- Automation & ControlView all 2,895 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Endress+Hauser (E & H)
Endress+Hauser CPS72E Memosens ORP Sensor, Poison Resistant
Description
Endress+Hauser CPS72E Memosens ORP sensor for fast-changing redox
Endress+Hauser CPS72E measures oxidation-reduction potential rather than pH. A platinum measuring element reports the redox state of the liquid against an Ag/AgCl reference, over a span of minus 1500 to 1500 mV. The datasheet frames it for process technology and monitoring where ORP values change quickly or where electrode poisons such as hydrogen sulphide are present.
The reference system is a 3 M gel KCl bridge free of AgCl and equipped with an ion trap, so the silver lead stays protected longer. As with other 2.0 sensors, a Memosens head digitises the signal, stores calibration and sensor load, and passes data inductively. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
CPS72E technical specifications
| Parameter | Value |
|---|---|
| Measured variable | ORP, temperature |
| ORP range | minus 1500 to 1500 mV |
| Process temperature | 0 to 140 C (32 to 284 F) |
| Process pressure | 0.8 to 14 bar absolute (11.6 to 203 psi) |
| Minimum conductivity | 10 microsiemens per cm, atmospheric pressure, no flow |
| Reference | Ag/AgCl, gel KCl 3 M, AgCl-free, with ion trap |
| Measuring element | Platinum |
| Junction | Ceramic, zirconium dioxide |
| Temperature sensor | NTC 30K |
| Installed length | 120, 225, 360, 425 mm |
| Weight | 40, 60, 90, 100 g |
| Shaft diameter | 11.9 mm (0.47 in) |
| Materials | Glass shaft, FKM O-ring, PPS-GF process coupling |
| Plug-in head | Memosens, 16 bar relative |
| Ingress protection | IP 68, 10 m, 25 C, 45 days, 1 M KCl |
| Storage | 0 to 50 C |
| Ex marking | ATEX II 1G Ex ia IIC T3/T4/T6 Ga |
How CPS72E differs from other Memosens sensors
Where CPS91E and CPS41E report pH through glass, CPS72E carries a platinum element and a range stated in millivolts. Its 140 C ceiling is the highest in this group, above 135 C for CPS41E and 110 C for CPS91E, while its 14 bar pressure rating equals CPS91E. Compared with CPS92D, an older Orbipore ORP electrode with open aperture, CPS72E uses a ceramic junction with ion trap instead; its minimum conductivity is 10 microsiemens per cm whereas the open-aperture CPS92D is made for contaminated media.
Applications for CPS72E in Oman and the GCC
ORP is the workhorse control signal for oxidant and reductant dosing. Typical uses are cooling-water and effluent treatment where chlorine or bisulphite are dosed against a millivolt setpoint, sulphur-bearing process streams in gas processing, and neutralisation lines. Poison resistance matters where sour streams exist in refineries and gas plants.
Selection and compatibility notes
Pair with Liquiline CM42 or CM44x. Assemblies mentioned for the Memosens family include Dipfit CPA111 immersion, Flowfit CPA250 flow, Cleanfit CPA871 retractable and Unifit CPA842 fixed. Select the installed length for assembly depth. Because ORP has no standard calibration slope, verify the reading with a redox buffer in the laboratory.
Installing and commissioning CPS72E
Keep at least 15 degrees from horizontal because a shallower angle lets the electrolyte separate from the junction at elevated temperature. Tighten at 3 Nm in Endress+Hauser assemblies, check thread and O-ring first and remove the moistening cap only for installation.
Maintenance of CPS72E
Use the stored load data to schedule replacement. Cleaning in place is allowed. Store at 0 to 50 C with the cap fitted, and handle pressurised sensors with eye protection.
How redox measurement with CPS72E works
The platinum element does not respond to H+ ions as a pH glass does; it acts as an inert electron exchange surface. The potential that appears against the Ag/AgCl reference reflects the ratio of oxidised to reduced species in the liquid, for example hypochlorite against chloride, or sulphite against sulphate. That is why ORP responds quickly to dosing changes, and why the datasheet singles out rapidly changing ORP values as a target application.
The reference electrolyte is a gel of 3 M KCl that is free of silver chloride, acrylamide-free, and contains an ion trap. Silver ions in the bridge would otherwise precipitate with sulphide and clog the junction; removing them and trapping migrating ions is what lets CPS72E live in sour or reducing streams. The junction is zirconium dioxide ceramic, the shaft is glass chosen to suit the process, and the sealing is FKM.
Quick answers about CPS72E
Where does the reading come from? A platinum cap at the tip of the shaft. What does the head store? Calibration data, sensor load and operating hours, which the transmitter and Memobase Plus CYZ71D can display. What is the lowest conductivity? 10 microsiemens per cm, with minimized flow and constant pressure and temperature. What about cleaning? CIP and SIP are listed, with autoclaving allowed. What is the cable length limit? That belongs to the CYK10 or CYK20 cable and transmitter, so check their documents when planning a long run.
Ordering notes for CPS72E
Provide the complete order code, including length and Ex approval, with every RFQ. The order code of CPS72E selects the installed length (120, 225, 360 or 425 mm) and the approval, and the delivery includes the operating instructions plus safety instructions for hazardous areas where an Ex version is ordered. Related ORP and pH lines such as CPS92D, CPS91E and CPS41E are listed separately; pairing CPS72E with a pH sensor in the same Flowfit CPA250 flow cell is a common arrangement in dosing control, because both read through the same Memosens cable family and the same Liquiline transmitter. If you are replacing an older ORP electrode, send the existing nameplate code and we will check the installed length and head type against the CPS72E range.
Documents and quotation
The Technical Information datasheet for CPS72E is attached to this page as a PDF. To request a quotation, send your RFQ with the exact CPS72E order code and the quantity you need, and we will reply with availability and lead time.
Other Models in the Memosens Orp Range
Seven Star LLC supplies models from the Memosens Orp range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser CPS62E Memosens ORP Sensor (Sterilizable) | Liquid Analysis Sensors | View details |
| Endress+Hauser CPF82E Memosens Compact ORP Sensor | Liquid Analysis Sensors | View details |
| Endress+Hauser CPS72E Memosens ORP Sensor, Poison Resistant | Liquid Analysis Sensors | You are viewing this model |
| Endress+Hauser CPS92D Orbipore ORP Electrode, Memosens | Liquid Analysis Sensors | View details |
Datasheets & Documents
- Datasheet Endress+Hauser CPS72E Memosens ORP Sensor, Poison Resistant Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser CPS72E Memosens ORP Sensor, Poison
Answers from our engineering team on installation, compatibility and integration.
01What range does Endress+Hauser CPS72E measure?
Redox potential from minus 1500 to plus 1500 mV, plus temperature through an integrated NTC 30K element.
02What makes CPS72E poison resistant?
The reference has an improved ion trap and a bridging electrolyte free of silver ions and acrylamide, which protects the Ag/AgCl system against poisons such as hydrogen sulphide.
03What is the process limit of CPS72E?
0 to 140 C and 0.8 to 14 bar absolute, with a minimum conductivity of 10 microsiemens per cm at atmospheric pressure without flow.
04Can CPS72E be steam sterilized?
The datasheet lists it as suitable for CIP and SIP cleaning and autoclavable.
05Which transmitters work with CPS72E?
Memosens transmitters such as Liquiline CM42 or CM44x via cable CYK10 or CYK20; analog ORP inputs cannot read the digital head.


















Reviews
There are no reviews yet.