Brand:

SICK PBS2-RB010SG1SSDNMA0Z Pressure Sensor, 0-10 bar, IO-Link, Display

Description

Overview

The SICK PBS2-RB010SG1SSDNMA0Z is an electronic pressure sensor with an integrated four-digit display and switching outputs, from the PBS plus family. It measures gauge pressure from 0 to 10 bar (0 to 145 psi) in liquids and gases and presents the reading on a red 14-segment LED display that can be turned electronically through 180 degrees, so it can be read whichever way the sensor is mounted. The housing itself rotates, 330 degrees between display and electrical connection and 320 degrees between housing and process connection, which lets the installer point the display and the cable exit at the most convenient angles.

What sets this code apart is its output flexibility. The data sheet lists IO-Link, PNP and NPN switching outputs plus a 4 to 20 mA or 0 to 10 V analogue signal, so the same sensor can serve as a switch, a transmitter or an IO-Link device that reports data to a master. The wetted parts are 316L stainless steel, the process connection is G 1/4 A according to ISO 1179-2 and the enclosure rating is IP67.

Seven Star LLC is an independent supplier serving Oman and the GCC. This page uses the manufacturer data sheet for part number 6073951.

Measurement performance of the PBS2-RB010SG1SSDNMA0Z

Accuracy is within plus or minus 0.5 percent of span, including non-linearity, hysteresis and zero and full-scale error, and the non-linearity alone is within plus or minus 0.25 percent of span. The response time is 5 ms or less, which is quick enough for pump protection and for pressure-controlled sequences. Long-term drift is within plus or minus 0.1 percent of span per year, the average temperature coefficient of zero and span is within plus or minus 0.16 percent per 10 K and the minimum service life is 100 million load cycles.

Peak pressures are damped by an integrated pressure port of 0.6 mm, or 0.3 mm at and above 10 bar for the G 1/4 connection to DIN 3852-E, which protects the measuring cell from pulsation and water hammer. The internal transmission fluid is silicone oil, used with the lower pressure ranges. The setting accuracy of the switching outputs is within plus or minus 0.5 percent of span.

Technical specifications of the SICK PBS2-RB010SG1SSDNMA0Z

Parameter Value
Type / part number PBS2-RB010SG1SSDNMA0Z / 6073951
Medium Liquid, gaseous
Pressure type Gauge pressure
Measuring range 0 to 10 bar (0 to 145 psi)
Output signal IO-Link / PNP / NPN plus 4 to 20 mA / 0 to 10 V
Communication IO-Link V1.1
Process connection G 1/4 A (ISO 1179-2)
Wetted parts 316L stainless steel
Process temperature minus 20 to plus 85 degrees Celsius
Display 14-segment red LED, 4 digits, 9 mm, rotatable 180 degrees
Display update 1,000, 500, 200 or 100 ms
Supply voltage 15 V DC to 35 V DC
Current consumption 45 mA without analogue output, 70 mA with analogue output
Total current up to 600 mA including switching current
Connection M12 round connector, 4-pin
Accuracy within plus or minus 0.5 percent of span
Non-linearity within plus or minus 0.25 percent of span
Response time 5 ms or less
Long-term drift within plus or minus 0.1 percent of span per year
Seal NBR (FPM/FKM seal included)
Housing Stainless steel 304 lower body, PC plus ABS head
Enclosure rating IP67
Weight approximately 220 g
Ambient temperature, operation minus 20 to plus 80 degrees Celsius
Shock load 50 g, 6 ms
MTTF 104 years

The data sheet states a maximum ohmic load for the analogue output of 0.5 kOhm or less for 4 to 20 mA and above 10 kOhm for the 0 to 10 V signal.

How PBS2-RB010SG1SSDNMA0Z differs from other PBS plus sensors

The PBS plus family covers many pressure ranges, process connections, output combinations and materials, and each combination carries its own code. The SICK PBS2-RB010SG1SSDNMA0Z is the 0 to 10 bar gauge version with a G 1/4 A connection, IO-Link V1.1 and a display. A sibling for 0 to 6 bar or 0 to 25 bar changes the measuring cell and the overload margin, and a version with a different thread such as NPT is a separate item.

Check also whether the application needs a flush membrane. The data sheet quotes a larger long-term drift of 0.2 percent for ranges at or below 0.6 bar or flush-mounted membranes, which does not apply to this standard pressure port.

Typical applications in Oman and the GCC

Pump skids, compressors, hydraulic units, filter stations and water-treatment plants all use pressure sensors with local display. A technician walking round a pump house can read the line pressure directly on the sensor, while the PLC reads the same value through IO-Link or the analogue output and the switching outputs trip alarms or protect pumps from dry running or blocked discharge.

In oil and gas utilities, cooling water systems and desalination plants the stainless wetted parts withstand most water and air duties. For aggressive media, confirm the compatibility of the 316L parts and the NBR seal, or use the FPM/FKM seal that is included with the sensor.

Installation and setup of the SICK PBS2-RB010SG1SSDNMA0Z

Screw the sensor into a G 1/4 A port using the correct seal, hand-tight first and then to the torque recommended in the operating instructions. Mount it where the medium is not pulsating violently, and avoid mounting upside down on liquid lines where air or sediment may collect in the port. Rotate the housing to bring the display into view, and use the electronic rotation if the sensor must be mounted upside down.

Connect a 15 V to 35 V DC supply to the M12 connector, remembering that the supply must handle the 600 mA total current including switching loads. The sensor has overvoltage protection to 40 V DC, short-circuit protection of the outputs and reverse polarity protection. Use the keys on the head to set switching points, the output mode and the display update rate, or configure through an IO-Link master.

Maintenance of the PBS2-RB010SG1SSDNMA0Z sensor

The sensor has no user-serviceable parts. Check the thread seal and the cable connector for tightness and moisture ingress at plant shutdowns, compare the reading with a reference gauge at zero pressure and a known pressure and replace the sensor if the drift exceeds your tolerance. Keep the operating limits in view: ambient temperature from minus 20 to plus 80 degrees Celsius and process temperature up to plus 85 degrees Celsius.

Record the part number 6073951 in the instrument list so that the same range, outputs and connection can be reordered.

Related items you may also need: SICK GTB6-P4212 G6 Photoelectric Proximity Sensor, M8 Connector | SICK UM30-213113 UM30 Ultrasonic Distance Sensor, 200-1,300 mm | SICK IM18-05BPS-ZC1 M18 Inductive Sensor, 5 mm Flush PNP, M12 Plug | All SICK products.

Documents and quotation

The manufacturer data sheet for the SICK PBS2-RB010SG1SSDNMA0Z is attached to this page and includes the dimensional drawing, wiring and the full performance data.

Send your RFQ with the part number PBS2-RB010SG1SSDNMA0Z, the quantity and the delivery location in Oman or the GCC. Seven Star LLC will check availability of the SICK PBS2-RB010SG1SSDNMA0Z, and connectors and fittings can be added to the same quotation.

Datasheets & Documents
  • PDF Datasheet SICK PBS2-RB010SG1SSDNMA0Z Pressure Sensor, 0-10 bar, IO-Link, Display Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

SICK is the German maker of industrial sensors: photoelectric and proximity sensors, safety laser scanners and light curtains, encoders, distance sensors, code readers and gas analysers. Erwin Sick, an optics engineer, founded it in Munich in 1946, and in 1952 it introduced its first marketable accident-prevention light curtain, which protected press operators by stopping the machine when a hand broke the light beam. The company moved to Waldkirch in the Black Forest in 1956 and is still headquartered there. It is a privately held company, and has been an Aktiengesellschaft (AG) since 1996.

SICK company profile

Founded 1946, Munich, Germany, by Erwin Sick (1909–1988)
Headquarters Waldkirch, Baden-Württemberg, Germany (since 1956)
Ownership Privately held; after the founder's death in 1988 his widow Gisela Sick became the main shareholder. Legal form SICK AG since 1996
Size More than 12,000 employees and group revenue of about EUR 2.3 billion (company figures for 2023)
First breakthrough Accident-prevention light curtain for presses, shown in Hanover in 1952
International growth First foreign subsidiary in France in 1972, United States in 1976; today sales and service companies worldwide
Product families Photoelectric, inductive, capacitive, magnetic and ultrasonic sensors; safety laser scanners, light curtains, safety controllers and relays; encoders and motor feedback systems; distance sensors and LiDAR; barcode and 2D code readers and machine vision; gas analysers, dust and flow measurement for process and emissions monitoring

Milestones

  • 1946: Erwin Sick receives a licence to run his engineering firm in Munich.
  • 1952: The first marketable accident-prevention light curtain is presented in Hanover and goes into series production.
  • 1956: The company moves to Waldkirch with 25 employees.
  • 1972 and 1976: Subsidiaries are founded in France and the United States.
  • 1996: SICK becomes an Aktiengesellschaft.
  • Today: Sensors for factory and logistics automation, machine safety and process analysis, with a large share of revenue outside Germany.

Choosing a SICK sensor

For object detection, the sensing principle comes first. A retro-reflective sensor (WL series) sends light to a reflector and switches when an object breaks the beam; it is reliable over long distances and easy to align. A sensor with background suppression (WTB series) detects an object at a set distance and ignores what is behind it, which suits conveyors with shiny or dark backgrounds. A through-beam pair (WS/WE) gives the longest range and the highest reliability in dust. For transparent bottles and film, use a model built for transparent objects (for example WL12G-3B or WL150-P420). The digits in the code also matter: "P" usually means a PNP output and "N" NPN, and the last digits set the connector or cable. For machine guarding, a safety laser scanner such as nanoScan3 or microScan3 protects an area, while a safety controller such as Flexi Soft combines several safety devices.

Where SICK products are used

In Oman and the GCC, SICK sensors are used in packaging and bottling lines, food and beverage plants, logistics and airport baggage handling, cement and steel plants, ports and cranes, automated warehouses, and on machines built by European OEMs. SICK safety scanners guard robots and automated guided vehicles, and its encoders give position feedback on motors, hoists and conveyors.

SICK products we list

Family Examples
Photoelectric sensors WL12-3P2431, WTB12-3P2431, GTB6-P4211, VL18-4P3240, WL12G-3B2531, WS/WE100, KT5W contrast, W26 IO-Link
Proximity, cylinder and ultrasonic sensors IME12-08NPSZC0S, IME18-05BPSZC0S, MZT8, UM18 4-20 mA, UM30, UFN3 fork
Machine safety nanoScan3, microScan3, S300 Professional, Flexi Soft FX3-CPU1, FX3-XTIO, ReLy OSSD
Encoders and motor feedback DFS60B, AFM60 PROFINET, AFS60 SSI, ATM60 PROFIBUS, SRS50, EFS50
Distance sensors and code readers DT50, DL50, DT35, Lector632

Ordering SICK products: what we need

Send the type code and the 7-digit SICK part number from the label (for example WTB12-3P2431 together with its part number). For a replacement sensor, add the output (PNP or NPN), connection (M8, M12 or cable) and sensing distance. For encoders, add the interface (incremental, SSI, PROFIBUS, PROFINET), resolution and shaft type. For safety scanners, tell us the model and whether the existing configuration needs to be kept.

Frequently requested SICK models: SICK WTB4-3 Miniature Photoelectric Proximity Sensor, SICK IME18-08NPSZW2K Inductive Proximity Sensor, SICK DT35-B15251 Laser Distance Sensor, SICK microScan3 Safety Laser Scanner, SICK RZT7-03ZUS-KWB T-Slot Cylinder Sensor.

Facts checked against SICK's published company history and annual figures, October 2026.

FAQ

Questions about the SICK PBS2-RB010SG1SSDNMA0Z Pressure Sensor, 0-10

Answers from our engineering team on installation, compatibility and integration.

01What is the measuring range of the PBS2-RB010SG1SSDNMA0Z?
It measures gauge pressure from 0 to 10 bar (0 to 145 psi) in liquid or gaseous media.
02What outputs does the PBS2-RB010SG1SSDNMA0Z provide?
The data sheet lists IO-Link V1.1, PNP and NPN switching outputs and a 4 to 20 mA or 0 to 10 V analogue signal.
03What process connection does the PBS2-RB010SG1SSDNMA0Z have?
It has a G 1/4 A male connection according to ISO 1179-2 with 316L stainless steel wetted parts.
04How accurate is the PBS2-RB010SG1SSDNMA0Z?
Accuracy is within plus or minus 0.5 percent of span, with a response time of 5 ms or less and one-year drift within plus or minus 0.1 percent of span.
05What supply does the PBS2-RB010SG1SSDNMA0Z need?
It needs 15 V DC to 35 V DC and an M12 4-pin connection, with total current consumption up to 600 mA including switching current.