Brand: ABB
ABB PM583-ETH AC500 Processor Module 1024 kB, Ethernet
Description
PM583-ETH AC500 processor module: the mid-range Ethernet processor of the AC500 V2 family
The ABB PM583-ETH is an AC500 V2 processor module with 24 V DC supply, a memory card slot, a display with function keys, two serial interfaces and an onboard Ethernet TCP/IP port with web server, SNTP and IEC 60870-5-104 protocols. Its ABB order code is 1SAP140300R0271. It doubles the program memory of the PM573-ETH and raises the clock to 84 MHz, which makes it the common choice for process skids and packaged plant where logic, communication and some analog control share one CPU. The ABB data sheet lists it in the Classic life cycle phase, meaning it is available from stock but not recommended for planning new installations; it remains a very common spare and replacement for the large installed base of AC500 V2 systems.
How the PM583-ETH designation is built
| Part of the name | Meaning |
|---|---|
| PM | Processor module of the AC500 PLC |
| 583 | CPU performance class (program memory, clock speed and I/O capacity grow with the number) |
| ETH | Onboard Ethernet 10/100 Base-TX with one RJ45 socket, provided on a TB5x1-ETH terminal base |
An XC variant exists for extreme conditions in other order codes, and the -2ETH variant has two independent Ethernet ports; this page covers only the standard PM583-ETH with order code 1SAP140300R0271.
PM583-ETH technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | ABB / PM583-ETH |
| Order code | 1SAP140300R0271 |
| Program memory (flash EPROM and RAM) | 1024 kB |
| Data memory, integrated | 1024 kB, of which 288 kB is buffered |
| Processor | Freescale ARM 32-bit, 84 MHz |
| Cycle time per instruction | 0.05 µs binary, 0.06 µs word, 0.50 µs floating point |
| Supply voltage | 24 V DC (-15 %, +20 %), reverse-polarity protection |
| Supply connection | Removable 5-pin spring terminal block on the terminal base |
| Current consumption from 24 V DC | 110 mA |
| Serial interfaces | COM1 RS-232/485 (pluggable spring terminal) and COM2 RS-232/485 (D-sub); programming, Modbus master/slave, ASCII, CS31 master on COM1 |
| Ethernet | 10/100 Base-TX, 1 x RJ45 on TB5x1-ETH, web server, SNTP, IEC 60870-5-104 |
| External communication modules | Up to 4 (for example PROFIBUS DP, Ethernet, CANopen) in any combination |
| Maximum central I/O, up to 7 expansion modules | 224 DI, 224 DO, 112 AI, 112 AO |
| Maximum central I/O, 10 expansion modules | 320 DI, 320 DO, 160 AI, 160 AO |
| Data backup | Battery, typically 3 years without supply at +25 °C; low-battery warning about 2 weeks before critical |
| Real-time clock | Battery backed, typically ±2 s per day at +25 °C |
| Memory card | Pluggable card for user data, program storage and firmware update |
| Programming languages | ST, IL, FBD, LD, SFC, CFC |
| Weight (module without terminal base) | 150 g |
| Operating temperature | 0 to +60 °C horizontal mounting; 0 to +40 °C vertical mounting |
| Storage and transport temperature | -40 to +70 °C |
| Humidity | Max. 95 %, no condensation |
| Altitude in operation | Below 2000 m (above 800 hPa) |
| Degree of protection | IP20 for the complete PLC system |
| Mounting | 35 mm DIN rail (7.5 or 15 mm deep) or M4 screws, 1.2 Nm |
| Vibration / shock | 2 to 8.4 Hz 3.5 mm, 8.4 to 150 Hz 1 g; shock 15 g, 11 ms |
Sizing the PM583-ETH for the application
With 1024 kB of program memory, 1024 kB of data memory and an 84 MHz ARM processor, the PM583-ETH handles multi-unit sequencing, several communication modules and moderate PID loop counts. Instruction times of 0.05 µs binary and 0.50 µs floating point give a visible reduction in scan time against the PM573-ETH on the same program.
All figures above come from the ABB data sheet for the PM57x, PM58x and PM59x processor modules. Where this page gives a value for the whole family rather than for one module, it is stated as a family value, so always match the order code on the nameplate to the code in your quotation request.
How the PM583-ETH works with its terminal base
An AC500 V2 processor module does not mount alone. It plugs into a terminal base that carries the 24 V DC supply terminals, the I/O bus connection to the digital and analog modules, the serial interfaces and, on the ETH bases, the RJ45 Ethernet socket. The TB511 base takes one processor module and one communication module, the TB521 and TB523 take one processor module and two communication modules, and the TB541 takes one processor module and four communication modules. For a CPU with onboard Ethernet such as the PM583-ETH, the matching base carries the ETH designation (TB5x1-ETH).
The processor runs the IEC 61131-3 program cyclically, in time-controlled tasks or in multiple tasks, and a user password can protect the program. The display and its eight function keys allow RUN/STOP switching and give access to status and diagnostic messages without a PC. The battery maintains the real-time clock and the buffered data area, and the controller raises a warning roughly two weeks before the battery becomes critical, which gives maintenance time to react.
Compatible and related parts for the PM583-ETH
The PM583-ETH belongs to a family of processor modules that share terminal bases, expansion I/O and communication modules. Closest siblings are PM573-ETH, PM585-ETH and PM591-ETH. It keeps the same 288 kB of buffered data as the PM573-ETH, so retentive data planning is unchanged when moving up. For a faster 400 MHz core, the PM585-ETH has the same 1024 kB program memory with a larger data area.
I/O is added through S500 modules on the I/O bus, for example digital input modules such as DI524, digital outputs such as DO524 and analog modules such as AI523, while PROFIBUS DP, CANopen and further Ethernet communication modules go into the free slots of the terminal base. The AC500 V3 PM5xxx range is a separate platform with different programming software; V2 modules and V3 modules should not be mixed in a quotation without checking the system description.
Selection and ordering checklist for the PM583-ETH
- Confirm the full order code 1SAP140300R0271 and that the existing terminal base is a TB5x1-ETH type.
- Check that the project uses the AC500 V2 programming environment and that the firmware of the replacement is compatible with the stored program.
- Verify that the supply is 24 V DC from a SELV or PELV source; the data sheet requires such sources for the supply and I/O circuits.
- Count the expansion I/O: up to 7 modules give 224 digital inputs and outputs, and up to 10 modules give 320, subject to firmware and software versions.
- Decide whether a memory card, a spare battery and a spare terminal base should be ordered together with the CPU.
- For a replacement, record the communication parameters (IP address, Modbus addresses, CS31 settings) before removal so they can be re-entered.
Installation, commissioning and maintenance of the PM583-ETH
Mount the terminal base on a 35 mm DIN rail or with M4 screws at 1.2 Nm, horizontally where possible so that the 60 °C upper temperature limit applies; vertical mounting limits the ambient temperature to 40 °C. Keep the 24 V DC supply wiring away from power cables, and connect cable shields and the rail to functional earth as described in the ABB installation instructions. The AC500 is a Class II/III device and needs no protective earth connection, but functional earth is important for EMC performance.
During commissioning, load the program through COM1 or Ethernet, check the clock and SNTP settings, and test the RUN/STOP behaviour after a deliberate power interruption. Plan a periodic battery check and replace the battery before the warning appears on long-life installations. Keep a spare processor module and a spare memory card in the panel store for critical lines, because a replaced CPU needs its program and, if used, its firmware version restored.
Typical applications for the PM583-ETH in Oman and the GCC
AC500 V2 controllers with Ethernet are found in water treatment and desalination skids, pumping stations, compressor packages, HVAC and building plant, power auxiliaries and process packages in oil and gas facilities. In Oman and the GCC the main design concerns are heat inside outdoor panels, dust and humidity near the coast. The 0 to 60 °C operating range of the standard module suits air-conditioned or well ventilated panels; for harsher cabinets an XC-class module or a better cooled enclosure should be considered, and condensation must be avoided because the module is specified for 95 % humidity without condensation.
Many plants in the region run older AC500 V2 systems that are still in good working order, and for them the PM583-ETH is mainly a like-for-like spare that avoids a platform migration during a shutdown window.
Ethernet and serial communication on the PM583-ETH
| Interface | Use |
|---|---|
| Onboard Ethernet, RJ45 | Programming, web server, SNTP time synchronisation, IEC 60870-5-104 and further Ethernet services |
| COM1 | Configurable RS-232 or RS-485, 0.3 to 187.5 kBit/s, pluggable spring terminal; programming, Modbus, ASCII, CS31 master |
| COM2 | Configurable RS-232 or RS-485 on a D-sub connector; programming, Modbus, ASCII |
| Communication modules | Up to four modules for PROFIBUS DP, CANopen, further Ethernet and similar networks |
On the CS31 bus, a station count of up to 31 with up to 120 digital inputs and 120 digital outputs each is quoted in the data sheet as an example of decentralised I/O capacity; the real limit depends on the fieldbus used.
Information to send with an RFQ for the PM583-ETH
- Part number PM583-ETH and, if known, the order code 1SAP140300R0271.
- Required quantity and whether a terminal base, memory card or battery is also needed.
- Nameplate photo of the installed module, including firmware or serial data if visible.
- Existing terminal base type and the communication modules fitted.
- Delivery location in Oman or the GCC and required delivery time.
Documents and quotation
The ABB data sheet for the PM57x, PM58x and PM59x processor modules is attached on this page and contains the ordering data, technical data and system data used above. Please check the life cycle phase and your firmware requirements before purchase.
Seven Star LLC supplies industrial automation components in Oman and the GCC. Send the part number PM583-ETH and your quantity, and we will reply with availability and a quotation.
Other Models in the Abb Ac500 V2 Cpu Eth Range
Seven Star LLC supplies models from the Abb Ac500 V2 Cpu Eth range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ABB PM573-ETH AC500 Processor Module 512 kB, Ethernet | PLC & I/O Cards | View details |
| ABB PM583-ETH AC500 Processor Module 1024 kB, Ethernet | PLC & I/O Cards | You are viewing this model |
Datasheets & Documents
- Datasheet ABB PM583-ETH Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB PM583-ETH AC500 Processor Module 1024 kB,
Answers from our engineering team on installation, compatibility and integration.
01How much program memory does the PM583-ETH have?
The PM583-ETH has 1024 kB of program memory (flash EPROM and RAM) and runs on a 84 MHz ARM processor, according to the ABB PM57x/PM58x/PM59x data sheet.
02Does the PM583-ETH have onboard Ethernet?
Yes. It has one 10/100 Base-TX RJ45 port provided on a TB5x1-ETH terminal base, with web server, SNTP and IEC 60870-5-104 protocols. A COM1 and COM2 serial interface are also fitted.
03What supply voltage does the PM583-ETH need?
It needs 24 V DC (-15 %, +20 %) with reverse-polarity protection, fed to a 5-pin spring terminal on the terminal base. Current consumption from 24 V DC is 110 mA.
04How many I/O points can the PM583-ETH control centrally?
With up to 7 expansion modules the data sheet gives 224 digital inputs, 224 digital outputs, 112 analog inputs and 112 analog outputs; with 10 expansion modules the limits rise to 320, 320, 160 and 160.
05Can the PM583-ETH be mounted vertically?
Yes. The module can be mounted horizontally or vertically, but the operating temperature is 0 to +60 degrees C for horizontal mounting and only 0 to +40 degrees C for vertical mounting.