Moore Industries THZ/PRG/4-20MA/12-42DC [DIN] Rail Transmitter

Description

Moore Industries THZ/PRG/4-20MA/12-42DC [DIN] in the compact DIN-rail housing

Moore Industries THZ/PRG/4-20MA/12-42DC [DIN] puts the Smart HART temperature measurement of the THZ into a slim aluminum housing that snaps onto both 32 mm G-type and 35 mm Top Hat rails. It has no front display, so it belongs in marshalling cabinets, junction boxes and rack rooms where a technician connects with a HART communicator rather than reading a local screen.

The DIN code is the densest way to buy THZ capability: it carries the same universal input, the same sensor diagnostics and the same 20-bit input converter as the field enclosures, only without the glass and the display. Spares planners like this variant because one stocked unit can be configured for dozens of different sensor ranges.

What THZ/PRG/4-20MA/12-42DC [DIN] offers

  • Universal input covering fourteen RTD curves, nine thermocouple types, resistance and millivolts.
  • Output of 4-20 mA that is linear in temperature, with a digital HART channel for diagnostics and re-ranging from the control room.
  • Sensor trim at two points, custom linearization tables and damping of up to 30 seconds.
  • Long-term drift of only 0.019% of span over five years for thermocouple or millivolt service.
  • Screw terminals for the sensor and for the loop, with a rail mount that allows a replacement unit to be fitted quickly.

Immunity to radio-frequency interference is quoted as 30 V/m by the SAMA test method and 10 V/m by the IEC 1000-4-3 method, both with an error of 0.5% of span or less.

THZ/PRG/4-20MA/12-42DC [DIN] specifications

Values from the THZ and TDZ datasheet for the DIN-style module are summarised below.

Parameter Value for THZ/PRG/4-20MA/12-42DC [DIN]
Model code THZ/PRG/4-20MA/12-42DC [DIN]
Housing DIN: aluminum DIN-style housing for 32 mm G-type (EN 50035) and 35 mm Top Hat (EN 50022) rail
Input Programmable (PRG): RTD 2-, 3-, 4-wire Pt, Cu, Ni; thermocouple J, K, E, T, R, S, B, N, C; 0 to 4000 ohm; -50 to 1000 mV; potentiometer
Output 4-20 mA scalable with HART superimposed; HART address 0 to 15
Supply 12-42 V DC at the loop terminals
Isolation 500 Vrms input to output continuous; passes a 500 Vac dielectric test for one minute
Step response 600 ms maximum from input step to 90% of output
Rise time 100 ms maximum, 10% to 90%
Analog output accuracy Plus or minus 0.015% of span
Digital accuracy Plus or minus 0.1 C with Pt RTDs; plus or minus 0.05 C with Pt1000 under matched conditions
Long-term stability (T/C, mV input to HART) 0.0084% of span in 1 year, 0.0145% in 3 years, 0.019% in 5 years
RFI/EMI immunity 30 V/m per SAMA 33.1 abc, 10 V/m at 80-1000 MHz per IEC 1000-4-3, 0.5% of span or less error
Ambient -40 to +85 C, 0 to 95% RH non-condensing
Weight 221 g (7.9 oz)
Display None; no integral display in the DIN housing
Reference junction error Plus or minus 0.45 C for thermocouple inputs

How THZ/PRG/4-20MA/12-42DC [DIN] differs from other THZ housings

Compared with the HPP puck, which weighs only 101 g and is isolated to 1000 Vrms, the DIN version weighs 221 g and is isolated to 500 Vrms. Compared with the DH enclosure it is smaller and lighter than the 1.75 kg case but has no display. Its step response of 600 ms maximum matches the other THZ modules and is faster than the 700 ms of the DH case.

Because the DIN style is not available with the -ISF option, hazardous-area use means mounting it in a safe area and connecting the sensor through a barrier or isolator, rather than putting the transmitter itself into the classified zone.

Applications for THZ/PRG/4-20MA/12-42DC [DIN] in GCC plants

Typical uses include thermocouple inputs from furnace skin points to a rail-mounted signal conditioner in a power plant, RTD inputs from bearing sensors in a pump house, and multi-point temperature monitoring in a utility building. In desalination plants the DIN transmitter lives in the electrical room, close to the DCS I/O.

Where rack space is limited, the slim DIN-style profile lets many channels sit side by side. Since each unit is HART capable, an asset management package can poll them from the cabinet without climbing to the sensor location.

Selection and compatibility of THZ/PRG/4-20MA/12-42DC [DIN]

Choose this code when the sensor wiring is short enough to keep lead resistance below 4000 ohms in total, and keep three-wire cables to less than 35 ohms per leg for the stated accuracy. Confirm that the DCS input card or loop power supply delivers 12 V at the terminals; the supply voltage minus 12 V divided by 0.024 A sets the permitted loop resistance.

For hazardous-area sensors consider the later THZ3 or STZ DIN versions with the -AIS option, which build the intrinsically safe barrier into the module; this older code does not.

Mounting and setting up THZ/PRG/4-20MA/12-42DC [DIN]

Clip the housing onto the rail, tighten the terminal screws on the sensor leads (terminals 1 to 4) and the loop leads (PS terminals), then power the loop. Connect a HART communicator or a HART modem on any point of the 4-20 mA wires, pick the sensor type, set the range and the failure direction, and run a loop test to confirm the receiving system reads the fixed current.

Because the memory is non-volatile, the transmitter resumes operation with its configuration after any interruption of power and reaches rated performance 8 seconds after power-up.

Care and troubleshooting of THZ/PRG/4-20MA/12-42DC [DIN]

There are no user adjustments inside the housing. Periodically check the terminal torque, keep the ventilation area free, and compare the output against a calibrator at the sensor end. A sensor fault produces an upscale 23.6 mA or downscale 3.6 mA signal according to configuration, together with a HART error message identifying the problem.

Document the programmed trim values; if a replacement unit is fitted, reload the saved file with the configuration software to restore exactly the same behaviour.

Supply notes for THZ/PRG/4-20MA/12-42DC [DIN]

Please include the full code THZ/PRG/4-20MA/12-42DC [DIN] in any enquiry and mention the sensor type and range if you want it factory configured.

Seven Star LLC is an independent supplier serving Oman and the wider GCC and is not affiliated with the manufacturer; all names and part numbers are used only to identify the product being requested.

Documents and quotation

A datasheet for Moore Industries THZ/PRG/4-20MA/12-42DC [DIN] is available for review with every quotation. Send the RFQ with the part number, quantity and shipment location, and we will reply with the commercial details.

Other Models in the THZ TDZ Range

Seven Star LLC supplies models from the THZ TDZ range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Moore Industries TDZ/PRG/4-20MA/12-42DC [BH2NGE] TransmitterTemperature TransmittersView details
Moore Industries THZ/PRG/4-20MA/12-42DC [HPP] Head TransmitterTemperature TransmittersView details
Moore Industries THZ/PRG/4-20MA/12-42DC [WL2NG] WirelessHART CaseTemperature TransmittersView details
Moore Industries THZ/PRG/4-20MA/12-30DC/-ISF [DH2NGP] TransmitterTemperature TransmittersView details
Moore Industries THZ/PRG/4-20MA/12-42DC [DIN] Rail TransmitterTemperature TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Moore Industries THZ/PRG/4-20MA/12-42DC [DIN] Rail Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.

Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.

Moore Industries company profile

Founded 1968, North Hills, California, USA, by Leonard W. Moore
Headquarters North Hills, California, since 1974
Ownership Privately owned (Moore Industries-International, Inc.)
First product SCT signal converter
Product families Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA)

Milestones

  • 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
  • 1974: The company moves into its North Hills headquarters.
  • 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.

Moore Industries product families on this page

The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:

  • Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
  • Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
  • Signal isolators, repeaters and converters: the SIX
  • PID controllers and backup stations: the 535 in 1/4 DIN format

Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.

Where Moore Industries instruments are used

These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.

Moore Industries products we list

Family Examples
Controllers & Data Acquisition Moore 535-21120BD000 | Industrial PID Ba…, SPA2 Programmable Limit Alarm Trip, Moore-SPA2HL Associated IS Programmable…
Isolator & Barrier HIM Smart HART Loop Interface and Monitor, SIX Signal Isolator, SLA SIL 2/3 Safety Logic Solver and Alarm
Temperature Instrumentation STZ Functional Safety Dual Input Smart H…, TRX Temperature Transmitter
Industrial Communications HES HART to Ethernet Gateway
Valve Positioners IPT2 Current-to-Pressure I/P Transmitter

Ordering Moore Industries instruments: what we need

Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.

Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.

FAQ

Questions about the Moore Industries THZ/PRG/4-20MA/12-42DC [DIN] Rail

Answers from our engineering team on installation, compatibility and integration.

01Does this THZ have a display?
No. The DIN version is a rail-mount module without a screen; displays are found on the DH enclosure and on TDZ models.
02Which rails does the DIN housing fit?
It mounts on 32 mm G-type (EN 50035) and 35 mm Top Hat (EN 50022) rails.
03How much does the DIN unit weigh?
The datasheet gives 221 g (7.9 oz), compared with 101 g for the HPP module.
04What is the isolation level?
500 Vrms input to output continuous, with a one-minute 500 Vac dielectric strength test.
05Can it be installed in a hazardous area?
The DIN housing is not offered with the -ISF option, so it is normally installed in a safe area with sensors connected through suitable protection.