Schneider Electric CCT15551 Acti9 IHP+ 1C SMARTw Timer
Description
CCT15551 Acti9 IHP+ 1C SMARTw advanced programmable time switch
The CCT15551 is the extended Acti9 IHP+ time switch, in 24 h plus 7 day form with one changeover output. Compared with the plain IHP it adds an external override input, pulse and cycle programming, a random program, a backlit LCD with an operating-time counter and support for a memory stick as optional equipment. It is 45 mm wide on TH35 DIN rail. Seven Star LLC supplies the CCT15551 in Oman and the GCC as an independent supplier based in Muscat.
It allows up to 84 switchings and a minimum interval of 1s, against 56 switchings and 1 min on the plain IHP versions, which matters for process-type and short-pulse tasks.
Where the CCT15551 sits in the IHP range
Choose this model when the application needs short pulses, a manual or building-management override through the external input, or a record of operating hours. For plain weekly schedules the CCT15441 and CCT15443 cover the job with fewer features.
CCT15551 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / CCT15551 |
| Range / product name | Acti9 IHP |
| Product type | Programmable digital time switch |
| Channels | 1 |
| Setting | Weekly programming; Random program 2 |
| Cycle | 24 hours + 7 days |
| Contacts | C/O |
| Output | Dry contact |
| Rated operational voltage | 230 V AC +10 % -15 % at 50/60 Hz |
| Maximum switching current | 10 A – 250 V AC pf = 0.6; 16 A – 250 V AC pf = 1 |
| Minimum switching current | 10 mA 230 V AC; 100 mA 24 V AC/DC |
| Maximum number of switchings | 84 |
| Minimum interval | 1s |
| Accuracy | ± 0.25 s/day 25 °C |
| Power consumption | 0.5 W standby |
| Backup time | 10 years time and program saving |
| Display | Backlit LCD |
| Information displayed | Operating time counter |
| Control buttons | 4 push-buttons |
| Optional equipment | Memory stick |
| Mounting | TH35 DIN rail conforming to EN 60715 |
| Terminals | 2 × 0.5–2.5 mm² screw terminals solid or flexible; 1 × 2.5 mm² screw terminals solid or flexible with sleeve |
| Dimensions | 92.6 mm x 45 mm x 66.7 mm (H x W x D) |
| Net weight | 115 g |
| Insulation class | Class II |
| Overvoltage category | Class 3 |
| Marking | CE |
| Standard | EN 60730-2-7:2010 |
| Operating temperature | -30–55 °C |
| Storage / transport temperature | -30–70 °C |
| Protection | IP20 |
| Relative humidity | 90 %, non-condensing |
| Warranty | 18 months |
Advanced functions of the CCT15551
The datasheet function list is shown below, together with the function row that groups pulse programming, random function and external override input.
- External input for override
- Code lock function
- Holiday schedules
- Automatic winter/summer time changeover
- On/off switching times
- Pulse programming
- Cycle programming
- Switch preselection
A pulse program produces a short output at a set time, useful for bells or dosing pulses; a cycle program repeats on-off periods; and the random function varies switching times to simulate presence. Programs can be backed up with the memory stick listed under available equipment, and time and program are saved for 10 years time and program saving.
CCT15551 in the IHP and IC Astro range
The programmable models from this lane compared on datasheet values:
| Part number | Type | Channels | Max switchings | Min interval | Languages |
|---|---|---|---|---|---|
| CCT15225 | Programmable astronomic twilight switch | 1 | 84 | sunrise/sunset based | 18 |
| CCT15441 | Programmable digital time switch | 1 | 56 | 1 min | 11 |
| CCT15443 | Programmable digital time switch | 2 | 56 | 1 min | 11 |
| CCT15551 (this page) | Programmable digital time switch | 1 | 84 | 1s | 11 |
Loads and contact rating of the CCT15551
The contact is rated 10 A – 250 V AC pf = 0.6 and 16 A – 250 V AC pf = 1 with a minimum of 10 mA 230 V AC and 100 mA 24 V AC/DC. Lamp-load limits from the datasheet:
- incandescent lamp: 2600 W
- halogen lamp: 2600 W
- non-corrected fluorescent tube: 2600 VA
- serial-compensated fluorescent tube: 2600 VA
- parallel compensated fluorescent lamp: 400 VA (48 µF)
- compact fluorescent lamp: 400 W
- < 2 W LED lamp: 25 W
- ≥ 2 W LED lamp: 200 W
Heavier or inductive loads should be switched through a contactor, with the timer driving the coil.
Inrush current at switch-on, particularly with LED drivers and electronic ballasts, can exceed the steady rating for a few milliseconds. The lamp-load limits above already account for typical inrush, but groups of many drivers on one contact should be split or switched through a contactor.
Selection checklist for the CCT15551
- Supply: 230 V AC +10 % -15 % at 50/60 Hz.
- Channels needed: 1.
- Control logic: weekly clock schedule.
- Load: inside the load table or through a contactor.
- Temperature: -30–55 °C operating range.
- Options: override input, memory stick, languages.
Installation and commissioning of the CCT15551
Mount this unit on TH35 rail, wire the supply and load with the 0.5 to 2.5 mm² screw terminals described on the datasheet, then set language, date, time and schedules through the four push-buttons. The unit is Class II, IP20 and overvoltage category 3, so it belongs in a closed board.
After programming, test each output by manual operation, then watch the first scheduled switchings. A code lock function is listed to prevent changes by unauthorised persons, which is worth enabling on shared boards.
Before energising, confirm that the supply on the board matches 230 V AC +10 % -15 % at 50/60 Hz and that the load circuit has its own protective device, since the timer contact is not a short-circuit protection element. Keep control wiring tidy and clear of power cables so the unit’s push-buttons and display remain accessible for later changes, and label the output so maintenance staff know which circuit it controls.
Where the CCT15551 is used in Oman and the GCC
Typical jobs are street, facade, landscape and car-park lighting, mosque and compound lighting, and signage that should follow a daily or weekly routine. In hot and dusty switchrooms keep the board within the -30–55 °C range on the datasheet and avoid direct sun on the enclosure.
In practice many Gulf sites run lighting on a fixed evening-to-dawn pattern all year, and shift pumps, fans or irrigation by season. Document each programmed schedule on a label inside the board door, because a replaced timer comes up blank and the schedule has to be re-entered from the record.
Documents and quotation
The official Schneider Electric datasheet of this unit is attached on this page for download, so every figure above can be checked against the source.
To request a quotation, send us the part number CCT15551, the quantity and the delivery location through the RFQ form. Seven Star LLC replies with availability and lead time.
Other Models in the Se Ihp Programmable Range
Seven Star LLC supplies models from the Se Ihp Programmable range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric CCT15225 Acti9 IC Astro 1C Twilight Switch | Automation Accessories | View details |
| Schneider Electric CCT15441 Acti9 IHP 1C Programmable Timer | Automation Accessories | View details |
| Schneider Electric CCT15443 Acti9 IHP 2C Programmable Timer | Automation Accessories | View details |
| Schneider Electric CCT15551 Acti9 IHP+ 1C SMARTw Timer | Automation Accessories | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric CCT15551 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric CCT15551 Acti9 IHP+ 1C SMARTw
Answers from our engineering team on installation, compatibility and integration.
01What is the CCT15551?
It is a Schneider Electric Acti9 programmable digital time switch with 1 channel(s) and a changeover dry contact, 45 mm wide for TH35 DIN rail.
02What supply voltage does the CCT15551 use?
The datasheet gives 230 V AC +10 % -15 % at 50/60 Hz and a maximum standby power consumption of 0.5 W standby.
03What is the maximum switching current of the CCT15551?
10 A - 250 V AC pf = 0.6; 16 A - 250 V AC pf = 1, with a minimum of 10 mA 230 V AC; 100 mA 24 V AC/DC.
04How long does the CCT15551 keep its program without supply?
The datasheet lists a backup time of 10 years time and program saving.
05How many switchings can the CCT15551 store?
The datasheet gives a maximum of 84 with a minimum interval of 1s.


















Reviews