Hydac EDS 4448-0250-1-PP-000 Programmable Pressure Switch 250 bar
Description
Hydac EDS 4448-0250-1-PP-000 is the 250 bar programmable pressure switch in the EDS 4448 group. It follows the same mechanical layout as its siblings, with a G1/4 A male port, a stainless cell, an FKM seal and an M12x1 five-pole plug, but its measuring range is 0 to 250 bar. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Detailed overview of EDS 4448-0250-1-PP-000
At 250 bar the unit bridges ordinary industrial hydraulics, which typically run at 160 to 210 bar, and heavier presses. The reserve is generous: overload 500 bar and burst 1000 bar, a ratio of four to one against the burst limit. The set-point step is 0.5 bar, so the 1 percent accuracy limit of 2.5 bar is the dominant error rather than the grid.
Because the programmable electronics replace several fixed-setting switches, a single part number such as EDS 4448-0250-1-PP-000 can cover a whole hydraulic power pack: pump unloading, low-pressure warning and system high-pressure alarm are separated only by the programmed values.
A second consideration is shock. The cell is tested to 100 g for 1 ms and 20 g vibration between 10 and 500 Hz, which covers typical press and pump frames. If the switch hangs on a long stub line, however, resonance may add to the real pressure ripple; fit it on a short, rigid connection rather than on a flexible hose to keep the 8 ms response useful rather than noisy, and avoid mounting near a pulsation source such as a piston pump outlet without a damping orifice.
Highlights
- Range 250 bar; step 0.5 bar; overload 500 bar; burst 1000 bar.
- Programmable N/O or N/C direction.
- Response time 8 ms and 100 million cycles.
- UL listing for limited-energy supply according to the datasheet note.
- Supply 8 to 32 V DC, total current up to 2.025 A.
- M12x1 5-pole connector; mating plug sold separately.
Specifications
| Parameter | Value |
|---|---|
| Model code | EDS 4448-0250-1-PP-000 |
| Material number (catalog) | 920091 |
| Setting range | 0 to 250 bar |
| Overload pressure | 500 bar |
| Burst pressure | 1000 bar |
| Process connection | G1/4 A ISO 1179-2, male |
| Tightening torque | 20 N·m recommended |
| Wetted parts | Stainless steel connection; FKM seal |
| Switching output | 1 PNP transistor output, programmable, N/O or N/C |
| Switching current | 1.2 A maximum with one output |
| Switch-point increment | 0.5 bar |
| Switch point / hysteresis window | 5 to 100 percent / 1 to 96 percent of range |
| Delay times | 8 to 2000 ms in 8 ms steps (HPG 3000) |
| Response time | 8 ms |
| Accuracy | 1 percent FS maximum; 0.5 percent typical |
| Temperature coefficient | 0.02 percent FS per degC typical, 0.03 maximum |
| Repeatability | 0.1 percent FS maximum |
| Long-term drift | 0.3 percent FS per year typical |
| Electrical connection | M12x1 male, 5-pole |
| Pins | 1 +UB, 2 not connected, 3 0 V, 4 output 1, 5 not connected |
| Supply voltage | 8 to 32 V DC, ripple 5 percent or less |
| Current consumption | 25 mA inactive; 2.025 A total maximum |
| Switching cycles | more than 100 million |
| Compensated temperature | -25 to 85 degC |
| Storage temperature | -40 to 100 degC |
| Protection class | IP 67 |
| Vibration / shock | 20 g (10 to 500 Hz) / 100 g (1 ms) |
| Weight | about 145 g |
| Approvals / EMC | CE (EN 61000-6-1/2/3/4); cULus E318391 |
Applications
Hydraulic power units for presses and injection moulding, accumulators in hydraulic lift stations, test rigs and steel-works equipment all use this range. In Oman it appears on shipyard hydraulics, crane power packs and workshop test stands. For corrosive media check the wetted materials, since EDS 4448-0250-1-PP-000 uses stainless steel and FKM only.
How EDS 4448-0250-1-PP-000 differs from the 100 and 400 bar versions
EDS 4448-0100 spans 100 bar with 200 bar overload and 500 bar burst; the 0250 version expands each figure to 250, 500 and 1000 bar. EDS 4448-0400 further extends to 400 bar, 800 bar and 2000 bar with a 1 bar step. The measurement cell and the electronics are identical; only the diaphragm thickness and calibration differ.
Selection
A good rule is to place the set point between 30 and 70 percent of range. For a 210 bar system with a relief at 230 bar, EDS 4448-0250-1-PP-000 is the natural choice. If there are pressure intensifiers, step up to the 400 bar type.
Installation
Check the port for a profile seal seat to DIN 3869, tighten to 20 N·m, plug in and wire with 8 to 32 V DC. Use the HPG 3000 to enter the set points. After setup, remove the programmer and test the switch under pressure.
Maintenance
No periodic adjustment. Record programmed values, verify them yearly and replace the unit if it ever fails to hold 1 percent accuracy. Handle EDS 4448-0250-1-PP-000 with a spanner on the hex only.
Documentation: write the stored values, the delay times and the chosen N/O or N/C direction on the maintenance record, together with the material number 920091. If the unit is later replaced with an identical part, the record lets the technician restore the same behaviour in a few minutes using the HPG 3000.
Installation and Commissioning Planning
Planning ahead shortens downtime when a Hydac EDS 4448-0250-1-PP-000 goes into service. Confirm the available mounting space, cable entry or process connection, and the tools and spare seals needed on the day. Keep the existing configuration or calibration data so the new unit can be set up to match, and check that loop drawings and the asset register are updated after the swap. If the installation has to fit a short shutdown window, tell us the date when you request a quotation so that delivery of the Hydac equipment can be planned around it.
Typical Questions From Maintenance Teams
Maintenance engineers replacing a Hydac EDS 4448-0250-1-PP-000 usually ask whether the new unit is a direct fit, whether settings can be copied from the old one, and whether any accessories must be ordered separately. The answer depends on the exact order code and the generation of the installed pressure switches, so the nameplate details are the best starting point. Send them with your request and we will check the match, point out any differences in connections or options, and list the parts needed so that the job can be finished in one visit.
Frequently asked questions about EDS 4448-0250-1-PP-000
What range does EDS 4448-0250-1-PP-000 cover? 0 to 250 bar, with 500 bar overload and 1000 bar burst.
What is the set-point resolution? 0.5 bar for this range.
Is it an NPN or PNP device? PNP, because the second P of PP selects PNP technology; PN would be NPN.
What mechanical torque is advised? 20 N·m on the G1/4 A male thread.
How do I order it? Submit an RFQ to Seven Star LLC with EDS 4448-0250-1-PP-000 and the quantity.
Documents and quotation
The datasheet of EDS 4448-0250-1-PP-000 accompanies this page. Send an RFQ with EDS 4448-0250-1-PP-000, quantity and delivery point for a response.
Datasheets & Documents
- Datasheet Hydac EDS 4448-0250-1-PP-000 Programmable Pressure Switch 250 bar Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
FAQ
Questions about the Hydac EDS 4448-0250-1-PP-000 Programmable Pressure
Answers from our engineering team on installation, compatibility and integration.
01What range does EDS 4448-0250-1-PP-000 cover?
0 to 250 bar, with 500 bar overload and 1000 bar burst.
02What is the set-point resolution?
The switch-point increment is 0.5 bar for the 250 bar range, per the catalog record.
03Is it an NPN or PNP device?
PNP, because the second P of PP selects PNP technology; PN would be NPN.
04What mechanical torque is advised?
The datasheet recommends 20 N·m on the G1/4 A male thread, applied on the hex.
05How do I order it?
Submit an RFQ to Seven Star LLC with EDS 4448-0250-1-PP-000 and the quantity.


















Reviews