Brand: Hanna Instruments
Hanna HI930 Standard Automatic Potentiometric Titrator
Description
Hanna HI930 standard automatic potentiometric titrator
The Hanna HI930 is a benchtop automatic potentiometric titrator for standard titrations: standardisation, fixed pH or mV endpoints and equivalence-point detection. It combines a burette, stirrer, pH/mV input and temperature input in one 3.6 kg unit with a 5.7 inch colour display. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
The part number is the standard titrator; accessories such as burette size, electrodes and titrants are specified separately, so tell us the intended method when asking for a quotation.
HI930 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Hanna Instruments HI930 |
| Analysis types | Standardisation, fixed pH/mV and equivalence point pH/mV |
| Endpoint modes | Fixed mV; fixed pH; mV equivalence point (first or second derivative); pH equivalence point (first or second derivative) |
| Burette sizes | 5, 10, 25 or 50 mL; resolution 0.001 mL |
| Burette accuracy | ±0.005 mL (5 mL), ±0.010 mL (10 mL), ±0.025 mL (25 mL), ±0.050 mL (50 mL) |
| Burette flow rate | 0.1/0.3 mL to 2 × burette volume per minute |
| Stirrer | Integrated magnetic, 200 to 1400 RPM in 100 RPM steps |
| mV | -2000.0 to 2000.0 mV; 0.1 mV resolution; ±0.1 mV |
| pH | -2.000 to 20.000 pH; 0.1/0.01/0.001 pH; ±0.001 pH; up to five-point calibration |
| Temperature | -5.0 to 105 °C; 0.1 resolution; ±0.1 °C |
| Memory | Up to 15 titration methods; up to 50 titration and pH/mV reports |
| Connections | BNC (pH/ORP), 4 mm banana (reference), RCA (temperature), USB-A for flash drive |
| Display / power | 5.7 in graphical colour display; 100-240 VAC, 50/60 Hz, 0.5 A |
| Size / weight | 315 × 205 × 375 mm; about 3.6 kg with burette |
| Operating environment | 10 to 40 °C, up to 95 % RH |
How the HI930 works
A potentiometric titrator adds titrant from a precision burette while an electrode follows the sample potential. The HI930 monitors pH or mV, and for equivalence-point methods it locates the inflection of the curve using first or second derivative calculation; for fixed-endpoint methods it stops at a preset pH or mV value.
The burette resolution of 0.001 mL and the integrated stirrer, adjustable from 200 to 1400 RPM, keep dosing and mixing repeatable. Methods are stored in the instrument, up to 15 of them, and results can be saved as reports and moved by USB flash drive.
Where HI930 fits: sensors, accessories and related models
Beyond the titrator, a method needs the right electrode (BNC pH/ORP and a banana-socket reference option), a temperature sensor on the RCA input, titrant, standards and sample vessels. The electrode holder offers four multi-purpose slots for titrant tubes, four 12 mm electrode slots and a temperature sensor slot.
Smaller Hanna mini-titrators exist for single applications; the HI930 is the multi-method standard titrator.
HI930 family comparison
| Item | Capability | Detail |
|---|---|---|
| Burette | 4 sizes | 5, 10, 25, 50 mL; 0.001 mL resolution |
| Endpoint | Fixed or equivalence | pH or mV; first or second derivative |
| Storage | Methods and reports | 15 methods; 50 reports; USB flash export |
| Inputs | Electrode and temperature | BNC, 4 mm banana, RCA |
Because burette size sets accuracy (±0.005 mL on the 5 mL burette up to ±0.050 mL on the 50 mL), choose the smallest burette that comfortably holds the expected titrant volume.
Selection and ordering checklist for HI930
- Define the titration method: alkalinity, acidity, redox, chloride and so on, and the endpoint mode
- Choose burette size 5, 10, 25 or 50 mL according to titrant volume
- Confirm electrode type, reference option and temperature sensor
- Quote titrants, standards and reagents locally appropriate for the method
- Plan USB flash drive workflow for reports
- Check bench space and environment: 10 to 40 °C operation
Installation, calibration and maintenance of HI930
Install the burette, prime the titrant lines, fit the electrode and temperature sensor in the holder and confirm that stirring does not splash. Calibrate the pH electrode with fresh buffers before pH-based methods, and standardise titrants on a primary standard using the Standardisation analysis type.
Flush the burette and tubing when changing titrants, keep titrant bottles closed to avoid CO2 pick-up or evaporation, and inspect tubing for crystals and bubbles. Rinse the electrode between runs and verify with a known sample or check standard on a schedule.
Document each method with the titrant concentration, sample volume, stirrer speed and endpoint criterion, so that results are reproducible between operators and shifts. When a new titrant batch is opened, run the standardisation and store the factor before analysing production samples.
Never leave strong titrants in the lines for long periods. At the end of the week, rinse with deionised water or a suitable solvent as appropriate for the titrant, and store the electrode in the recommended solution.
Typical applications of HI930 in Oman and the GCC
In Oman and the GCC, laboratories use standard titrators for water alkalinity and hardness, acidity and caustic strength of process liquors, chloride and salt content, redox titrations in chemical plants and quality checks in food and beverage production. Desalination and power-plant laboratories rely on titration for routine wet chemistry that supports corrosion and scaling control.
Because methods and reports are stored on the instrument and exported by flash drive, a laboratory manager can audit results without connecting the titrator to a network.
Information to send with an RFQ for HI930
- Titration method(s) and sample type
- Burette size(s) required
- Electrodes, temperature sensor and accessories
- Titrants and standards needed
- Delivery location and lead time
- Project or tender reference
Storage, handling and spares for the Hanna HI930
Store the Hanna HI930 in its case in a clean, dry place. Keep probes, electrodes and reagents as described in the user manual, as many of them need a storage solution or have a limited shelf life. In the GCC climate, keep reagents away from heat and direct sun and check expiry dates before use.
- Calibrate the instrument with fresh standards at the interval your procedure requires.
- Rinse probes and sample cells after each use and inspect them for scratches or deposits.
- Keep spare consumables, such as reagents, standards, cuvettes and electrode solutions, in stock.
- Record calibration results so that drift or probe ageing can be seen early.
When you order the Hanna HI930, list the consumables and standards you need in the same RFQ, so the instrument can be used from the day it arrives.
Documents and quotation
The instruction manual for the HI930 is attached on this page for specifications, calibration procedures and maintenance steps.
Send the part number HI930, the quantity and your delivery location and we will reply with availability and a quotation.
Datasheets & Documents
- Manual Hanna HI930 Instruction Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Hanna Instruments is a maker of analytical instruments for water and liquid testing, founded in 1978 in the Padua area of Italy by Oscar and Anna Nardo. Its early breakthrough was the pHep, an affordable pocket-sized pH tester. The company is now led by the founders' children, Martino and Pamela Nardo, with its headquarters in Woonsocket, Rhode Island, and offers more than 3,000 products.
Seven Star LLC is an independent supplier in Muscat. We list Hanna instruments for water, wastewater and laboratory users in Oman and the GCC.
Hanna Instruments company profile
| Founded | 1978, near Padua, Italy, by Oscar and Anna Nardo |
|---|---|
| Headquarters | Woonsocket, Rhode Island, USA |
| Leadership | Martino Nardo and Pamela Nardo |
| Early product | The pHep pocket pH tester |
| Product families | pHep and HI98 waterproof testers, edge benchtop meters, HI83 multiparameter photometers, Checker HC handheld colorimeters, HI931 and HI932 titrators, process controllers, reagents and calibration buffers |
Hanna product series
Portable meters include the HI98190 pH and ORP meter, the HI98192 EC, TDS and salinity meter, the HI98193 dissolved oxygen and BOD meter, the HI98199 pH, EC and DO meter and the HI9829 multiparameter water quality meter.
The HI98703 is an EPA compliant portable turbidity meter, the HI97711 a free and total chlorine photometer and the HI83414 a benchtop turbidity and chlorine meter.
Waterproof portable meters such as the HI98190 and HI98192 suit field use, with automatic temperature compensation and GLP data for audits. Turbidity measurement with the HI98703 follows EPA method 180.1, and the HI97711 photometer measures free and total chlorine for disinfection control.
Where Hanna instruments are used
Drinking water and desalination plants, wastewater treatment, environmental field surveys, aquaculture, cooling water and quality control labs.
Hanna Instruments products we list
Ordering Hanna instruments: what we need
Send the model, the parameters and ranges, the probe and cable length and any reagents or calibration solutions required.
Facts checked against Hanna Instruments' own company story and City of Woonsocket business profile, October 2026.
Browse Hanna Instruments products by category: Portable Test & Measurement.
FAQ
Questions about the Hanna HI930 Standard Automatic Potentiometric
Answers from our engineering team on installation, compatibility and integration.
01What titration types does the HI930 perform?
Standardisation, fixed pH or mV endpoint titrations, and equivalence-point titrations using pH or mV with first or second derivative detection.
02Which burette sizes are supported?
5, 10, 25 and 50 mL, with 0.001 mL resolution and accuracy from 0.005 mL (5 mL) to 0.050 mL (50 mL).
03How many methods and reports can it store?
Up to 15 titration methods, standard or user-defined, and up to 50 titration and pH/mV reports, exportable by USB flash drive.
04What electrodes can be connected?
A BNC socket takes pH and ORP electrodes, a 4 mm banana socket takes a reference electrode, and an RCA socket takes the temperature sensor.
05What is the stirrer range?
The integrated magnetic stirrer runs from 200 to 1400 RPM in 100 RPM steps.


















Reviews
There are no reviews yet.