BARTEC HYGROPHIL F 5674 Process Trace Moisture Analyzer 5674-xx
Description
Overview
The BARTEC HYGROPHIL F 5674 (HYF 5674) is a process trace moisture analyzer evaluation and control unit designed for continuous, reliable moisture measurement in industrial gas and liquid processing. It works exclusively with BARTEC’s optical L166x measuring sensors connected via fibre-optic hybrid cables.
Reliable trace moisture measurement is essential for process safety, product quality, and asset protection, and the 5674 delivers highly stable readings at very low moisture levels even under demanding conditions such as high pressure or hazardous areas.
Engineering & Design
The HYGROPHIL F 5674 performs signal evaluation of the Fabry-Pérot interferometer optical sensor using secondary optical principles, updating an averaged measurement result in less than 5 seconds for single-channel systems and under 15 seconds for full multi-channel updates.
Available as a single-channel or multi-channel unit supporting 1 to 3 sensor channels, the analyzer accepts interchangeable channel cards for analog current input with intrinsic safety [Ex ia IIC Ga], RTD input, and LED excitation [Ex op is] at 820nm, enabling safe operation with sensors in hazardous zones.
Key Features
- Single-channel or multi-channel (1 to 3) evaluation architecture
- Optical Fabry-Pérot interferometer signal evaluation for trace moisture
- Measurement update in less than 5s (single channel) and 15s (multi channel)
- Analog outputs: 6× 0/4–20mA active, short-circuit proof, 1000 ohm max load
- 6 digital outputs configurable as error or limit channels
- Modbus RTU as standard with optional Modbus TCP/IP
- Intrinsically safe channel cards certified [Ex ia IIC Ga] and [Ex op is]
- 8 freely assignable output channels (TT, SP, WL, VP, RH, DT, FP, PPMv, PPMw, MC)
- Measurement of gaseous or liquid hydrocarbons and other chemical media
- ATEX, IECEx, cCSAus, CE and cTUEVus certified system
- Indoor stationary industrial operation with 19-inch rack integration
Applications
- Natural gas processing and transmission quality monitoring
- LNG production and regasification plants
- Petrochemical and refinery process streams
- Hydrogen infrastructure and specialty gas systems
Specifications
| Model | HYGROPHIL F 5674 (HYF 5674) |
|---|---|
| Sensors | Optical L166x series with fibre-optic hybrid cables |
| Principle | Fabry-Pérot interferometer, secondary optical evaluation |
| Channels | 1 (single) or 1–3 (multi-channel) plus optional pressure sensors |
| Update Time | <5s single channel; <15s multi-channel (all results) |
| Analog Outputs | 6× 0/4–20mA active, max load 1000 ohm, short-circuit proof |
| Digital Outputs | 6 outputs (error channel, limit channel) |
| Communication | Modbus RTU standard, Modbus TCP/IP optional |
| IS Channels | AI 4–20mA [Ex ia IIC Ga], RTD [Ex ia IIC Ga], LED [Ex op is] 820nm |
| Rated Power | AC (IEC 60320 C14) or DC 3-pin terminal input |
| Standards | EN 61000-6-2, EN 61000-6-4, EN 61326-1, EN 55011, FCC Part 15B |
| Certifications | CB scheme, cTUEVus, CE, cCSAus, IECEx, ATEX |
| Mounting | Indoor stationary industrial, rack mounted |
Measurement Range and Accuracy
Per BARTEC’s official product documentation, the HYGROPHIL F 5674 platform, evaluating its Fabry-Pérot interferometer L166x sensors, covers a calibrated dew point range of -80°C to +20°C (-112°F to +68°F) with an accuracy of ±1 K dew point, and can present the result in multiple engineering units — ppmv, ppmw, dew point, frost point, relative humidity, mg/m³, lbs/mmscf, and water vapor pressure — so the same measurement can feed different consumers (a DCS trend, a custody-transfer calculation, a regulatory report) in the unit each one requires without a separate conversion instrument.
Compatibility & Integration
The 5674 integrates into DCS and PLC environments via Modbus RTU or Modbus TCP/IP, with up to 8 freely assignable analog output channels carrying temperature, pressure, dew point, and PPMv/PPMw moisture values.
Selection Notes
Confirm whether your process needs single-channel or multi-channel evaluation, the specific L166x sensor variant matched to your process pressure and temperature, and whether the point requires the intrinsically safe [Ex ia IIC Ga] or optically isolated [Ex op is] channel card, since these determine both the correct HYGROPHIL F 5674 configuration and the compatible sensor part number. Seven Star LLC verifies these details against your process conditions before quotation to ensure the delivered system matches your measurement point exactly.
Engineered Support
Our process analyser specialists support sample conditioning design, L166x sensor selection, and DCS integration via Modbus, plus commissioning assistance from our engineers in Oman for gas processing and petrochemical projects.
Long-term support includes spare part planning for sensor caps, fibre-optic cables, and channel cards so your moisture measurement remains operational.
Operational Benefits
The HYGROPHIL F 5674 gives process engineers continuous, high-resolution trace moisture data that supports product quality control and protects downstream processes from moisture-related corrosion and hydrate formation.
Its fast update time allows operators to react quickly to changing process conditions, while multiple configurable output channels enable direct alarming and trending in the DCS.
Intrinsically safe channel cards expand the range of applications into hazardous areas without complex installation barriers.
For processes that need accurate trace moisture measurement, Seven Star LLC supplies the BARTEC Hygrophil F 5674 with engineering support, and our specialists configure each analyzer for your measurement point.
And the BARTEC Hygrophil F 5674 system is fully documented for your project.
The BARTEC HYGROPHIL F 5674 analyzer measures the trace moisture of the gas and is used for the natural gas quality monitoring.
Why Seven Star LLC
Seven Star LLC supplies genuine BARTEC analyzer systems with engineering support from our Muscat, Oman facility, serving gas processing and petrochemical projects across the GCC.
Our specialists assist with sensor selection, sample conditioning, and commissioning so your trace moisture measurement meets process requirements from day one, drawing on the official BARTEC HYGROPHIL F 5674 documentation for every configuration we quote.
Also available: Bartec EXguard Mobile Gas Detection System
Request a Quote for BARTEC HYGROPHIL F 5674 Process Trace Moisture Analyzer 5674-xx
For the BARTEC HYGROPHIL F 5674, process trace moisture analyzer or any related control and instrumentation requirement, contact the Seven Star LLC team. Submit a formal inquiry through our RFQ page with your measurement range, connection and configuration, and our specialists will respond with a detailed commercial proposal and the official BARTEC documentation.
Related Products
Datasheets & Documents
- Brochure BARTEC HYGROPHIL F 5674 Process Trace Moisture Analyzer 5674-xx Catalog Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Explosion protection is the common thread in everything BARTEC makes. The company was founded in 1975 and is based in Bad Mergentheim, Germany, and its equipment is built to work safely where flammable gas or dust may be present.
Seven Star LLC lists BARTEC process analyzers, Ex enclosures, switching components and hazardous-area tablets, and supplies them to refineries, gas plants and panel builders in Oman by type number.
BARTEC product families on this page
The analyzer group is the largest. Under the HYGROPHIL name there are the HYGROPHIL F 5674 process trace moisture analyzer and the Hygrophil HCDT hydrocarbon dew-point analyzer. Under the BARTEC BENKE name there are the RVP-4 vapor pressure process analyzer and the P-600 salt in crude analyzer. The electrical side is represented by the GUB flameproof Ex d IIC enclosure and the 07-1511 series insert switch, a component used inside control stations. The Agile X IS is a tablet PC for Zone 1, and the EXguard is a mobile gas detection system for hot work.
Where BARTEC equipment is used
Moisture and hydrocarbon dew-point analyzers monitor natural gas at dehydration units, pipeline entry points and custody stations. Vapor pressure and salt in crude analyzers serve refinery blending and crude treatment. Flameproof enclosures and Ex switches go into local control stations, junction boxes and motor starters. Ex tablets are used for inspection rounds and work permits on GCC oil and gas sites.
Ordering BARTEC parts: what we need
BARTEC identifies products by a type number, such as 07-1511-154D/02 or 5674-xx. Send that number in full with the serial number from the label. For analyzers we also need the gas or liquid composition, pressure and temperature at the sample point, the measuring span, the area classification and the signal outputs. For enclosures give the size, the required gas group and temperature class, and the cable entry schedule.
Browse BARTEC products by category: Gas Analyzer Systems, Fire & Gas Detector, Liquid Analytical Systems, Industrial Computer, Automation Accessories.
Related products
Frequently Asked Questions
The unit is designed exclusively for BARTEC L166x optical measuring sensors connected through fibre-optic hybrid cables for trace moisture measurement.
The 5674 is available in single-channel or multi-channel configurations supporting 1 to 3 L166x sensor channels with optional pressure sensors.
It provides 6 active 0/4–20mA analog outputs with up to 1000 ohm load, 6 digital outputs, and Modbus RTU communication with optional Modbus TCP/IP.
Yes, the channel cards carry intrinsic safety certification [Ex ia IIC Ga] and [Ex op is], and the overall system is ATEX, IECEx, and cCSAus certified.
An averaged result updates in under 5 seconds for single-channel systems and under 15 seconds for multi-channel systems.