- Automation & ControlView all 1,920 products
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Industrial Computers
- Motor Soft Starters
- Servo Drives
- Pneumatic Cylinders
- Machine Vision
- Automation Software
- Robotics
Brand: Danfoss
Danfoss VACON 20 Compact AC Drive 0.25-18.5 kW
Description
VACON 20 compact AC drive, 0.25 to 18.5 kW
The VACON 20 is a compact machine-level AC drive from Danfoss covering 0.25 kW to 18.5 kW (0.35 to 25 HP) across single-phase and three-phase supplies. It is built for OEM and plant applications where panel space, fast commissioning and a wide choice of supply voltages matter more than a large power range: pumps, fans, conveyors, packaging and washing machines are the typical tasks named by the maker. Seven Star LLC supplies the VACON 20 in Oman and the GCC as an independent supplier in Muscat, and this page explains how the type code is read, which ratings exist and what to specify when requesting a quotation.
Reading the VACON 20 type code
Every VACON 20 drive carries a code in the form VACON0020-3L-0009-4, optionally followed by a version suffix and option codes. The fields are the product name, the input phase count (1L or 3L), the rated output current in amperes, the voltage class digit and, for the cold plate version, the suffix CP.
- 1L / 3L – single-phase or three-phase supply.
- Current field (0001 to 0038) – continuous rated current IN in amperes; 0009 means 9 A.
- Voltage digit – 1 = 105–120 V, 2 = 208–240 V, 4 = 380–480 V, 7 = 520–600 V.
- -CP – VACON 20 Cold Plate version with a flat cooling surface and IP00 rating.
VACON 20 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Danfoss VACON 20 (type code series VACON0020) |
| Power range | 0.25 kW to 18.5 kW (0.35 to 25 HP) |
| Supply voltages | 105–120 V 1-phase (North America); 208–240 V 1-phase and 3-phase; 380–480 V 3-phase; 520–600 V 3-phase (North America); each −15 % to +10 % |
| Input frequency | 45 to 66 Hz |
| Output frequency | 0 to 320 Hz, resolution 0.01 Hz |
| Overload | 1.5 x IN for 1 minute in 10 minutes; 2 x IN for 2 seconds every 20 seconds |
| Control methods | U/f frequency control and open-loop sensorless vector control; induction and permanent magnet motors |
| Switching frequency | 1.5 to 16 kHz, default 4 kHz |
| Braking | Up to 100 % of TN with brake chopper on 3-phase sizes MI2–MI5 and MS2–MS3; dynamic flux braking on all types |
| Ambient temperature | −10 °C to +50 °C at rated current; Cold Plate −10 to +70 °C |
| Enclosure | IP20 for MI1–MI3, IP21 for MI4–MI5, IP00 for Cold Plate |
| Serial interface | Built-in RS485, Modbus RTU |
| Built-in PLC | Programmable to IEC 61131-3 |
How the VACON 20 controls a motor
The drive rectifies the incoming supply to a DC link and rebuilds a variable-frequency, variable-voltage output for the motor. In U/f mode the voltage follows a fixed curve against frequency, which suits fans and pumps with many motors or unknown motor data. In open-loop vector mode the drive estimates motor flux from measured currents to hold torque at low speed, which helps conveyors and machines with stiff starting loads. A unique feature of this family is the built-in PLC: logic written to the IEC 61131-3 standard can run inside the drive and use spare I/O, so a simple sequence does not need a separate controller. The parameter list can also be edited to create application-specific defaults.
I/O, communication and options
The standard I/O includes a 10 V reference, two analog inputs (0–10 V, and 0(4)–20 mA selectable on AI2), six digital inputs, one analog output, one open-collector digital output and two relay outputs, with RS485 Modbus RTU on terminals A and B. An expansion slot accepts option boards, and the maker states that fieldbus options allow connection to systems such as CANopen, DeviceNet and PROFIBUS DP. The Cold Plate version adds STO inputs (Safe Torque Off) rated by the maker to SIL3.
VACON 20 frame sizes and ratings overview
| Frame size | Typical power coverage |
|---|---|
| MI1 (66 x 160 x 98 mm, 0.5 kg) | 0.25–0.55 kW class at 1-phase 208–240 V; 0.37–0.75 kW at 380–480 V |
| MI2 (90 x 195 x 102 mm, 0.7 kg) | 0.75–1.5 kW at 208–240 V and 1.1–2.2 kW at 380–480 V |
| MI3 (100 x 255 x 109 mm, 1.0 kg) | 1.1–2.2 kW at 208–240 V (up to 3 kW three-phase) and 3–5.5 kW at 380–480 V |
| MI4 (165 x 370 x 165 mm, 8 kg) | 4 kW (230 V), 7.5–11 kW (400 V) |
| MI5 (165 x 414 x 202 mm, 10 kg) | 5.5–11 kW (230 V), 15–18.5 kW (400 V) |
| Cold Plate MS2 / MS3 | MS2 0.75–2.2 kW and MS3 3–4 kW at 208–240 V; MS2 0.75–4 kW and MS3 5.5–7.5 kW at 380–480 V |
Current ratings step from 1.7 A (0.25 kW at 230 V) up to 38 A (11 kW at 230 V and 18.5 kW at 400 V). Always confirm the exact current for your motor rather than selecting by kW alone.
VACON 20 selection and ordering checklist
- Supply voltage and phase count, including whether a 105–120 V or 520–600 V North American class is really needed.
- Motor nameplate current, not just kW; choose a drive whose IN covers it with margin for overload duty.
- Duty: light fan or pump load, or constant-torque conveyor requiring the 1.5 x IN overload.
- Mounting: standard air-cooled drive, DIN rail, or Cold Plate for sealed enclosures with a cooled surface.
- EMC level: C2 on 208–240 V and 380–480 V needs the internal +EMC2 option on standard drives; the Cold Plate does not need it.
- Fieldbus option, keypad or door-mount kit, IP21 or NEMA 1 kit, and parameter-copy adapter.
- Built-in choke: available as an option on types of 16 A and above for harmonic filtering to IEC 61000-3-12.
Installation, commissioning and maintenance
Easy-access terminals, DIN rail mounting and the MCA copy adapter, which clones parameters without mains power in the drive, are all aimed at short set-up times on repeated machine builds. Observe derating: full load up to 1000 m, then 1 % per 100 m up to 2000 m (3000 m for Cold Plate). Allow cooling air clearance, keep cable lengths and shielding in line with the manual, and note that some small types (for example 1L-0009-2, 3L-0007-2 and 3L-0011-2) are limited to +40 °C when used with certain enclosure kits. Periodically clear dust from heat sinks and fans and check terminal tightness.
Applications in Oman and the GCC
In Oman and the wider Gulf the VACON 20 is a practical choice for skid-mounted pumps, small ventilation fans, conveyor lines in food and packaging plants, laundry and washing equipment, and water-treatment auxiliaries where a full-size drive is not justified. High ambient temperature in outdoor cabinets makes the +50 °C rating and derating rules important, and dust and humidity favour correct enclosure kits or the sealed Cold Plate concept.
Information to send with an RFQ
- Complete type code or kW, voltage and phase.
- Motor data: rated current, speed, poles, induction or permanent magnet.
- Control and communication requirements, plus option boards.
- Ambient temperature, altitude and enclosure expectations.
- Quantity and delivery location in the GCC.
Documents and quotation
A selection guide for the VACON 20 and VACON 20 Cold Plate is attached on this page and lists ratings, I/O and options.
Send the full type code or your motor and supply data and we will confirm the matching drive and available documents.
Datasheets & Documents
- Datasheet Danfoss VACON 20 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
FAQ
Questions about the Danfoss VACON 20 Compact AC Drive 0.25-18.5 kW
Answers from our engineering team on installation, compatibility and integration.
01What does the number in VACON0020-3L-0009-4 mean?
The 0009 field is the rated continuous output current in amperes, here 9 A. The 3L shows a three-phase supply and the final 4 shows the 380-480 V class.
02Which supply voltages does the VACON 20 cover?
It is offered for 105-120 V single-phase, 208-240 V single-phase and three-phase, 380-480 V three-phase and 520-600 V three-phase, the first and last being North American classes.
03Does the VACON 20 have a built-in PLC?
Yes. Logic written in accordance with IEC 61131-3 can run inside the drive and use unused I/O, which can remove the need for a small external controller.
04What is the VACON 20 Cold Plate version?
It shares control and power design with the standard drive but has a flat metal surface for cooling through a heat sink or liquid-cooled plate. It is IP00 and rated up to 70 degrees C ambient.
05Can the VACON 20 run permanent magnet motors?
Yes, the maker lists support for both induction and permanent magnet motors, with U/f control and open-loop vector control.


















Reviews
There are no reviews yet.