearly identical on a label but cover different spans, 0 to 5 ppm and 0 to 15 ppm.

How 2106B1410 differs from other Sensepoint toxic heads

Compared with the H2S head 2106B1400 it has a longer warm-up, 5 minutes against 3, a much slower T90 of under 105 seconds against under 40, and a shorter life of 18 months against 2 years. Compared with the CO head 2106B1405 it tolerates the same upper temperature of +50 degrees C but gives up the larger temperature-related span stability.

Documents and quotation

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The Sensepoint datasheet can accompany your quotation. Please send an RFQ naming 2106B1410, quantity, delivery location and the junction box thread.

Datasheets & Documents
  • PDF Datasheet Sensepoint Gas Detector Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell 2106B1410 Sensepoint Cl2 Sensor 0-5 ppm

Answers from our engineering team on installation, compatibility and integration.

01What does Honeywell 2106B1410 detect and over what range?
It detects chlorine from 0 to 5 ppm and is the M20-thread Sensepoint chlorine head with a loop-powered 4 to 20 mA output.
02What is the response time of the 2106B1410?
The Sensepoint datasheet lists T20 below 10 seconds, T50 below 20 seconds and T90 below 105 seconds for the chlorine cell.
03What is the default alarm setting for the 5 ppm chlorine span?
When used with an XCD RTD transmitter the 5 ppm span has a default low alarm of 0.5 ppm and a default high alarm of 2.0 ppm.
04How long does the chlorine cell in 2106B1410 last?
Honeywell quotes a typical operating life of 18 months for the chlorine cell and a storage life of six months.
05Which cell exchange kit is listed for chlorine heads?
The Cl2 electrochemical cell exchange kit is listed under part number 2106B1547 in the Sensepoint ordering table.