Endress+Hauser CDC90 Liquiline Control Memosens pH/ORP Automation

Description

CDC90 Liquiline Control: one cabinet that looks after two pH points

Endress+Hauser CDC90, branded Liquiline Control, automates the cleaning, calibration and monitoring of up to two Memosens pH or ORP measuring points. It is a system of control unit, pneumatic control unit, pumps, float switch, canisters for buffers and cleaners, multihoses, an Ethernet switch and a rinsing block, all mounted on a plate and used with a retractable assembly such as the Cleanfit series, which is not included in delivery.

The idea is workplace safety and reproducibility: nobody has to climb a tank platform or enter a hazardous area to pull an electrode, and buffers and cleaner are dosed by a hydraulic system designed to limit consumption. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

CDC90 data from the technical information

Parameter Value
Function Cleans, calibrates and monitors up to two Memosens pH, ORP or combined sensors
Programs Clean, clean and calibrate, assembly retraction to measuring and service positions; all customisable, plus free programs
Calibration pH glass and ISFET sensors; one-point and two-point options
Inputs Memosens digital sensor inputs, digital inputs, NAMUR inputs on pneumatic unit, 2 x 0/4 to 20 mA standard, 0 to 30 V DC
Communication 0/4 to 20 mA, PROFIBUS DP, Modbus TCP, EtherNet/IP, PROFINET (via Modbus TCP gateway), web server
Supply 100 to 230 V AC, 50/60 Hz, up to 50 VA
Mains cable 3 x 0.75 mm2 to 10 m; 3 x 1.5 mm2 to 20 m
Ambient / storage 0 to 45 degrees C / minus 20 to 70 degrees C; 10 to 90 percent humidity non-condensing; altitude under 2000 m
Protection CDC90 control unit IP66 Type 4X; pneumatic control unit IP54 Type 12; indoor use only
Weight About 71 kg complete on mounting plate
Materials PC module housing, TPE keys, 1.4301 cable rail, PE canisters, PP shelf, PVDF D6/8 mm hose couplings

Reliability features

A status light shows device status according to NAMUR, and the colour display lists the active and scheduled programs along with current measured values. Level and consumption indicators show how much buffer or cleaner remains. If a calibration result is outside tolerance, the system rejects it, so a bad buffer cannot silently shift the measurement.

How CDC90 differs from CPC310 and a plain transmitter

CPC310 Topcal S is the earlier system built around the Mycom S CPM153 transmitter and the CPG310, with PROFIBUS PA and HART and the option of hazardous-area versions. CDC90 works purely with Memosens digital sensors, serves two measuring points from one cabinet, speaks Ethernet-based protocols and is limited to indoor installation at 0 to 45 degrees C. A Liquiline CM44x transmitter measures but does not dose buffer or move assemblies; CDC90 adds the hydraulics and pneumatics.

Planning an installation

  • Provide compressed air, rinse water and mains power at the mounting location; the datasheet lists a D12 water hose barb in PP.
  • Mount indoors, away from wet areas, below 2000 m altitude.
  • Use the Ethernet kit with M12 to RJ45 plug for gateway communication; a 3 m cable is included.
  • Install a retractable assembly such as the Cleanfit series and run air, water and electrical lines to it.
  • Choose the communication option and gateway before ordering.

Operating CDC90 from the touchscreen

The CDC90 is operated from a touchscreen with soft keys for program handling, and remote operation from the control centre is possible. Hose ratings are stated: medium hoses up to 6 bar, the pilot valve manifold up to 10 bar and the pressure switch up to 12 bar. Pumps A, B and C convey liquids, a rinsing block provides air, and the assembly inlet and outlet use PVDF hose couplings of 6 by 8 mm. The multihoses M1 to M4 distribute media to the two measuring points.

Because the system rejects calibration values outside the tolerance, and shows both level and consumption of buffer and cleaner, the maintenance person knows when to refill canisters rather than discovering an empty bottle after a failed calibration.

Applications in Oman and the Gulf

Neutralisation, scrubber, desalination post-treatment and effluent control loops across the GCC place pH sensors in awkward or hazardous spots and need dependable two-point calibration. One CDC90 cabinet in a nearby non-hazardous room can serve two such points, send alarms to the control room and keep the electrodes clean enough to hold their slope.

CDC90 questions answered briefly

How many sensors does Endress+Hauser CDC90 handle? Up to two Memosens pH, ORP or combined sensors, each with its own configurable cleaning and calibration intervals.

Which communication options does CDC90 support? Analog 0/4 to 20 mA plus PROFIBUS DP, Modbus TCP, EtherNet/IP, PROFINET and a web server, with an optional gateway for fieldbus conversion.

Can CDC90 be installed outdoors? No, the datasheet says it is for indoor use only; the control unit is IP66 Type 4X, the pneumatic unit IP54 Type 12 and the ambient range is 0 to 45 degrees C.

What power does CDC90 require? 100 to 230 V AC, 50 or 60 Hz, up to 50 VA, with mains within plus or minus 10 percent.

How heavy is the complete CDC90? About 71 kg for the complete device on its mounting plate.

Documents and quotation

The datasheet for CDC90 is attached. Send an RFQ with CDC90, the communication protocol, number of sensors and assembly type, and the quantity. Please also tell us the mains voltage on site and whether a fieldbus gateway is needed, because those choices are fixed in the order code and we want the cabinet to match your control system before it ships. Tell us which transmitter, assembly and sensor are already installed so we can check the match against the datasheet, and whether the pressure-reducing and hose accessories should be included.

Other Models in the Automation Range

Seven Star LLC supplies models from the Automation range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser CPC310 Topcal S Automatic pH Cleaning and CalibrationLiquid Analytical SystemsView details
Endress+Hauser CDC90 Liquiline Control Memosens pH/ORP AutomationLiquid Analytical SystemsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Endress+Hauser CDC90 Liquiline Control Memosens pH/ORP Automation Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser CDC90 Liquiline Control Memosens

Answers from our engineering team on installation, compatibility and integration.

01How many sensors does Endress+Hauser CDC90 handle?
Up to two Memosens pH, ORP or combined sensors, each with its own configurable cleaning and calibration intervals.
02Which communication options does CDC90 support?
Analog 0/4 to 20 mA plus PROFIBUS DP, Modbus TCP, EtherNet/IP, PROFINET and a web server, with an optional gateway for fieldbus conversion.
03Can CDC90 be installed outdoors?
No, the datasheet says it is for indoor use only; the control unit is IP66 Type 4X, the pneumatic unit IP54 Type 12 and the ambient range is 0 to 45 degrees C.
04What power does CDC90 require?
100 to 230 V AC, 50 or 60 Hz, up to 50 VA, with mains within plus or minus 10 percent.
05How heavy is the complete CDC90?
About 71 kg for the complete device on its mounting plate.