Brand:

AUMA FQM 05.1 Fail-Safe Unit for SQ 05.2 Actuators

Description

Overview

AUMA FQM 05.1 is the smallest fail-safe unit of the FQM .1 range. It is mounted between a part-turn actuator and the valve and drives the valve to a defined safe position when an emergency shut-down signal or a power failure occurs. The FQM 05.1 is paired with the SQ 05.2 actuator and guarantees a minimum torque of 150 Nm for the fail-safe movement, which matches the top of the SQ 05.2 tripping range.

In Oman and the GCC, Seven Star LLC proudly supplies the AUMA FQM 05.1 to process, power and water customers in Oman and the GCC. For small emergency shut-down valves in Sohar, Salalah and Muscat, we help engineers confirm that the spring unit, the SQ 05.2 actuator and the controls form a coherent safety function.

How the Fail-Safe Movement Works

During normal operation the SQ 05.2 drives the valve through the unit, and the energy store stays charged. When the ESD input, a 24 V DC signal drawing about 1 A, changes state, or when the mains supply fails, the unit releases its stored energy and moves the valve to the preset position. The AUMA FQM 05.1 lets the fail-safe time be set at the factory between 9 s and 34 s for a 90 degree stroke, and AUMA notes that the operating time increases with the torque the valve requires.

The unit works with the SQ 05.2 at operating times of 5.6 s to 32 s in motor operation, so the normal stroke and the emergency stroke can be specified independently. Status is reported by a single switch for each end position, galvanically isolated and rated 0.1 A at 30 V DC, and an output contact signals that the fail-safe function is ready. A rated service life of 500 fail-safe operations (ESD cycles) is documented, which defines the number of emergency actions before overhaul.

Engineering Design of the AUMA FQM 05.1

The valve attachment of the AUMA FQM 05.1 is EN ISO 5211 F07 as standard with F10 as an option, and the splined coupling accepts shafts up to 25.4 mm cylindrical, 22 mm square or 22 mm two-flat. The swing angle is adjustable between 80 and 96 degrees, which is narrower than the standard SQ actuator range because the fail-safe movement has to end at a defined stop.

The unit weighs about 63 kg before the SQ actuator and controls are added, so the tall assembly should be supported on the valve with suitable brackets. Under vibration it is rated 0.3 g with the F07 flange and 0.5 g with F10 across 10 to 200 Hz. Mounting is vertical or horizontal with a support, and a downward-pointing position is excluded. Protection is IP68 with KS coating, and the ambient range of -30 °C to +70 °C (option -40 °C to +60 °C) applies to the standard FQM, whereas the explosion-proof FQMEx 05.1 is limited to -30 °C to +60 °C.

Key Features

The AUMA FQM 05.1 adds an independent mechanical safety layer to a compact part-turn valve.

  • A minimum torque of 150 Nm matches the top of the SQ 05.2 tripping range.
  • Fail-safe time is set at the factory between 9 s and 34 s and lengthens as valve torque rises.
  • Two independent triggers, a 24 V DC ESD input and mains failure, can start the emergency stroke.
  • F07 standard flange with F10 option accepts shafts up to 25.4 mm, which suits compact ball and butterfly valves.
  • Galvanically isolated end position switches and a ready contact feed the safety system.
  • AUMA documents 500 fail-safe operations, which helps plan proof tests and overhaul.
  • The explosion-proof FQMEx 05.1 is covered by a separate AUMA data sheet.
  • IP68 protection and KS coating stand up to coastal installation.

Selection Guidance for the AUMA FQM 05.1

Specifying the AUMA FQM 05.1 starts with the safety function definition. Decide whether the safe position is OPEN or CLOSED, which trigger initiates it, and how fast it must act. The fail-safe time of 9 s to 34 s is set at the factory, so it must be stated at order. Then check that the valve’s torque in the safe direction does not exceed what the unit can deliver, bearing in mind AUMA’s note that the operating time grows with the torque demand.

Finally, confirm the integration: the unit needs a 24 V DC ESD signal, and the SQ 05.2 needs AC actuator controls. Plan the cabinet and cabling accordingly.

Industrial Applications

The AUMA FQM 05.1 serves small emergency isolation valves: fuel supply shut-off, chemical injection stop valves, steam and condensate isolation on small lines, and fire water zone valves where a loss of power must still produce a safe valve position. Because the unit works with the SQ 05.2, it suits skid-mounted packages and compact process modules in industrial zones.

In Oman and the GCC, Seven Star LLC supplies the FQM 05.1 on request with regional technical backing.

Next sizes up: AUMA FQM 07.1, AUMA FQM 10.1 and AUMA FQM/FQMEx fail-safe unit family.

The matching drive belongs to the AUMA SQ part-turn actuator range, the AUMA MATIC AM/AC integral actuator controls supply the controls, and hazardous-area projects pair the explosion-proof FQMEx with the AUMA SQEx explosion-proof part-turn actuator.

Technical Specifications

The data below for the AUMA FQM 05.1 comes from AUMA’s technical data sheet for the FQM 05.1 to FQM 12.1 range and is limited to the standard, non-explosion-proof unit.

Parameter Specification
Model AUMA FQM 05.1 (for SQ 05.2)
Fail-safe operating time 9 – 34 s per 90° (factory setting, rises with torque)
Minimum torque 150 Nm
Suitable actuator SQ 05.2 (5.6 – 32 s)
Valve attachment (EN ISO 5211) F07 standard, F10 option
Valve shaft, max. 25.4 mm cylindrical, 22 mm square, 22 mm two-flat
Weight, approx. 63 kg plus actuator and controls
Vibration resistance, 10 – 200 Hz 0.3 g with F07, 0.5 g with F10
Swing angle 80° to 96°
ESD input 24 V DC, approx. 1 A
Type of duty Open-close S2 – 15 min; modulating S4 – 25 % (not SIL)
Enclosure / corrosion protection IP68 / KS (KX option)
Ambient temperature -30 °C to +70 °C (option -40 °C to +60 °C)
Lifetime 500 fail-safe operations
Explosion-proof version FQMEx 05.1 with SQEx 05.2: -30 °C to +60 °C, ATEX and IECEx per its own sheet

Request a Quote for AUMA FQM 05.1

Tell Seven Star LLC the valve data, safe position, trigger signals and fail-safe time you need for the AUMA FQM 05.1, and our instrumentation division will answer with a formal RFQ response covering the SQ 05.2 and the controls. The technical data sheet can be downloaded from this page. In Oman and the GCC, we supply the AUMA FQM 05.1 on request, with lead time confirmed at quotation.

Datasheets & Documents
  • PDF Datasheet AUMA FQM 05.1 - FQM 12.1 Technical Data (Fail-Safe Unit) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.

Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.

AUMA company profile

Origin Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers.
Headquarters Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide.
Ownership Privately held, owner-managed company: AUMA Riester GmbH & Co. KG
Torque and thrust range Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA
Design principle Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty

Milestones

  • 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
  • Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
  • 1974: AUMA Benelux, the first foreign subsidiary, is founded.
  • Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.

AUMA actuator, controls and gearbox series

Series Type Typical use
SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 Multi-turn actuators, open-close duty Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher
SAR 07.2 to SAR 30.1 Multi-turn actuators, modulating duty Control valves that receive a continuous position setpoint and many starts per hour
SAV, SARV, SQV, SQRV Variable-speed actuators Slow approach to the seat to limit water hammer, fast travel elsewhere
SQ 05.2 to SQ 14.2, SQR Part-turn actuators Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action
SAEx, SAREx, SQEx, PROFOX-MX, TIGRON Explosion-proof actuators Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions
AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL Integral actuator controls AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions
GS, GHE, SA + GS combination Part-turn worm gearboxes Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm
GK, GST, GHT, GP Multi-turn gearboxes (bevel, spur, worm, planetary) Offset or right-angle drives and very high multi-turn torque
LE, SVC/SVCR, PROFOX-L Linear actuators and thrust units Globe and control valves with a rising stem, up to 217 kN
PROFOX-M, PROFOX-Q Compact smart actuators Small valves where a full SA or SQ is oversized
SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN Special versions Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service
SIMA2 Master station Fieldbus network management for many actuators on one plant

Where AUMA actuators are used

Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.

Ordering AUMA actuators and spare parts: what we need

For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.

Facts checked against AUMA product information and the company history published by AUMA, October 2026.

FAQ

Questions about the AUMA FQM 05.1 Fail-Safe Unit for SQ 05.2 Actuators

Answers from our engineering team on installation, compatibility and integration.

01Which actuator does the AUMA FQM 05.1 work with?
AUMA lists the SQ 05.2 as the suitable part-turn actuator, with operating times of 5.6 s to 32 s in motor operation. The explosion-proof FQMEx 05.1 is paired with the SQEx 05.2.
02How fast is the fail-safe movement of the AUMA FQM 05.1?
The fail-safe time can be set in the factory between 9 s and 34 s for 90 degrees, and it increases with the torque the valve requires.
03What triggers the fail-safe function?
An ESD input at 24 V DC or a mains failure, as defined at order. Check the order configuration for the trigger logic.
04How many emergency operations can the AUMA FQM 05.1 perform?
AUMA documents a lifetime of 500 fail-safe operations (ESD cycles) for the FQM range.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC, so every unit is genuine AUMA product supplied with correct documentation and local technical support.