- Automation & ControlView all 2,895 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: JUMO
JUMO 902150/10-378-1003 Push-in Pt100 Probe, 6 mm, 2.5 m Cable
Description
JUMO 902150/10-378-1003-1-6-100-11-2500/000 is the straight, cable-outlet member of the 902150 push-in resistance thermometer range: one Pt100 in 2-wire circuit, a 6 mm stainless steel protection tube of 100 mm insertion length, and 2.5 m of silicone-insulated cable finished with ferrules. Because the datasheet lists climatic chambers, laboratory technology, solar units and air-conditioning systems among the target areas, it is a typical choice for compact assemblies where there is no room for a terminal head. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Overview of 902150/10-378-1003-1-6-100-11-2500/000
A push-in probe has no process thread of its own: it slides into a pocket, a clamp fitting or a drilled block and is held by the user’s own fixture. That makes the 902150 attractive for retrofit and test benches. The manufacturer states that the unit measures temperature in liquids and gases and is suitable for dry and humid rooms. The cable is strain-relieved at the tube and the protection tube is stainless steel. Optional bend protection is listed for the series, but with extra code 000 this version has none.
Order-code breakdown for 902150/10-378-1003-1-6-100-11-2500/000
| Segment | Meaning |
|---|---|
| 902150/10 | Push-in probe with connection line and straight stainless steel protection tube |
| 378 | Operating temperature minus 50 to plus 180 degrees Celsius, silicone line |
| 1003 | 1x Pt100, DIN EN IEC 60751, 2-wire circuit |
| 1 | Tolerance class B |
| 6 | Protection tube diameter 6 mm |
| 100 | Insertion length EL 100 mm |
| 11 | Connection line end: ferrules |
| 2500 | Connection line length AL 2500 mm |
| 000 | No extra code |
Performance figures from the datasheet
For the 6 mm tube the datasheet quotes a response time in water at 0.4 m/s of about 4 seconds to reach 50 percent and about 10 seconds for 90 percent. In moving air at 3 m/s the same tube needs about 32 seconds and about 98 seconds. These numbers explain why the part works well for fluid lines and chamber control but should not be trusted for fast air transients. The silicone line tolerates minus 50 to plus 180 degrees Celsius, compared with minus 5 to plus 80 for PVC, minus 50 to plus 260 for PTFE or metal braiding, and plus 400 for glass fibre.
How 902150/10-378-1003-1-6-100-11-2500/000 differs from other 902150 variants
This code uses the straight type 10, whereas types 40 and 41 bring the cable out at a right angle or bend the protection tube itself, with 50 and 70 mm leg dimensions shown on the drawing. Protection tubes from 3 mm to 6 mm are offered; this version carries the largest, so it responds more slowly than a 3 mm tube but is stiffer. Stock siblings change the sensor, for example 902150/10-378-1001 with 3-wire circuit, 902150/10-378-2003 with two Pt100 elements, or 902150/10-386 with PTFE cable, while this part stays with the simplest single 2-wire Pt100 and class B.
Where it is used in the Gulf
Typical Omani and GCC cases include thermal test chambers in quality laboratories, water-cooled enclosures, heat pumps and solar thermal circuits, chilled water bypass lines on HVAC plants, and OEM packaged equipment such as ice machines. The straight 6 mm form fits standard pockets and compression fittings found on such skids.
Selection and compatibility
Decide first whether 2-wire accuracy is adequate: lead resistance adds a constant error, so a 2.5 m cable matters on short spans. If a transmitter or controller can compensate for a fixed offset, 2-wire is acceptable. Where more accuracy is needed, 3-wire or 4-wire inserts are separate codes in the same datasheet. SIL and PL qualified versions exist through other extra codes, but they must be requested explicitly and are not included in 902150/10-378-1003-1-6-100-11-2500/000.
Installation and commissioning
Insert the probe to the full 100 mm and clamp or seal it in the fitting; do not pull on the cable. Keep the silicone line away from hot surfaces beyond its limit and avoid sharp bends right at the outlet. Strip nothing: the ferrules are already crimped, so connect them directly to the terminals of the instrument. Compare the reading with a reference thermometer in a stirred bath before accepting the loop.
Maintenance of 902150/10-378-1003-1-6-100-11-2500/000
Inspect the cable jacket and the tube at planned shutdowns. Slow response is usually caused by poor contact in the pocket or by deposits, not by the element. Because the sensor is fixed, replace the complete assembly, and keep the part number 30056173 in the spares list.
Practical wiring notes for 902150/10-378-1003-1-6-100-11-2500/000
With a 2-wire Pt100 the two conductors carry both the measuring current and the lead resistance. Many controllers allow a lead resistance compensation value or a manual offset; set it after measuring the loop at a known temperature. Keep the cable away from motor leads and variable-speed drives, since the Pt100 signal is only a few millivolts, and ground any shield only at the instrument end. At 2.5 m of cable length, the added resistance is small, but it is not zero, which is why the datasheet offers 3-wire and 4-wire circuits for precision work. If the line must be shortened on site, cut it and re-terminate the ferrules rather than coiling the excess near the tube, because a tight coil trapped against a warm tube ages silicone insulation faster.
When the part is used in a laboratory or a climatic chamber, mount it so that the tip sits in the air stream or the liquid and not against the chamber wall, otherwise 902150/10-378-1003-1-6-100-11-2500/000 will report a wall temperature that lags the real medium.
Documents and quotation
The JUMO 902150 datasheet is attached for dimensions and options. For a quotation on 902150/10-378-1003-1-6-100-11-2500/000, send the order code, the quantity and the delivery point in Oman or the GCC with your RFQ.
Datasheets & Documents
- Datasheet JUMO 902150/10-378-1003 Push-in Pt100 Probe, 6 mm, 2.5 m Cable Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
JUMO is the German maker of temperature sensors, process controllers, pressure transmitters and liquid analysis instruments. Moritz Kurt Juchheim founded it in Fulda in 1948 as M. K. Juchheim KG, making glass thermometers with six employees. The name JUMO comes from the founder's name. It is still a family company headquartered in Fulda, and the parent company has been called JUMO GmbH & Co. KG since 2003.
Seven Star LLC is an independent supplier in Muscat. We list JUMO RTD and thermocouple probes, thermowells, transmitters, controllers, recorders and water analysis instruments, and supply them to process plants, OEMs, HVAC contractors and water utilities in Oman and the GCC by type number.
JUMO company profile
| Established | 1948, Fulda, Germany, by Moritz Kurt Juchheim |
|---|---|
| First products | Glass and contact thermometers; platinum glass sensors from 1966 |
| Ownership | Family-owned; renamed JUMO GmbH & Co. KG in 2003 |
| Product families | RTD and thermocouple probes, thermowells, temperature and pressure transmitters, controllers and thermostats, safety temperature limiters, paperless recorders, liquid analysis and flow and level instruments |
Milestones
- 1948: Moritz Kurt Juchheim founds M. K. Juchheim KG in Fulda, making glass thermometers with six employees.
- 1966: Platinum glass temperature sensors are added.
- 2003: The parent company is renamed JUMO GmbH & Co. KG.
JUMO products we list
| Family | Models | Typical use |
|---|---|---|
| RTD and thermocouple probes | 902020, 902030, 902050, 902120, 902006 2xPt100, PROCESStemp, mineral-insulated RTD, 901020 thermocouple, 901210, 902810 hygienic, 902550 surface, 902520 HVAC, MarineTemp | Temperature measurement in pipes, vessels, machines, HVAC and food plants |
| Thermowells and inserts | 909710 thermowells, 909740 measuring inserts | Protecting sensors and replacing them without opening the process |
| Temperature transmitters | dTRANS T01, T03, T04, T05, T06 SIL, T07 HART, T09, T1000 IO-Link, DELOS T switch | Converting sensor signals to 4-20 mA, HART or IO-Link |
| Pressure and level | dTRANS p20, p30, p31 hygienic, p33 Ex, p02 DELTA, MIDAS S05, MIDAS DP10, DELOS S02, MAERA S25, NESOS R20 | Pressure in process, hydraulic and OEM systems; tank and well level |
| Controllers, limiters and recorders | DICON touch, IMAGO 500, dTRON 316, iTRON, cTRON, diraTRON 104, eTRON T, safetyM STB/STW, safetyM TB/TW, LOGOSCREEN 601, mTRON T | Furnace, oven and process control, over-temperature protection and recording |
| Liquid analysis and flow | AQUIS touch S, AQUIS touch P, AQUIS 500 pH, AQUIS 500 CR, dTRANS pH 02, pH electrode, digiLine DO, ecoLine NTU, flowTRANS MAG H20, flowTRANS US W01 | pH, conductivity, oxygen and turbidity in water treatment; liquid flow |
Choosing a temperature sensor starts with the range and accuracy. A Pt100 RTD is accurate and stable from about -200 to 600 °C and is the usual choice in process plants. A thermocouple (type K or J, for example) covers much higher temperatures and responds faster but is less accurate. The wiring also matters: a 3-wire or 4-wire Pt100 connection cancels the resistance of the cable, while a 2-wire connection adds an error that grows with cable length. That is why a head-mounted transmitter is often fitted close to the sensor.
Where JUMO products are used
In Oman and the GCC, JUMO sensors and controllers are used in oil and gas and chemical plants, food and beverage production, plastics and metal heat treatment, HVAC and district cooling, water and wastewater treatment, swimming pools and marine applications.
Ordering JUMO products: what we need
Send the JUMO type number and the full order code from the label (for example 902020/10-...). For probes, add the sensor type (Pt100, Pt1000, type K or J), the number of wires, the insertion length and diameter, and the process connection. For controllers, add the input, outputs and supply voltage.
Facts checked against JUMO's company history, October 2026.
Browse JUMO products by category: Temperature Instrumentation, Pressure Instrumentation, Liquid Analysis Sensors, Controllers & Data Acquisition, Level Transmitter.
FAQ
Questions about the JUMO 902150/10-378-1003 Push-in Pt100 Probe, 6 mm,
Answers from our engineering team on installation, compatibility and integration.
01How fast does 902150/10-378-1003-1-6-100-11-2500/000 respond?
The datasheet gives t0.5 of about 4 s and t0.9 of about 10 s in water at 0.4 m/s, and about 32 s and 98 s in air at 3 m/s, for the 6 mm tube.
02What cable is fitted to 902150/10-378-1003-1-6-100-11-2500/000?
Operating code 378 means a silicone connecting line rated minus 50 to plus 180 degrees Celsius, 2500 mm long and strain relieved, ending in ferrules per code 11.
03Is 902150/10-378-1003-1-6-100-11-2500/000 a 3-wire probe?
No. Code 1003 is a single Pt100 to DIN EN IEC 60751 in 2-wire circuit, while 3-wire and 4-wire versions use codes 1001 and 1011.
04Does 902150/10-378-1003-1-6-100-11-2500/000 have bend protection?
Bend protection and shielding are optional extra codes in the series, but this order code ends in 000, so no extra option is fitted.
05What is the insertion length of 902150/10-378-1003-1-6-100-11-2500/000?
The code segment 100 sets an insertion length EL of 100 mm on a 6 mm diameter stainless steel protection tube, with the cable leaving straight from the rear.


















Reviews
There are no reviews yet.