Endress+Hauser CLS21E Memosens conductivity sensor for medium and high conductivity

The Endress+Hauser CLS21E is a graphite-electrode conductivity sensor with Memosens digital communication, nominal cell constant k = 1.0 per cm and a measuring range of 10 microsiemens per cm to 20 mS per cm. It is the practical choice for mid-range ionic media such as wastewater, drinking water and alkali-water separation, and the datasheet adds ballast water cleaning and ship’s-wake water cleaning to its application list.

Where the CLS15E serves ultrapure water, the CLS21E serves everything above about 10 microsiemens per cm, up to the point where a salinity probe takes over.

Features of CLS21E

  • Graphite electrodes, PES-GF20 shaft, titanium thermowell socket
  • Range 10 microsiemens per cm to 20 mS per cm
  • Temperature measuring range minus 20 to 135 °C; pressure up to 17 bar absolute
  • Individual cell constant stated in an inspection certificate
  • Pt1000 Class A temperature compensation
  • Fast response of 2 seconds or less at t95

CLS21E specifications

Parameter Value
Cell constant k = 1.0 per cm, nominal
Conductivity range 10 microsiemens per cm to 20 mS per cm
Temperature range Minus 20 to 135 °C at 3.5 bar absolute
Pressure 17 bar abs. at 20 °C
Electrodes Graphite
Shaft Polyethersulfone PES-GF20
Temperature socket Titanium 3.7035
Connections G1 thread or NPT 1 inch
Weight About 0.3 kg
Ambient / storage Minus 20 to 60 °C / minus 25 to 80 °C
Protection IP 68 / NEMA type 6P, 1 m water column, 25 °C, 24 h

How CLS21E differs from CLS15E, CLS16E and CLS82E

Numbers make the difference clear. The CLS21E has k = 1.0 and starts at 10 microsiemens per cm; the CLS15E has k = 0.01 or 0.1 and stops at 200 microsiemens per cm; the CLS16E has k = 0.1 and reaches 500 microsiemens per cm; the CLS82E has k = 0.57, spans 1 microsiemens to 500 mS per cm and uses a platinum and ceramic element with 316L fittings. The CLS21E is the lowest-cost route to a robust 10 microsiemens to 20 mS band.

Applications in Oman

Wastewater inlet and outlet monitoring, drinking-water treatment, brine and caustic regeneration lines, and marine water cleaning are the likely homes for the CLS21E in Oman and the Gulf.

Installation

Mount the CLS21E in a flow or immersion assembly, as the datasheet states. Keep the electrodes fully wetted, avoid air pockets, and leave enough clearance to the vessel wall that field effects do not alter the cell constant.

Maintenance

Graphite surfaces can coat with oils, so clean with a mild detergent and verify against a conductivity standard. Because the sensor stores its history, a replacement can be installed and recognized by the transmitter immediately.

Compatibility

Use cable CYK10 and a Liquiline CM442, CM444, CM448, CM42 or CM14 transmitter with the CLS21E.

Graphite cell construction and why it matters

The CLS21E uses graphite electrodes mounted in a polyethersulfone (PES-GF20) shaft, with a titanium (3.7035) thermal-conductivity socket that carries the Pt1000 temperature probe. Graphite is chemically tolerant in alkaline and moderately aggressive solutions, which is why the datasheet mentions alkali-water phase separation and wastewater among its uses. It is a robust cell with a nominal constant of 1.0 per cm, each sensor being factory-measured in a solution of about 5 mS per cm against a reference system, with a manufacturer inspection certificate giving the individual value.

Process connections are a G1 thread or a 1 inch NPT thread, and the weight is about 0.3 kg depending on the version.

Temperature and pressure window

The sensor reads from minus 20 to 135 degrees Celsius, but that top temperature applies at 3.5 bar absolute. At 20 degrees Celsius the pressure rating rises to 17 bar absolute, and the datasheet shows the steps in between at 13 bar, 9 bar, 5 bar and 3.5 bar as the temperature climbs. Plan any hot-water or steam-condensate application against that chart, since the pressure allowance drops quickly above 90 degrees Celsius.

Conductivity measurement in practice with the CLS21E

A two-electrode cell measures the electrical resistance of the liquid between its electrodes, and conductivity is the reciprocal of that resistance multiplied by the cell constant. Because ionic solutions conduct better when they are hotter, the transmitter uses the Pt1000 Class A temperature reading to compensate to a reference temperature, so the numbers on the display stay comparable from morning to afternoon. The CLS21E gives a response of 2 seconds or less at t95, so the loop reacts quickly to a slug of brine or a cleaning chemical.

The Memosens link digitizes the signal in the head, so cable length and moisture in the plug do not distort the reading as they can with analog conductivity cells. Calibration data, the cell constant and the operating history are stored in the sensor.

Choosing the right cell for your range

If your normal reading is below 10 microsiemens per cm, the CLS21E is the wrong cell and you should look at a lower-constant sensor. If your normal reading is above 20 mS per cm, a sensor with a wider top end such as the CLS82E is better. For anything between, including municipal wastewater, treated effluent, hardness-laden raw water and typical alkali-water separation, the CLS21E with k = 1.0 per cm sits comfortably in the middle of its range, which keeps accuracy good and drift small.

Order information to give with an RFQ: the thread (G1 or NPT 1 inch), the transmitter model, and whether the sensor will be used in a flow assembly or an immersion assembly. The datasheet notes that the sensor may be installed via either type of assembly.

Documents and quotation

The datasheet for the CLS21E is attached. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with CLS21E, connection thread (G1 or NPT 1 inch) and quantity.

Other Models in the Memosens Conductivity Range

Seven Star LLC supplies models from the Memosens Conductivity range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser CLS82E Memosens Wide-Range Conductivity SensorLiquid Analysis SensorsView details
Endress+Hauser CLS15E Memosens Conductivity Sensor (Pure Water)Liquid Analysis SensorsView details
Endress+Hauser CLS21E Memosens Conductivity Sensor, GraphiteLiquid Analysis SensorsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Endress+Hauser CLS21E Memosens Conductivity Sensor, Graphite Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser CLS21E Memosens Conductivity Sensor,

Answers from our engineering team on installation, compatibility and integration.

01What material are the electrodes of the CLS21E?
The electrodes are graphite, mounted in a PES-GF20 shaft with a titanium socket for the temperature probe.
02What range does the CLS21E measure?
The conductivity range is 10 microsiemens per cm to 20 mS per cm with a nominal cell constant of 1.0 per cm.
03What are the temperature and pressure limits of CLS21E?
The temperature range is minus 20 to 135 °C at 3.5 bar absolute, and pressure reaches 17 bar absolute at 20 °C.
04What threads does the CLS21E offer?
It is offered with a G1 thread or a 1 inch NPT thread for mounting in flow or immersion assemblies.
05Which transmitters can read the CLS21E?
Liquiline CM442, CM444, CM448, CM42 and CM14, via the Memosens cable CYK10.