- Automation & ControlView all 3,006 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: ABB
ABB 1SVR427035R1000 CP-E 12/10.0 Power Supply 12 V DC, 10 A, 120 W
Description
ABB 1SVR427035R1000: a 12 V DC rail power supply with 10 A capacity
Most DIN-rail power supplies are 24 V devices, so the ABB CP-E 12/10.0, order code 1SVR427035R1000, fills a narrower but important niche: 12 V DC loads that need a real 120 W supply. It converts 115 or 230 V AC (auto-selecting between 90-132 V and 180-264 V, or 210-375 V DC) into a regulated 12 V DC output of up to 10 A, adjustable between 11.4 and 14.5 V by a front potentiometer. Typical efficiency is 84 percent, and cooling is by free convection without fans.
Applications for 12 V rails include older radio and telemetry equipment, CCTV and access-control cabinets, some analyser sampling systems and instruments that were designed around lead-acid battery voltage. In such systems 1SVR427035R1000 gives a single replacement point for mains-to-12 V conversion in an industrial cabinet.
One more consideration for 1SVR427035R1000: its ambient range of -35 to +70 degrees C with rated load up to +60 degrees C makes it suitable for cabinets in the Gulf summer, provided the output current is derated by 2.5 percent per degree above 60 degrees C. At 70 degrees C the permitted output is 75 percent, or 7.5 A.
Features of 1SVR427035R1000
- Output 12 V DC, 10 A, 120 W, continuous short-circuit proof.
- Wide input: 90-132 V AC, 180-264 V AC or 210-375 V DC, auto select.
- Ambient range -35 to +70 degrees C, derating of 2.5 percent per degree above 60 degrees C.
- LEDs for output OK and output low, single/parallel switch.
- Parallel connection of up to 3 devices; series connection up to 2 devices.
- Class I, Div. 2 hazardous locations approval listed in the datasheet.
1SVR427035R1000 specification table
| Order code | 1SVR427035R1000 |
|---|---|
| Type | CP-E 12/10.0 |
| Input voltage | 115/230 V AC auto select; 210-375 V DC |
| Frequency | 47-63 Hz |
| Input current at 115 V AC | 2.2 A |
| Inrush at 115 V AC | 24 A (max. 5 ms) |
| Buffering time at 115 V / 230 V | 25 ms / 30 ms |
| Internal fuse | 3.15 A slow-acting, 250 V AC |
| Power factor correction | passive, 0.7 |
| Output voltage / range | 12 V DC / 11.4-14.5 V |
| Output power / current (Ta up to 60 C) | 120 W / 10 A |
| Ripple and switching peaks (20 MHz) | 50 mV |
| Efficiency | typ. 84 percent |
| Dimensions (W x H x D) | 63.2 x 123.6 x 123.6 mm |
| Weight | 0.888 kg |
| Protection | IP20 housing and terminals; class I |
| Insulation input/output | 3 kV AC |
| Operating temperature | -35 to +70 C |
| Terminal capacity | 0.2-4 mm2 |
Where CP-E 12/10.0 sits in the CP-E range
The CP-E family is defined by output voltage and current. At 12 V the choices are 12/10.0 and 12/2.5; at 24 V they run from 0.75 A to 20 A; at 48 V from 0.62 A to 10 A. At 63.2 mm wide the 12/10.0 is the slimmest of the high-current units, compared with 83 mm for the 240 W CP-E 48/5.0. Compared with the CP-E 24/5.0, which also gives 120 W, the 12 V unit carries twice the output current at half the voltage, so cable cross-section matters. Typical efficiency is 84 percent, lower than the 89-90 percent of the 24 V and 48 V types.
Applications in Oman and the GCC
Pumping-station telemetry, remote terminal units with 12 V radios, perimeter CCTV in oil and gas compounds and weather stations around airports and ports are typical consumers. A 10 A 12 V output is large enough for a radio plus camera head plus heater in one cabinet. The wide input range copes with variations on rural feeders in the interior.
Selection and redundancy
Because the voltage is adjustable, you can compensate for line drop to remote loads by setting the output above 12 V, to a maximum of 14.5 V. Parallel operation of up to three devices raises capacity, with the load kept between 0.1 and 0.9 times rated current per device. For true redundancy the CP-A RU redundancy unit (1SVR427071R0000) decouples two units.
Installation and commissioning
Environmental data in the datasheet include operation from -35 to +70 degrees C (rated load up to +60 degrees C), storage from -40 to +85 degrees C, damp heat at 95 percent relative humidity without condensation, vibration of 2 G from 10 to 500 Hz and shock of 15 G for 11 ms. The unit has a metal housing, typical power dissipation of 24 W, capacitive loads up to 7000 microfarad can be started, and the resistance to reverse feed is 18 V DC. Isolation is 3 kV AC between input and output, 1.5 kV AC input to PE and 0.5 kV AC output to PE. Terminals accept 0.2 to 4 mm2 fine-strand with ferrule or 0.2 to 6 mm2 without ferrule, stripped 8 mm and tightened to 1.0 Nm on the input and 0.62 Nm on the output.
Snap the unit on to a 35 mm DIN rail with the input terminals at the bottom, leave at least 25 mm free above and beside it, connect L, N and PE, then wire L+ and L- to the load. Observe polarity and protect the supply line with a suitable disconnecting device. Set the OUTPUT Adjust potentiometer with the load connected and check the green OUTPUT OK LED.
Maintenance
The unit has no user-serviceable parts and is maintenance-free; return it if the internal fuse has blown. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Quick answers about 1SVR427035R1000
What output does 1SVR427035R1000 deliver? 12 V DC at up to 10 A (120 W), adjustable from 11.4 to 14.5 V DC.
What input voltage does 1SVR427035R1000 accept? 115/230 V AC auto select (90-132 V AC and 180-264 V AC) and 210-375 V DC.
What is the efficiency of 1SVR427035R1000? The datasheet gives a typical efficiency of 84 percent at rated load.
Can 1SVR427035R1000 be connected in parallel? Yes, up to three units can be paralleled with the single/parallel switch.
What is the operating temperature of 1SVR427035R1000? -35 to +70 degrees C, with output derating of 2.5 percent per degree above 60 degrees C.
Documents and quotation
The ABB datasheet for 1SVR427035R1000 is available from this page with dimensions and technical data. To request a quotation, send an RFQ with part number 1SVR427035R1000, quantity and the delivery location.
Other Models in the Abb Cp E Range
Seven Star LLC supplies models from the Abb Cp E range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ABB 1SVR427035R2000 CP-E 48/10.0 Power Supply 48 V DC, 10 A, 480 W | Power Modules | View details |
| ABB 1SVR427035R1000 CP-E 12/10.0 Power Supply 12 V DC, 10 A, 120 W | Power Modules | You are viewing this model |
Datasheets & Documents
- Datasheet ABB 1SVR427035R1000 CP-E 12/10.0 Power Supply 12 V DC, 10 A, 120 W Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB 1SVR427035R1000 CP-E 12/10.0 Power Supply 12 V
Answers from our engineering team on installation, compatibility and integration.
01What output does 1SVR427035R1000 deliver?
12 V DC at up to 10 A (120 W), adjustable from 11.4 to 14.5 V DC.
02What input voltage does 1SVR427035R1000 accept?
115/230 V AC auto select (90-132 V AC and 180-264 V AC) and 210-375 V DC.
03What is the efficiency of 1SVR427035R1000?
The datasheet gives a typical efficiency of 84 percent at rated load.
04Can 1SVR427035R1000 be connected in parallel?
Yes, up to three units can be paralleled with the single/parallel switch.
05What is the operating temperature of 1SVR427035R1000?
-35 to +70 degrees C, with output derating of 2.5 percent per degree above 60 degrees C.


















Reviews