Brand: Danfoss
Danfoss 132H0717 FC 103 Refrigeration Drive 11 kW IP66
Description
FC 103 11 kW in IP66: a refrigeration drive for rooftop and machine-room duty
Danfoss 132H0717 is an FC-103P11KT4P66H2XGX drive. The VLT Refrigeration Drive FC 103 is the Danfoss variant for compressors, condenser fans and evaporator fans, and this 11 kW (15 HP) code carries a P66 housing: IP66 / NEMA 4X on a backplate. That rating allows the washdown of cold-store plants and installation on a roof where rain and dust are a fact of life.
The store lists a power loss of 278 W and dimensions of 494 x 243 x 261 mm (H x W x D). Net weight is 20.82 kg. The code also includes a B option, the MCB-109 I/O board with real-time-clock back-up, which adds analogue I/O and keeps the clock running during a power outage.
Technical specifications
| Parameter | Specification |
|---|---|
| Danfoss code number | 132H0717 |
| Type code | FC-103P11KT4P66H2XGXXXXSXXXXAXB0CXXXXDX |
| Series | VLT Refrigeration Drive FC 103 |
| Power rating | 11 KW / 15 HP |
| Mains voltage | 380 – 480 VAC |
| Enclosure | IP66 / NAME 4X Backplate |
| RFI filter | RFI filter Class A2 |
| Brake chopper / safe stop | No brake chopper |
| Control panel / display | Graphical Loc. Cont. Panel |
| PCB coating | Not coated PCB |
| Mains option | No Mains Option |
| B option | MCB-109 I/O, RTC Back-up |
| Frame size | B1 |
| Dimensions | 494 x 243 x 261 mm (H x W x D) |
| Power loss | 278 W |
| Net weight | 20.82 kg |
| EAN | = 5714853293605 |
Refrigeration-specific points
The operating instructions for the FC 103 list sleep mode, a smart logic controller and a parameter group for the application. Real-time clock functions are useful for scheduled set-point changes such as night set-back or defrost-linked fan speeds, and the MCB-109 board provides the back-up battery for that clock.
Using a variable-speed drive on a compressor changes the oil return and the lubrication conditions, so check the compressor manufacturer’s minimum speed before enabling a wide speed range.
Mounting and EMC
The H2 RFI filter is class A2, which suits an industrial site but not a residential or light-commercial site. The enclosure is a B1 frame at 494 x 243 x 261 mm. Gland the cables properly, otherwise the IP66 rating is lost at the cable entries; the standard cable entries are used in this code.
Remember the clearances for cooling above and below the heat sink, and avoid direct sun on the housing in the Gulf summer. The guide lists the derating values for temperature and altitude.
Cold-store and rooftop plants often hold a spare drive for each compressor motor size, because a failed drive can stop a whole refrigeration circuit. Keep the parameter backup and the clock settings of the MCB-109 board in the maintenance file. If the plant uses several FC 103 sizes, ask us to quote the family together so that the options and the software versions are consistent across the order.
Projects that use 132H0717 often need related parts from the same manufacturer, such as connectors, mounting parts or spare kits. Mention them in the same enquiry so that compatibility can be checked together rather than discovered on site, when a missing part stops the work.
Ordering notes
Please confirm the application, supply voltage and motor data before ordering. Seven Star LLC is an independent supplier in Muscat and can quote 132H0717. The attached file is the Danfoss FC 103 operating instructions AQ276149416316; related drives are under AC drives.
Datasheets & Documents
- Operating Instructions Danfoss VLT Refrigeration Drive FC 103 Operating Instructions AQ276149416316 (manufacturer, unaltered) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
Related products
Frequently Asked Questions
An FC-103P11KT4P66H2XG refrigeration drive: 11 kW, 380-480 V, IP66 / NEMA 4X backplate, B1 frame, MCB-109 option.
The store lists an I/O board with real-time-clock back-up as the fitted B option.
H2, class A2 according to the store entry.
Only if the cable entries and glands are installed correctly.
The Danfoss FC 103 operating instructions AQ276149416316.

Reviews
There are no reviews yet.