Danfoss 180B3043 APP 1.5 compact seawater pump

The Danfoss 180B3043 is the APP 1.5, the entry size of the APP 1.5–3.5 group of compact axial piston pumps for seawater and brackish-water reverse osmosis. Its displacement is 9.31 cm³ per revolution, its maximum continuous outlet pressure is 83 bar g, and it weighs only 8.6 kg dry in a duplex stainless steel body with NBR seals. Water is the lubricant, so there is no oil to contaminate the permeate. Seven Star LLC supplies the 180B3043 in Oman and the GCC as an independent supplier in Muscat.

Where the larger APP 5.1–10.2 pumps are designed around 1500 rpm motors, the APP 1.5 is a small, fast pump: its speed range runs from 700 to 3450 rpm, so it pairs naturally with a 2-pole motor or a variable frequency drive. It also carries an integrated flushing valve, a feature the 5.1–10.2 group does not have.

Decoding the 180B3043 identification

Element Meaning
APP 1.5 Pump size with 9.31 cm³/rev (0.57 in³/rev) geometric displacement
180B3043 Danfoss code number of the standard version
180B3143 Code number of the ATEX version (Category 2 Zone 1 or Category 3 Zone 2)
Group 1.5–3.5 Six sizes sharing the housing: 1.5, 1.8, 2.2, 2.5, 3.0 and 3.5

180B3043 technical specifications

Parameter Specification
Manufacturer / part number Danfoss 180B3043 (APP 1.5)
Geometric displacement 9.31 cm³/rev (0.57 in³/rev)
Maximum continuous outlet pressure 83 bar g (1200 psig)
Minimum outlet pressure 20 bar g (290 psig)
Inlet pressure, continuous 0.5 to 5 bar g; peak up to 10 bar g
Speed range 700 to 3450 rpm continuous
Flow at maximum pressure 0.53 m³/h at 1000 rpm; 0.79 m³/h at 1500 rpm; 2.80 gpm at 1200 rpm; 4.19 gpm at 1800 rpm
Media temperature 2 to 50 °C
Ambient temperature 0 to 50 °C
Housing and seal Duplex stainless steel, NBR
Connections Inlet and outlet G 3/4 (BSPP) thread, drain M6
Dry weight 8.6 kg
Sound pressure level 77 dB(A) at 1 m
Typical motor 5.5 kW at 3000 rpm and maximum pressure (7.5 HP class)
Footprint with IEC motor 0.15 m²

Why a small APP suits compact RO systems

A 9.31 cm³ pump at 3000 rpm theoretically moves 28 l/min, or about 1.7 m³/h. The datasheet reports 0.79 m³/h at 1500 rpm at maximum pressure, which is 13 l/min against 14 l/min theoretical, a leakage loss of around 6 percent. That behaviour is typical of the axial piston design: output depends on speed and varies little with pressure, so a drive can set flow directly. A single APP 1.5 on a 1500 rpm motor serves a feed flow of under one cubic metre per hour, while at higher speed it can reach two or more times that.

Because the pump is small and light, it can sit on a compact skid or inside a marine or containerised water maker. The G 3/4 connections accept standard high-pressure hose fittings, and the integrated flushing valve lets the user fill and flush the system without a separate bypass line.

Place of 180B3043 in the 1.5 to 3.5 group

Size Code Displacement cm³/rev Flow m³/h at 1000 / 1500 rpm Max speed rpm Typical motor kW
APP 1.5 180B3043 9.31 0.53 / 0.79 3450 5.5
APP 1.8 180B3044 10.04 0.57 / 0.86 3450 5.5
APP 2.2 180B3045 12.52 0.73 / 1.09 3450 7.5
APP 2.5 180B3046 15.35 0.90 / 1.34 3000 7.5
APP 3.0 180B3030 17.70 1.02 / 1.54 3450 11
APP 3.5 180B3032 20.54 1.19 / 1.79 3000 11

The 180B3043 is the smallest of these. Below it, the APP 0.6 to 1.0 pumps (for example 180B3037, the APP 0.8) cover even smaller flows; above it, the APP 5.1 to 10.2 pumps such as 180B3005 take over. All keep the same 83 bar upper pressure rating.

Selection and ordering checklist for APP 1.5

  • Feed flow and recovery, calculated at the coldest and warmest water temperature expected.
  • Operating pressure up to 83 bar g and the end-of-life membrane pressure margin.
  • Fixed-speed or variable-frequency motor, with speed kept within 700 to 3450 rpm.
  • Inlet pressure source: 0.5 to 5 bar g, with a booster pump if the intake is a long suction line.
  • Standard 180B3043 or ATEX 180B3143.
  • Hose or pipe fittings for the G 3/4 connections, and the flange, coupling and bell housing for the chosen motor.

Installation, commissioning and maintenance

Use a bell housing and flexible coupling and keep radial and axial load off the shaft. Fit flexible hoses, an inlet filter with a 10 µm absolute precision depth cartridge, a low-pressure relief valve and an inlet pressure monitoring switch. Because the pump runs at higher speed than larger models, noise and vibration need extra care: use dampers on the frame and avoid rigid pipe connections. The manufacturer expects up to 8000 hours between services when its conditions are met, with an annual inspection and a purpose-designed tool kit. When the pump will stand for more than a day, rotate it for about 10 seconds with permeate; opening the flushing valve alone does not rinse the internals.

Applications in Oman and the GCC for the 180B3043

Small seawater RO units for yachts and workboats in Muscat, remote coastal fishing and tourism sites, offshore platform lifeboat and utility water makers, laboratory-scale pilot plants and brackish-water polishing stages at industrial sites are where a pump this size appears. The ambient limit of 50 °C needs attention in engine rooms and unventilated containers during Omani summers.

Information to send with an RFQ for 180B3043

  • Code 180B3043 and quantity, with ATEX requirement if any.
  • Duty flow, pressure and the water type and temperature.
  • Motor speed and frame, or the drive model that will control the pump.
  • Hose and fitting standards for the connections.
  • Need for service kits or tool kits.

Site conditions in Oman for the 180B3043

Pump selection in Oman has to account for the site, not only the duty point. Process liquids and cooling water can arrive warm in summer, which raises vapour pressure and reduces the available NPSH, so check the NPSH margin of the 180B3043 at the highest expected liquid temperature. Motors on outdoor skids also work in high ambient air, and their rating, enclosure and cooling should match that environment.

For hygienic and process plants in the Gulf, plan the spare parts that wear first, such as seals, O-rings and bearings, and keep the material certificates with the plant records. Sharing the fluid, temperature, flow, head and cleaning regime with the supplier at RFQ stage makes it easier to confirm that the 180B3043 is the right configuration before the order is placed.

Documents and quotation

The Danfoss APP data sheet covering the 180B3043 is attached on this page.

Send the code number 180B3043 and your system data and we will confirm availability and a quotation for Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet Danfoss 180B3043 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.

Danfoss company profile

Founded 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966)
First product Thermostatic expansion valve for refrigeration
Headquarters Nordborg, Denmark
Ownership Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family
Size About 42,000 employees (2023)
Business segments Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics)
Brands in the group VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls

Milestones

  • 1932–1933: First expansion valve; the company is founded in Nordborg.
  • 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
  • 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
  • 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
  • 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
  • 2021: Acquisition of Eaton's hydraulics business.

Choosing Danfoss products

For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.

Where Danfoss products are used

In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.

Danfoss products we list

Family Examples
Variable speed drives and soft starters VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter
Solenoid valves and coils EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil
Pressure switches and thermostats KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101
Pressure transmitters MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2
HVAC and refrigeration valves AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element

Ordering Danfoss products: what we need

Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.

Facts checked against Danfoss's company history pages and published company data, October 2026.

FAQ

Questions about the Danfoss 180B3043 APP 1.5 Compact Seawater RO Pump

Answers from our engineering team on installation, compatibility and integration.

01What is the displacement of the Danfoss 180B3043?
The APP 1.5 has a geometric displacement of 9.31 cm3 per revolution (0.57 in3). Theoretical flow at 1500 rpm is therefore about 14 l/min.
02What speed range does the APP 1.5 allow?
Continuous speed is 700 to 3450 rpm, which suits 2-pole motors and variable frequency drives. Minimum speed is 700 rpm.
03What are the pump connections?
Inlet and outlet are G 3/4 (BSPP) threads and the drain is M6. The pump has an integrated flushing valve.
04What is the pump weight?
The dry weight in the datasheet is 8.6 kg, which allows installation on compact skids and marine water makers.
05Is there an ATEX version?
Yes, the ATEX version of the APP 1.5 carries code number 180B3143, for Category 2 Zone 1 or Category 3 Zone 2 use.