Brand: Danfoss
Danfoss 060B016766 MP54 Differential Pressure Switch
Description
MP54: a differential pressure switch with 60 s relay for compressor oil pressure
The 060B016766 is a Danfoss MP54 differential pressure switch with a thermal time relay (relay release 60 s) and a manual reset on the minimum side. It cuts out when the differential pressure falls, which is the classic oil-pressure protection for refrigeration compressors. The low-pressure side operates over -1 to 12 bar (-15 to 175 psig), the fixed differential is 0.9 bar (13 psi) and the contact differential is 0.2 bar.
The contact is SPDT rated AC15 2 A 250 V and DC13 0.2 A 250 V to EN 60947-5, the enclosure is IP20, the electrical connection is a screwed cable entry Pg 13.5 and the pressure connection is 1/4 in male flare to DIN 8906. Maximum working pressure is 17 bar and the test pressure is 22 bar.
Technical specifications
| Parameter | Specification |
|---|---|
| Danfoss code number | 060B016766 |
| Type | MP54 |
| Adjustment | Cut out for falling pressure |
| Ambient temperature range | -40 C to 60 C |
| Approvals as listed | CCC; CE; CMIM; EAC; GL; LLC CDC EURO-TYSK; LVD; RoHS; RoHS China; TYSK; UKCA |
| Contact differential | 0.2 bar |
| Contact function | SPDT |
| Contact rating | AC15=2 A, 250 V; DC13=0.2 A, 250 V |
| Electrical connection | Screwed cable entry |
| Electrical connection size | Pg 13.5 |
| Electrical connection standard | DIN 40430 |
| Electrical spec. standard | EN 60947-5 |
| EN 60947 electrical properties | Insulation: 250V; Pollution degree: 3; Rated impulse voltage: 4 kV; Short circuit prot, fuse: 2A |
| EN 60947 wiring properties | Flex, ferrules: 0.2-1.0 mm2; Flex, no ferrules: 0.2-1.5 mm2; Solid/stranded: 0.2-1.5 mm2 |
| Enclosure rating IP | IP20 |
| Fixed Differential | 0.9 bar |
| Max. test pressure Pe | 22 bar |
| Maximum working pressure | 17 bar |
| Operat. range LP side Pe | -1 bar to 12 bar |
| Pressure connection size | 1/4 in |
| Pressure connection standard | DIN 8906 |
| Pressure connection type | Flare |
| Pressure Male/Female | Male |
| Refrigerants | R11; R113; R12; R124; R134a; R22; R404A; R407A; R407C; R407F; and others listed in the data sheet |
| Relay release time | 60 s |
| Reset function | Manual Min |
| UL approved refrigerants | R11; R113; R12; R124; R134a; R22; R404A; R407A; R407C; R407F; and others listed in the data sheet |
| Net weight | 0.65 kg |
| EAN | 5702428365475 |
Oil pressure protection and the time delay
When a compressor starts, the oil pressure needs a moment to build, so the MP54 contains a thermal time relay that waits 60 s before it cuts out if the differential does not reach the set value. If the oil pump fails or the filter blocks, the contact opens and stops the compressor; the manual reset forces an operator to look at the cause.
The page lists a long refrigerant range (including R134a, R22, R404A, R407A and R407C) and approvals CCC, CE, CMIM, EAC, GL, LVD, RoHS, TYSK and UKCA. GL (Germanischer Lloyd) approval matters on marine and offshore installations.
Wiring and ordering notes
Connect the LP and oil-pump sides with the capillaries or tubes to the matching connections: the high side is the oil pump outlet and the low side the crankcase. Wire conductors up to 1.5 mm2 as given in the EN 60947 wiring properties. The ambient range is -40 to 60 C.
Check the model: MP54, MP55 and MP55A share a data sheet but differ in the relay time and the reset. This MP54 is the manual-reset version with the 60 s relay. Confirm the supply voltage of the relay and the refrigerant before ordering.
Related Danfoss products: Danfoss 060-001366 KP 44 Dual Pressure Switch G1/4, Danfoss 060-216166 KP 37 Pressure Switch 4-21 bar G1/2, Danfoss 060-315766 KPI 35 Pressure Switch -0.2 to 8 bar, Danfoss 060-110166 KP 1 Low Pressure Switch -0.2 to 7.5 bar, Danfoss 017-523866 RT 200 Pressure Switch 0.2-6 bar and Danfoss 061B023466 MBC 5000 Pressure Switch -0.2 to 10 bar.
Documents and quotation
Attached for download: Danfoss Differential pressure switch MP 54, MP 55 and MP 55A AI203286432950en-000801 (manufacturer, unaltered), the manufacturer’s unaltered PDF. Browse comparable products in pressure instrumentation. To order, send us 060B016766 and the required quantity; Seven Star LLC is an independent supplier based in Muscat.
Datasheets & Documents
- Datasheet Danfoss Differential pressure switch MP 54, MP 55 and MP 55A AI203286432950en-000801 (manufacturer, unaltered) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
FAQ
Questions about the Danfoss 060B016766 MP54 Differential Pressure Switch
Answers from our engineering team on installation, compatibility and integration.
01What is Danfoss 060B016766?
An MP54 differential pressure switch, typically used for compressor oil pressure protection, with a 60 s relay and manual reset.
02What is the fixed differential?
0.9 bar (13 psi), with a contact differential of 0.2 bar.
03What is the pressure connection?
1/4 in male flare to DIN 8906.
04What approvals are listed?
CCC, CE, CMIM, EAC, GL, LVD, RoHS, TYSK and UKCA among others.
05Which document is attached?
The Danfoss differential pressure switch MP 54, MP 55 and MP 55A data sheet AI203286432950en-000801.


















Reviews
There are no reviews yet.