Advantech ADAM-4520-F Isolated RS-232 to RS-422/485 Converter
Description
Overview
The Advantech ADAM-4520-F is an isolated serial converter that connects a device with an RS-232 port to an RS-422 or RS-485 network. It belongs to the ADAM-4000 family of compact RS-485 modules and carries the order code ADAM-4520-F, which the manufacturer lists as the isolated RS-232 to RS-422/485 converter. The unit has a 9-pin female D-sub connector on the RS-232 side and a single plug-in screw terminal block on the RS-422/485 side, so a PLC, a PC COM port, a barcode scanner or a legacy instrument can be extended onto a long multidrop line without replacing the existing equipment.
Seven Star LLC is an independent supplier serving Oman and the GCC. We quote the Advantech ADAM-4520-F against the exact part number so that your maintenance team receives the same suffix that appears in the datasheet.
Why the Advantech ADAM-4520-F suits plant serial networks
RS-232 is a point-to-point interface intended for short cable runs, while RS-485 and RS-422 are differential interfaces designed for long, noisy routes. In pump stations, tank farms, switchrooms and process skids the two worlds often meet, because older analyzers, weighing terminals and controllers still expose only an RS-232 port. The Advantech ADAM-4520-F solves that mismatch with a 3,000 VDC isolation barrier between the two sides, which protects the computer or controller from ground potential differences and induced surges that appear on long field cables.
The module is powered from an unregulated 10 to 30 VDC supply with reversal protection, which matches the 24 VDC control power normally available in an instrument cabinet. Typical consumption is 0.8 W at 24 VDC and the maximum is 1 W, so a single small supply can feed several converters and other ADAM modules.
Key features of the Advantech ADAM-4520-F
- Isolated conversion from RS-232 (DB9 female) to RS-485 two-wire or RS-422 four-wire.
- 3,000 VDC isolation voltage between the serial sides.
- Baud rates of 1,200, 2,400, 4,800, 9,600, 19.2 k, 38.4 k, 57.6 k and 115.2 k bps, selected with a switch.
- RTS control mode and RS-422 mode are also selectable through the same switch bank.
- Power input of 10 to 30 VDC, unregulated, with power reversal protection.
- Compact housing of 102 x 60 x 25 mm.
- Operating temperature of -10 to 70 degrees Celsius.
- Listed as RoHS compliant in the manufacturer datasheet.
Technical specifications of Advantech ADAM-4520-F
| Parameter | Value |
|---|---|
| Order code | ADAM-4520-F |
| Function | Isolated RS-232 to RS-422/485 converter |
| Input interface | RS-232 on a DB9 female connector |
| Output interface | RS-485 two-wire or RS-422 four-wire |
| Field connector | One plug-in terminal block, 14 to 22 AWG |
| Isolation voltage | 3,000 VDC |
| Baud rate settings | 1,200 bps up to 115.2 k bps, plus RTS control and RS-422 switch positions |
| Power input | Unregulated 10 to 30 VDC with reversal protection |
| Power consumption | Typical 0.8 W at 24 VDC, maximum 1 W at 24 VDC |
| Dimensions | 102 x 60 x 25 mm |
| Operating temperature | -10 to 70 degrees Celsius |
| Humidity, operating | 95 percent RH at 40 degrees Celsius, non-condensing |
| Humidity, non-operating | 95 percent RH at 60 degrees Celsius, non-condensing |
How the Advantech ADAM-4520-F differs from other ADAM-4500 series variants
The Advantech ADAM-4520-F shares one datasheet with the ADAM-4510 and ADAM-4510S repeaters, yet its job is different. The repeaters take an RS-485 or RS-422 signal in and regenerate it on a second segment, so both sides are differential. The ADAM-4520-F instead converts between a single-ended RS-232 port and the differential bus. That is why it has a DB9 female connector and only one screw terminal block, whereas the repeaters have two terminal blocks.
The numbers differ as well. The repeaters accept 10 to 48 VDC and the ADAM-4510 is rated for -40 to 85 degrees Celsius, while the converter accepts 10 to 30 VDC and is rated for -10 to 70 degrees Celsius. The ADAM-4520-F housing is 25 mm deep against 27 mm for the repeaters. Its typical power draw of 0.8 W is higher than the 0.2 W typical figure given for the non-isolated ADAM-4510. When a cabinet runs hotter than 70 degrees Celsius, check the temperature class before choosing this converter.
Typical applications in Oman and the GCC
In oil and gas facilities, the converter is commonly used to bring RS-232 devices such as gas chromatograph outputs, tank gauge interfaces and metering skid computers onto an RS-485 multidrop trunk that runs to a control room. Utilities and water operators use the same approach for chlorine analyzers, flow totalizers and legacy telemetry units where the supervisory side expects RS-485. Manufacturing plants apply it to packaging machines, label printers, scales and CNC controllers that still have a COM port but sit tens of metres from the supervisory computer.
The isolation is especially valuable in coastal and desert sites where separate earthing systems and long outdoor cable routes create ground loops. Placing an isolated converter at the device end keeps a lightning-induced surge or an earth fault from damaging the PC serial port.
Selection and compatibility notes for Advantech ADAM-4520-F
Confirm that the host device really uses RS-232 signalling with the usual DB9 pin arrangement, and decide early whether the bus will be two-wire RS-485 or four-wire RS-422, because the output is wired differently in each case. Set the baud rate switch to match the attached equipment. The manufacturer lists RTS control as one switch position, which is useful for software that raises RTS to enable transmission on a half-duplex line.
Check the supply voltage before ordering. The unit tolerates 10 to 30 VDC, so a 24 VDC cabinet supply is suitable, but a 48 VDC supply is outside the stated range. For harsher temperature conditions, compare against other ADAM modules with wider ranges.
Installation and commissioning of the Advantech ADAM-4520-F
Mount the module in a dry, ventilated enclosure and keep it away from heat sources such as power supplies and variable speed drives. Connect the RS-232 cable to the DB9 female socket, land the RS-485 or RS-422 conductors on the terminal block using wire between 14 and 22 AWG, and apply the 10 to 30 VDC supply. Use twisted pair cable for the differential lines and terminate the two physical ends of an RS-485 trunk according to standard practice.
During commissioning set the baud rate with the switches before applying power, confirm communication with a simple read request from the host software, and then lock the settings in your documentation so that a replacement unit can be configured identically.
Maintenance of the Advantech ADAM-4520-F
The converter has no serviceable parts and needs no calibration. Routine checks consist of inspecting the terminal screws for tightness, confirming that the supply voltage stays within 10 to 30 VDC, and verifying that the enclosure temperature remains within the -10 to 70 degrees Celsius operating limit. If communication errors appear, first check the baud rate switch, cable shielding and bus termination before replacing the unit. Keeping a spare Advantech ADAM-4520-F on the shelf shortens downtime for critical serial links.
Related products and ordering notes
Related modules in the same RS-485 family include repeaters and isolated repeaters, as well as digital and analog I/O modules that share the same bus. When you send an enquiry please state the full order code, the quantity, and whether you also need a DIN-rail power supply or other ADAM modules for the same network. We can then reply with availability and lead time.
Related items you may also need: Advantech ECU-1152 Industrial Communication Gateway with 2 x LAN and 6 x COM | Advantech IPC-623 Industrial 4U Rackmount Chassis | Advantech IPC-610-L 4U 15-Slot Rackmount Industrial Chassis | All Advantech products.
Documents and quotation
The manufacturer datasheet for the ADAM-4510, ADAM-4510S and ADAM-4520 family is supplied with this page and gives the connector, isolation, power and environmental data summarised above. To receive a quotation, send an RFQ that includes the part number ADAM-4520-F, the quantity required, your delivery location in Oman or the GCC, and any project reference. Our team will respond with the commercial details.
Datasheets & Documents
- Datasheet Advantech ADAM-4520-F Isolated RS-232 to RS-422/485 Converter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Advantech is the Taiwanese maker of industrial computers and IoT hardware: ADAM remote I/O modules, EKI industrial Ethernet switches and serial device servers, industrial PCs, panel PCs and embedded boards. It was founded in Taipei in 1983 by K.C. Liu and partners, and today Advantech Co., Ltd. is headquartered in Taipei and listed on the Taiwan Stock Exchange.
Seven Star LLC supplies Advantech automation products to system integrators and plant teams in Oman, and this page lists items such as an ADAM-6000 Ethernet I/O module, an ADAM-4000 serial converter and an IPC rackmount chassis.
Advantech company profile
| Founded | 1983, Taipei, Taiwan |
|---|---|
| Founder | K.C. Liu and partners |
| Headquarters | Taipei, Taiwan |
| Ownership | Advantech Co., Ltd., public company listed on the Taiwan Stock Exchange |
| Product families | ADAM-4000 and ADAM-6000 remote I/O, EKI managed and unmanaged switches and serial device servers, industrial PCs and rackmount computers, panel PCs, embedded boards and edge gateways |
Advantech ADAM and IPC products listed here
The ADAM-6017 is an 8-channel analog input module from the ADAM-6000 Ethernet I/O family. It brings voltage and current signals onto a network and is read by SCADA or PLC software over Modbus TCP. The ADAM-4520 belongs to the ADAM-4000 serial family and converts RS-232 to isolated RS-422 or RS-485, a common fix for linking a PC or panel to field devices. The IPC-623 is a 4U, 20-slot rackmount chassis that houses a backplane, CPU card and expansion cards for control room computers.
Advantech products we list
Ordering Advantech hardware: what we need
Send the full part number with its suffix. Advantech adds letters after the model, as in ADAM-6017-D, to mark the hardware revision, and existing configurations sometimes depend on it. For an IPC chassis, state the backplane, power supply and drive bay arrangement, since these are ordered as specific versions. We supply across the GCC and check part numbers against Advantech documentation.
Facts checked against Advantech's published corporate profile, October 2026.
Browse Advantech products by category: Industrial Computer, PLC & I/O Cards, Industrial Communications.
FAQ
Questions about the Advantech ADAM-4520-F Isolated RS-232 to RS-422/485
Answers from our engineering team on installation, compatibility and integration.
01What does the Advantech ADAM-4520-F convert?
It converts an RS-232 signal on a DB9 female connector into RS-485 two-wire or RS-422 four-wire, with 3,000 VDC isolation between the two sides.
02What supply voltage does the ADAM-4520-F need?
It accepts an unregulated 10 to 30 VDC supply with reversal protection and draws about 0.8 W typical and 1 W maximum at 24 VDC.
03Which baud rates can I set on the ADAM-4520-F?
The switch selects 1,200, 2,400, 4,800, 9,600, 19.2 k, 38.4 k, 57.6 k or 115.2 k bps, plus RTS control and RS-422 positions.
04What is the operating temperature of the ADAM-4520-F?
The datasheet lists -10 to 70 degrees Celsius with 95 percent RH at 40 degrees Celsius, non-condensing, which is narrower than the ADAM-4510 repeater.
05How is the ADAM-4520-F different from the ADAM-4510S?
The ADAM-4510S is an isolated RS-422/485 repeater with two terminal blocks, while the ADAM-4520-F has one terminal block and a DB9 RS-232 port.