Hanna HI83326 Pool and Spa Photometer with pH Input

Description

Hanna HI83326 pool and spa photometer with pH probe input

The Hanna HI83326 is a benchtop and portable photometer with 17 built-in methods for pool, spa and recreational water, plus a digital pH electrode input. It covers chlorine, bromine, ozone, chlorine dioxide, cyanuric acid, alkalinity, phosphate, nitrate, iron and copper among others, with a rechargeable battery for field work. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

The model is delivered with sample cuvettes and caps, cuvette cloth, a USB cable and power adapter. Reagents and the digital pH electrode are not included and are ordered separately.

HI83326 technical specifications

Parameter Specification
Manufacturer / part number Hanna Instruments HI83326
Methods 17 photometer methods plus pH (examples: free and total chlorine 0.00 to 5.00 mg/L, bromine 0.00 to 8.00 mg/L, ozone 0.00 to 2.00 mg/L, cyanuric acid 0 to 80 mg/L, alkalinity 0 to 500 mg/L, pH 6.5 to 8.5 by phenol red, phosphate LR 0.00 to 2.50 mg/L, nitrate 0.0 to 30.0 mg/L as NO3-N, iron HR 0.00 to 5.00 mg/L, copper HR 0.00 to 5.00 mg/L)
Light source LEDs with narrow-band interference filters at 525, 575 and 610 nm (3 optical channels)
Absorbance 0.000 to 4.000 Abs; 0.001 resolution; ±0.003 Abs at 1.000 Abs
Bandwidth / wavelength accuracy 8 nm / ±1 nm
Detector / cuvette Silicon photodetector; round 24.6 mm cuvette
pH probe mode -2.00 to 16.00 pH; 0.01 pH; ±0.01 pH; digital pH/temperature electrode (not included)
Logging 1000 readings, log on demand, optional user name and sample ID
Connectivity USB-A host for flash drive; micro-USB-B for power and computer
Display 128 × 64 pixel LCD with backlight
Power 3.7 V Li-polymer rechargeable; more than 500 photometer measurements or 50 hours of pH measurement; 5 V USB adapter
Environment 0 to 50 °C; 0 to 95 % RH non-condensing
Size / weight 206 × 177 × 97 mm; 1.0 kg
Warranty Two years

How the HI83326 works

The photometer shines LED light through a reacted sample in a round cuvette and compares absorbance to a blank. Each method is tied to a specific wavelength channel, reagent set and timer; the HI83326 has three optical channels, so the methods are grouped by those wavelengths. Calculated results are shown in the unit and chemical form specified for the method.

In probe mode, the meter reads a digital pH and temperature electrode with one or two-point calibration, giving a unified instrument for pool water chemistry: chlorine residual, balance (alkalinity, pH, calcium hardness) and stabiliser all on one bench.

Where HI83326 fits: sensors, accessories and related models

Reagents are ordered per method, in the usual HI93xxx and HI937xx sets; the meter must be paired with a Hanna digital pH electrode for probe mode. A CAL Check cuvette set verifies the optical system. For laboratories needing wastewater tests such as COD, the HI83399 has 98 methods and five optical channels.

Connectivity through a USB flash drive and USB cable moves logged readings into spreadsheets.

HI83326 family comparison

Model Methods Optical channels Typical focus
HI83326 17 3 (525, 575, 610 nm) Pool and spa water
HI83399 98 5 (420, 466, 525, 575, 610 nm) Water, wastewater and COD

Choose HI83326 where the method list matches your pool or spa programme. If your work includes COD, heavy metals, silica or wide wastewater chemistry, choose HI83399.

Selection and ordering checklist for HI83326

  • Confirm that the 17 methods cover your parameters
  • Order reagent sets for each parameter
  • Add a Hanna digital pH electrode for probe mode
  • Add CAL Check cuvettes for validation
  • Decide whether battery operation is needed in the field
  • Plan spare cuvettes and caps

Installation, calibration and maintenance of HI83326

Charge the Li-polymer battery or run from the USB adapter, select the method from the menu, follow the on-screen tutorial for sample volume and reagent quantity, and zero with the unreacted sample. Calibrate the pH electrode at one or two points before probe mode use.

Keep cuvettes clean, avoid scratching, and rinse between methods. Store the pH electrode in storage solution and replace it when response degrades. The meter logs readings with user name and sample ID, which supports audit trails for pool-water records.

Run methods in a sensible order to avoid carry-over: for example, take chlorine and pH first on fresh samples, then run cyanuric acid and alkalinity. Free and total chlorine are read on separate fresh samples, and cyanuric acid uses a turbidimetric method, so rinse thoroughly afterwards.

Because pool water in the Gulf is heated by sun and ambient conditions, let hot samples equilibrate and keep reagent bottles out of vehicles where possible.

Typical applications of HI83326 in Oman and the GCC

Resort and hotel pools along the Omani coast, water parks, gymnasiums, residential compounds and facility-management firms use this class of instrument to keep chlorine, stabiliser, alkalinity and pH inside target windows despite strong sun and heavy bather load. The nitrate, phosphate, iron and copper methods extend its usefulness to cooling and process water checks.

Service contractors who maintain many pools can log a visit under a sample ID and export the readings as a record for the client.

Information to send with an RFQ for HI83326

  • Quantity and the list of parameters to be measured
  • Reagent sets required
  • Digital pH electrode and calibration solutions
  • CAL Check cuvettes and spare cuvettes
  • Delivery location and lead time
  • Project or tender reference

Storage, handling and spares for the Hanna HI83326

Store the Hanna HI83326 in its case in a clean, dry place. Keep probes, electrodes and reagents as described in the user manual, as many of them need a storage solution or have a limited shelf life. In the GCC climate, keep reagents away from heat and direct sun and check expiry dates before use.

  • Calibrate the instrument with fresh standards at the interval your procedure requires.
  • Rinse probes and sample cells after each use and inspect them for scratches or deposits.
  • Keep spare consumables, such as reagents, standards, cuvettes and electrode solutions, in stock.
  • Record calibration results so that drift or probe ageing can be seen early.

When you order the Hanna HI83326, list the consumables and standards you need in the same RFQ, so the instrument can be used from the day it arrives.

Documents and quotation

The instruction manual for the HI83326 is attached on this page for specifications, calibration procedures and maintenance steps.

Send the part number HI83326, the quantity and your delivery location and we will reply with availability and a quotation.

Other Models in the Hanna Benchtop Photometer Range

Seven Star LLC supplies models from the Hanna Benchtop Photometer range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Hanna HI83326 Pool and Spa Photometer with pH InputLiquid Analytical SystemsYou are viewing this model
Hanna HI83399 Multiparameter COD Photometer and pH MeterLiquid Analytical SystemsView details
Datasheets & Documents
  • PDF Manual Hanna HI83326 Instruction Manual Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Hanna Instruments is a maker of analytical instruments for water and liquid testing, founded in 1978 in the Padua area of Italy by Oscar and Anna Nardo. Its early breakthrough was the pHep, an affordable pocket-sized pH tester. The company is now led by the founders' children, Martino and Pamela Nardo, with its headquarters in Woonsocket, Rhode Island, and offers more than 3,000 products.

Seven Star LLC is an independent supplier in Muscat. We list Hanna instruments for water, wastewater and laboratory users in Oman and the GCC.

Hanna Instruments company profile

Founded 1978, near Padua, Italy, by Oscar and Anna Nardo
Headquarters Woonsocket, Rhode Island, USA
Leadership Martino Nardo and Pamela Nardo
Early product The pHep pocket pH tester
Product families pHep and HI98 waterproof testers, edge benchtop meters, HI83 multiparameter photometers, Checker HC handheld colorimeters, HI931 and HI932 titrators, process controllers, reagents and calibration buffers

Hanna product series

Portable meters include the HI98190 pH and ORP meter, the HI98192 EC, TDS and salinity meter, the HI98193 dissolved oxygen and BOD meter, the HI98199 pH, EC and DO meter and the HI9829 multiparameter water quality meter.

The HI98703 is an EPA compliant portable turbidity meter, the HI97711 a free and total chlorine photometer and the HI83414 a benchtop turbidity and chlorine meter.

Waterproof portable meters such as the HI98190 and HI98192 suit field use, with automatic temperature compensation and GLP data for audits. Turbidity measurement with the HI98703 follows EPA method 180.1, and the HI97711 photometer measures free and total chlorine for disinfection control.

Where Hanna instruments are used

Drinking water and desalination plants, wastewater treatment, environmental field surveys, aquaculture, cooling water and quality control labs.

Hanna Instruments products we list

Family Examples
Portable Test & Measurement Hanna HI97711 Free and Total Chlorine Po…, Hanna HI98190 Waterproof Portable pH and…, Hanna HI98192 Waterproof Portable EC, Hanna HI98193 Waterproof Portable Dissol…, Hanna HI98199 Portable pH, Hanna HI9829 Multiparameter Water Qualit…, Hanna HI98703 Portable Turbidity Meter

Ordering Hanna instruments: what we need

Send the model, the parameters and ranges, the probe and cable length and any reagents or calibration solutions required.

Facts checked against Hanna Instruments' own company story and City of Woonsocket business profile, October 2026.

FAQ

Questions about the Hanna HI83326 Pool and Spa Photometer with pH Input

Answers from our engineering team on installation, compatibility and integration.

01How many methods does the HI83326 have?
It has 17 photometer methods covering chlorine, bromine, ozone, chlorine dioxide, cyanuric acid, alkalinity, phosphate, nitrate, iron, copper and more, plus a pH probe mode.
02Which wavelengths does it use?
Three LED channels with narrow-band interference filters at 525, 575 and 610 nm, with 8 nm bandwidth and plus or minus 1 nm wavelength accuracy.
03Is a pH electrode included?
No. The digital pH electrode is ordered separately; the meter supplies the input and calibration functions for it.
04How is it powered?
By a 3.7 V Li-polymer rechargeable battery giving more than 500 photometer measurements or 50 hours of pH measurement, or by a 5 V USB adapter.
05Can data be exported?
Yes. It logs 1000 readings and exports through a USB-A flash drive or micro-USB connection to a computer.