Yokogawa YS1310 Indicator with Alarms
Description
Yokogawa YS1310 overview: two-input indicator with alarm outputs
The Yokogawa YS1310 is an input indicator with alarms and two analog inputs. Two loops can be displayed simultaneously, and a high limit, low limit, high-high and low-low alarm can be generated for each input, with AND or OR combinations of alarms output on a total of six contacts.
The basic type of the Yokogawa YS1310 conforms to the DIN short case size, which saves panel space, and complies with CE, FM and CSA standards. Compatible types keep the cutout and depth of earlier Yokogawa models.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list YS1310 so that maintenance, instrumentation and procurement teams can quote the exact model code that appears in the manufacturer documentation.
Key features of YS1310
- Two analog inputs displayed at once, each with four alarm limits.
- Six alarm contacts with AND or OR combinations of arbitrary alarms.
- Full-dot TFT LCD with meter, trend, bar graph, alarm and event displays.
- Parameters can be set from the front panel, without drawing out the internal unit, or by YSS1000 software.
- AC and DC dual power supply (220 to 240 V option must be specified when ordering).
- Dust and splash-proof IP54 faceplate and 250 mm depth for the basic type.
- No battery or capacitor for memory backup.
YS1310 technical specifications
The table below lists values published by the manufacturer for the product family of YS1310. Where a value depends on the ordered configuration, the model and suffix code table in the General Specifications governs.
| Parameter | Value |
|---|---|
| Model | YS1310 indicator with alarms (suffix codes select the type) |
| Basic type | YS1310-10x: 2 analog inputs (1 to 5 V), 6 alarm outputs |
| Basic type with expandable I/O | YS1310-12x: 2 analog inputs, 6 alarm outputs, direct input option |
| Compatible types | YS80 internal unit, EBS and I series, EK and HOMAC, YS80 compatible size with YS100 terminal |
| Alarms per input | High, low, high-high and low-low |
| Alarm contacts | 6, with AND or OR connection |
| Faceplate | IP54 dust and splash-proof (basic type) |
| Depth | 250 mm (basic type) |
Typical applications of YS1310 in Oman and the GCC
- Local indication and alarm of two process variables in a control room panel.
- Interlock and annunciation outputs on boiler, heater and utility panels.
- Replacement of earlier YS series indicators with alarms.
- Dual-variable monitoring where a trend display helps operators.
- Cooling-water, lube-oil and steam condition monitoring.
Panel-mounted single-loop controllers and indicators remain in service for decades in power stations, refineries, desalination plants and process units across Oman and the GCC, often as the last manual-station layer behind a DCS or as stand-alone control on boilers, heaters, dosing and utility loops. Plant owners therefore search for the exact model code, such as YS1310, so that a failed unit can be replaced with one that fits the existing panel cutout and wiring.
Selection and compatibility notes for YS1310
The YS1310 is an indicator rather than a controller, so it has no control output. For PID control, ask about the YS1500 or YS1700. Read the complete model and suffix code from the existing unit to select the correct type and power supply.
The model code of YS1310 is only the beginning, because the suffix codes select the type (basic, expandable I/O, or one of the compatible types for older Yokogawa lines), the power supply, the communication option and optional functions. Send us the full code from the nameplate of the unit being replaced, or the specification you want, and we will compare it with the model and suffix code table in the manufacturer General Specifications before quoting.
Installation and commissioning
Check the panel cutout and depth, wire the two inputs and alarm contacts according to the terminal diagram and confirm the supply type on the nameplate. Set the alarm limits and combinations from the front panel and test each contact.
Check the panel cutout and depth against the type you ordered, wire the input, output and power terminals according to the manufacturer terminal diagram, and verify the power supply type on the nameplate before energising. After power-up, set the input ranges, alarms and control parameters from the engineering displays, then run a manual-to-automatic changeover test with the process in a safe state.
Maintenance, calibration and service
Check input accuracy with a calibrator, test alarm contacts at a planned interval and keep a record of alarm settings.
Controllers of this class use non-volatile memory and need no battery replacement, so routine care is mostly inspection of terminals, cleaning of the front panel and periodic verification of input and output accuracy against a calibrator. Record the tuning parameters and any user program, and keep a spare configuration file so that a replacement can be commissioned quickly.
Related products and ordering notes for YS1310
- YS1500 and YS1700 controllers, and the YSS1000 setting software.
When you request YS1310, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. We can also check related codes so that a single RFQ covers the instrument and the parts that go with it.
Frequently asked questions about YS1310
- What is YS1310? YS1310 is a two-input indicator with high, low, high-high and low-low alarms and six alarm contacts.
- Can YS1310 control a loop? No. It is an indicator with alarms. For control, the YS1500 or YS1700 controllers are used.
- What power supply does YS1310 use? It can be driven by either 100 V AC or 24 V DC, and a 220 to 240 V option must be specified when ordering.
- Is YS1310 available as a replacement type? Yes. The manufacturer lists compatible types for YS80 internal units, EBS and I series, EK and HOMAC.
- How do I order YS1310? Send Seven Star LLC the model and suffix code, quantity and delivery location and we will quote.
Documents and quotation
The manufacturer General Specifications for the family of YS1310 is available and we can send it with your quotation. To request pricing and lead time, send an RFQ to Seven Star LLC with the part number YS1310, the quantity, the full model and suffix code or the nameplate details of the unit being replaced, the delivery location and any certificate requirements. We will confirm availability and reply in writing with a quotation for YS1310.
Datasheets & Documents
- Datasheet Yokogawa YS1310 Indicator with Alarms Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa YS1310 Indicator with Alarms
Answers from our engineering team on installation, compatibility and integration.
01What is YS1310?
YS1310 is a two-input indicator with high, low, high-high and low-low alarms and six alarm contacts.
02Can YS1310 control a loop?
No. It is an indicator with alarms. For control, the YS1500 or YS1700 controllers are used.
03What power supply does YS1310 use?
It can be driven by either 100 V AC or 24 V DC, and a 220 to 240 V option must be specified when ordering.
04Is YS1310 available as a replacement type?
Yes. The manufacturer lists compatible types for YS80 internal units, EBS and I series, EK and HOMAC.
05How do I order YS1310?
Send Seven Star LLC the model and suffix code, quantity and delivery location and we will quote.


















Reviews
There are no reviews yet.