- Automation & ControlView all 3,006 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: ABB
ABB 1SVR427035R2000 CP-E 48/10.0 Power Supply 48 V DC, 10 A, 480 W
Description
ABB 1SVR427035R2000: 480 W of 48 V DC with active power factor correction
ABB 1SVR427035R2000 is the CP-E 48/10.0, the largest 48 V unit in the CP-E family. It converts a single wide AC range of 90 to 264 V (115 or 230 V nominal) into 48 V DC at 10 A, which is 480 W, and does so with active power factor correction: 0.99 at 115 V and 0.97 at 230 V. Active PFC keeps the input current close to sinusoidal, which matters when several supplies share a feeder or a small generator.
Units like this serve 48 V loads that are too large for a 240 W supply: telecom rectifier replacements, larger PoE midspan banks, DC motor-drive control stages and battery floats for 48 V strings. The output adjusts from 47 to 56 V DC.
Start-up behaviour is specified too: the 48 V output comes up within 1 s at rated current and with 7000 microfarad of capacitance within 1.5 s, the rise time is at most 150 ms at rated current (500 ms with 7000 microfarad) and the fall time at most 150 ms. These numbers decide whether a downstream controller sees a clean ramp or a slow one.
Heat is the practical limit on 1SVR427035R2000: typical power dissipation is 60 W at full load, so a cabinet with several such units needs ventilation planning, and the derating starts above 55 degrees C rather than 60 degrees C. Output power can be raised by connecting up to three units in parallel, which would give up to 1.44 kW at 48 V DC with the load staying between 0.1 and 0.9 of the rated current per unit.
Key points of 1SVR427035R2000
- 480 W output at 48 V DC, 10 A up to 55 degrees C ambient.
- Input 90-264 V AC, 47-63 Hz, with active PFC.
- Typical efficiency 89 percent; typical dissipation 60 W.
- Parallel up to 3 devices, series up to 2 devices.
- Starts capacitive loads up to 7000 microfarad.
- Class I Div. 2 hazardous locations approval listed.
1SVR427035R2000 data summary
| Order code | 1SVR427035R2000 |
|---|---|
| Type | CP-E 48/10.0 |
| Input range | 90-264 V AC |
| Input current at 115 V AC | 4.9 A |
| Power consumption | 528 W |
| Inrush at 115 V AC | 25 A (max. 5 ms) |
| Buffering at 115 V AC | min. 25 ms |
| Internal fuse | 10 A slow-acting, 250 V AC |
| PFC | active, 0.99 / 0.97 |
| Output | 48 V DC / 10 A / 480 W |
| Adjustment range | 47-56 V DC |
| Derating above 55 C | 2.5 percent per degree to 70 C |
| Ripple and peaks | 100 mV |
| Efficiency | typ. 89 percent |
| Dimensions (W x H x D) | 175 x 123.6 x 123.6 mm |
| Weight | 1.839 kg |
| Reverse feed resistance | max. 63 V DC |
| Operating temperature | -40 to +70 C; rated load to +55 C |
How 1SVR427035R2000 differs from CP-E 48/5.0 and 24/20.0
Against the 48/5.0, the 48/10.0 doubles current and power and widens the body from 83 mm to 175 mm, while moving from passive PFC (0.7) to active PFC and from a split 115/230 V range to a continuous 90-264 V range. Its full-load temperature limit is 55 degrees C rather than 60 degrees C. Against the 24/20.0, which is also 480 W, this unit carries half the current at twice the voltage. Efficiency is typically 89 percent, one point below the 48/5.0.
Use cases in the GCC
Remote oil and gas sites, microwave repeaters on mountain ridges and hot-climate telecom cabinets frequently rely on 48 V DC. A DIN-rail 480 W supply allows a standard control panel to host the same bus. Active PFC supports installations powered by diesel generators with limited headroom.
Selection notes
Check that the continuous load is at or below 10 A up to 55 degrees C ambient and derate above. With the parallel switch set for parallel operation, the load must remain within 0.1 to 0.9 of the rated current of each unit. Size the output fuse for the short-circuit behaviour, which continues with output power limiting.
Mounting and wiring
The datasheet documents the electromagnetic robustness of the unit: electrostatic discharge immunity at level 4 (15 kV air, 8 kV contact), burst at level 4 (4 kV at 2.5 kHz) and surge at level 3 line-to-line (2 kV) and level 4 line-to-PE (4 kV). The unit is built to IEC/EN 62368-1, pollution degree 2, overvoltage category II, with 3 kV AC isolation between input and output and 1.5 kV AC from input to PE. Housing is metal, typical dissipation is 60 W, capacitive loads of 7000 microfarad can be started, and the output voltage rises within 150 ms at rated current and starts within 1 s.
Mount horizontally on a DIN rail with the input terminals below, keeping 25 mm clear. Connect L, N and PE, protect the supply with a suitable disconnect and wire L+ and L- to the load. Fine-strand cables of 0.2-4 mm2 are stripped 8 mm and tightened to 1.0 Nm on the input and 0.62 Nm on the output side.
Maintenance
The metal-housed unit has no serviceable parts. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Quick answers about 1SVR427035R2000
What is the output power of 1SVR427035R2000? It delivers 480 W, that is 48 V DC at a rated current of 10 A.
Does 1SVR427035R2000 have power factor correction? Yes, active PFC with 0.99 at 115 V AC and 0.97 at 230 V AC.
What is the input voltage range of 1SVR427035R2000? The single input range is 90 to 264 V AC at 47-63 Hz, with active PFC.
How large is 1SVR427035R2000? 175 mm wide, 123.6 mm high and 123.6 mm deep, weight 1.839 kg.
At what ambient temperature does 1SVR427035R2000 derate? Above 55 degrees C by 2.5 percent per degree up to 70 degrees C.
Documents and quotation
The datasheet for 1SVR427035R2000 is available on this page. To obtain a quotation, send an RFQ with part number 1SVR427035R2000, quantity and the delivery location.
Selection Notes for the ABB 1SVR427035R2000
When comparing the ABB 1SVR427035R2000 with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the ABB power modules range and confirm the correct order code before you commit.
Other Models in the Abb Cp E Range
Seven Star LLC supplies models from the Abb Cp E range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ABB 1SVR427035R2000 CP-E 48/10.0 Power Supply 48 V DC, 10 A, 480 W | Power Modules | You are viewing this model |
| ABB 1SVR427035R1000 CP-E 12/10.0 Power Supply 12 V DC, 10 A, 120 W | Power Modules | View details |
Datasheets & Documents
- Datasheet ABB 1SVR427035R2000 CP-E 48/10.0 Power Supply 48 V DC, 10 A, 480 W Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB 1SVR427035R2000 CP-E 48/10.0 Power Supply 48 V
Answers from our engineering team on installation, compatibility and integration.
01What is the output power of 1SVR427035R2000?
It delivers 480 W, that is 48 V DC at a rated current of 10 A.
02Does 1SVR427035R2000 have power factor correction?
Yes, active PFC with 0.99 at 115 V AC and 0.97 at 230 V AC.
03What is the input voltage range of 1SVR427035R2000?
The single input range is 90 to 264 V AC at 47-63 Hz, with active PFC.
04How large is 1SVR427035R2000?
175 mm wide, 123.6 mm high and 123.6 mm deep, weight 1.839 kg.
05At what ambient temperature does 1SVR427035R2000 derate?
Above 55 degrees C by 2.5 percent per degree up to 70 degrees C.


















Reviews