Endress+Hauser CCS50E Memosens Chlorine Dioxide Sensor

Description

Endress+Hauser CCS50E Memosens chlorine dioxide sensor

The Endress+Hauser CCS50E is a digital amperometric sensor for dissolved chlorine dioxide (ClO2), built on Memosens technology. It is designed for skid builders and end users who disinfect drinking water, cooling water and process water with chlorine dioxide and who need to avoid both under-dosing and overdosing. The CCS50E is a membrane-covered, closed two-electrode cell, 25 mm in diameter and 161 mm long, that goes into the Flowfit CYA27 modular flow assembly. Seven Star LLC supplies the CCS50E in Oman and the GCC as an independent supplier in Muscat.

CCS50E technical specifications

Parameter Specification
Manufacturer / part number Endress+Hauser / Memosens CCS50E
Measuring principle Amperometric, membrane-covered 2-electrode cell
Measuring ranges 0 to 5; 0 to 20; 0 to 200 mg/l ClO2
Response time T90 below 15 s after polarisation
Process temperature 0 to 55 °C, non-freezing
Process pressure Maximum 2 bar absolute
Ambient temperature −20 to +60 °C
Dimensions Ø 25 mm, length 161 mm
Materials Shaft POM; membrane and cap PVDF
Interface Memosens 2.0 digital

How the CCS50E measures chlorine dioxide

Chlorine dioxide diffuses through the PVDF membrane and is reduced to chloride at the working electrode at about 120 mV, while silver is oxidised to silver chloride at the counter electrode. The resulting current is proportional to ClO2 concentration, and over a wide range it does not depend on pH. The response time is T90 below 15 s after polarisation. After first connection or a prolonged power interruption the sensor needs a polarisation period before the readings are valid.

CCS50E ranges and data

Three versions cover different ranges: trace 0 to 5 mg/l, standard 0 to 20 mg/l and high 0 to 200 mg/l ClO2. The process temperature is 0 to 55 °C, non-freezing, the maximum pressure is 2 bar absolute, and the ambient range is −20 to +60 °C. The sensor shaft is POM and the membrane and membrane cap are PVDF. Storage with electrolyte is limited to a maximum of two years, and the sensor can stay without electrolyte only up to 48 hours.

Memosens and system integration

With Memosens 2.0, the sensor can be precalibrated in the laboratory and swapped on site by plug and play. It is connected through the Memosens cable CYK10 to a Liquiline transmitter, and the Flowfit CYA27 assembly can include an inductive flow switch for dry-run protection and a sampling valve for a grab-sample check. The recorded sensor load data helps predict when to replace the membrane cap or electrolyte.

Selecting the CCS50E

Select the range from your dosing target: trace for beverage and reverse-osmosis permeate where chlorine dioxide must be absent, standard for drinking water, and high for process disinfection. Check that your sample flows continuously at the required rate across the sensor in the CYA27 and that the sample temperature and pressure are within the limits. Chlorine dioxide sensors are specific but should be checked for interference from other oxidisers in your water.

Commissioning and maintenance of the CCS50E

Fill the sensor with electrolyte, allow the polarisation to finish, and calibrate by comparing with a photometric DPD reference measurement on a sample taken at the sensor. Replace the membrane cap and electrolyte on a schedule set by water quality and by the load data. Keep the sensor wet, protect it from frost, and flush the flow assembly regularly to prevent biofilm.

Chlorine dioxide monitoring in Oman and the GCC

Chlorine dioxide is used in the Gulf for potable-water disinfection, cooling towers and district-cooling loops, food and beverage plants and reverse-osmosis systems. Warm water increases both microbiological risk and the volatility of ClO2, so a continuous measurement helps hold the dose within limits. Make the flow assembly easily accessible for operators and verify the sensor against grab samples regularly.

CCS50E versions compared

Version Range Typical use
Trace 0 to 5 mg/l Absence check, RO and beverage
Standard 0 to 20 mg/l Drinking and cooling water
High 0 to 200 mg/l Process disinfection

Information to send with a CCS50E RFQ

  • Application and target concentration
  • Range version (trace, standard, high)
  • Flow, temperature and pressure of the sample
  • Assembly (CYA27) and cable length
  • Transmitter model
  • Quantity and delivery location

Spares, consumables and calibration records for the CCS50E

Plan consumables for the CCS50E: membrane caps, electrolyte and sealing rings are replaced on a schedule, and a spare calibrated sensor lets you swap rather than wait for polarisation. Keep a log of calibration dates, DPD reference values, slope and sensor load, because disinfection data may be audited. Sensors must not be left dry or with electrolyte past the stated storage limits, so mark the date on stored spares.

If the reading is noisy or low, check the sample flow and the flow switch first, then the membrane for damage or deposits, and then the electrolyte level. A membrane scratched during cleaning must be replaced rather than cleaned again.

Water-quality notes for the CCS50E

Chlorine dioxide is consumed by organic load and light, so measure close to the dosing point and at a representative return point, and compare the two readings to follow decay along the system.

Site conditions in Oman for the CCS50E

Field instruments in Oman are exposed to strong sun, high ambient temperature, wind-blown dust and, on coastal plants, salt in the air. When you specify the CCS50E, check the ambient and process temperature limits, the enclosure rating and the wetted and housing materials against the actual installation point, and consider sunshades for transmitters mounted in direct sunlight. Cable entries should be sealed with suitable glands so that dust and moisture cannot enter the housing.

Calibration and verification planning matters as much as selection. Record the range, configuration and tag data of each CCS50E at commissioning, define a check interval that suits the criticality of the loop, and keep the certificates with the plant documentation so that audits and shutdown work can proceed without delay.

Documents and quotation

A copy of the manufacturer technical information for the CCS50E is attached on this page so you can check ranges, connections and ordering codes against your specification.

Send the full order code or the process data (fluid, temperature, pressure, line size or tank data, output and approvals) and Seven Star LLC will prepare a quotation and confirm lead time. We are an independent supplier in Muscat and do not represent the manufacturer.

Datasheets & Documents
  • PDF Datasheet Endress+Hauser CCS50E Technical Information Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser CCS50E Memosens Chlorine Dioxide

Answers from our engineering team on installation, compatibility and integration.

01What does the CCS50E measure?
Dissolved chlorine dioxide in water with a membrane-covered amperometric cell.
02Which measuring ranges exist?
Three: trace 0 to 5 mg/l, standard 0 to 20 mg/l and high 0 to 200 mg/l.
03How fast is the response?
T90 below 15 seconds once the sensor is polarised.
04Where is it installed?
In the Flowfit CYA27 modular flow assembly, connected through a Memosens cable to a Liquiline transmitter.
05What are the process limits?
0 to 55 °C without freezing, and a maximum of 2 bar absolute.