Danfoss 060-122166: a narrow-window KP 36 for 4 to 12 bar duty

Danfoss 060-122166 belongs to the KP 36 group, but unlike the wide 2 to 14 bar KP 36 it has a tightened setting range of 4.0 to 12.0 bar and a fine differential of 0.5 to 1.6 bar. The tight differential is the point of the device: where a process has to hold pressure within a narrow band, a switch that can reopen only 0.5 bar below the cut-out gives much steadier control than the usual 0.7 bar minimum.

It has silver contacts, an automatic reset, an open IP30 housing and a G 1/4 A pressure connector. The product page names air compressors as the application, and that fits well: many plant-air systems run with a 7 to 10 bar band, which sits comfortably inside the 4 to 12 bar window.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The information below is taken from the manufacturer’s datasheet and product page for this code.

What the 060-122166 range and differential mean in practice

On a high-pressure application the contact opens when pressure climbs to the value set on the range scale, and the plant restarts when pressure falls by the differential. With 4 to 12 bar of range and a 0.5 to 1.6 bar differential, a compressor set to stop at 10 bar can be told to restart at 9.4 bar or at 8.4 bar, simply by turning the DIFF spindle.

The datasheet reminds users that for high-pressure switches the restart pressure equals cut-out pressure minus differential, while on low-pressure duty the restart pressure equals cut-out plus the differential. The cut-out value must never be placed at or below absolute vacuum.

Specification table for 060-122166

Parameter Value
Code number 060-122166
Type KP 36 single pressure switch
Setting range (pe) 4.0 to 12.0 bar
Differential 0.5 to 1.6 bar
Permissible operating pressure 17 bar
Maximum test pressure 22 bar
Pressure connection G 1/4 A
Contacts SPDT, silver
Contact load AC-1 16 A 400 V, AC-3 16 A 400 V, AC-15 10 A 400 V, DC-13 12 W 220 V
Reset Automatic
Enclosure IP30 (NEMA 1 on product page)
Ambient -40 to 65 C, 80 C for up to 2 hours
Media temperature -40 to 100 C
Fluid Gaseous media
Net weight 0.3 kg
Approvals listed CE, UL, CCC, EAC, RINA
EAN 5702423146741

Where 060-122166 fits in Gulf industry

Reciprocating and screw compressors in garages, fabrication shops and bottling plants across Oman usually unload and reload inside a few bar. Since this switch has a differential as low as 0.5 bar, it suits small receivers where long dead bands would cause large pressure swings at tool level.

Gas-handling skids use the same idea for low-flow regulators and purge panels. In water treatment, the switch can supervise the air supply that drives pneumatic valves on filter backwash lines. Because the contact is silver and rated 16 A at 400 V, a small motor contactor coil or a pilot lamp can be driven directly.

How 060-122166 differs from other KP 36 variants

Parameter Value
060-110866 KP 36, 2.0 to 14.0 bar, differential 0.7 to 4.0 bar, silver contacts
060-113766 KP 36, 2.0 to 14.0 bar, differential 0.7 to 4.0 bar, gold contacts
060-122166 KP 36, 4.0 to 12.0 bar, differential 0.5 to 1.6 bar, silver contacts
060-114466 KP 36, 4.0 to 12.0 bar, differential 0.5 to 1.6 bar, gold contacts
060-450166 KP 36, 2.0 to 14.0 bar, stainless version in IP55 non-transparent enclosure

The headline difference is the lower end of the range: 4 bar rather than 2 bar. Anyone who needs to set a cut-in at 3 bar must pick another code. In return, the 060-122166 gets a differential that goes down to 0.5 bar instead of 0.7 bar.

Installation of the 060-122166

Fit the unit on a rigid surface with the pressure connector pointing down so that condensate drains away from the bellows. Use the supplied rubber gland for 6 to 14 mm cable; for a metal gland, order the PG 13.5 entry with the code listed in the datasheet. Wire the common terminal 1 and use 1-2 or 1-4 depending on whether a high- or low-pressure action is wanted, as described in the contact table of the datasheet.

After wiring, raise the pressure slowly and read the actual trip with a certified gauge. Lock the setting with the sealing screw if tamper protection is required.

Maintenance and service life of 060-122166

The switch has no field-serviceable parts. The datasheet recommends confirming cut-in and cut-out regularly against an accurate gauge, and the manual trip function is a quick way to verify the wiring. Replace the unit if the bellows leaks, if the range scale no longer agrees with a reference gauge, or if the contacts show welding that persists after the load is corrected.

Ordering notes for the 4 to 12 bar KP 36

Order by the full code 060-122166. Near-identical numbers exist with gold contacts or with different enclosures, so state the contact material and enclosure when you send the enquiry. Typical add-ons are the angle bracket and the IP44 top cover.

Short FAQ

The most common questions concern the lower range limit, the contact metal, and whether liquids are allowed. See the answers in the FAQ block of this page.

Contact function and wiring logic for 060-122166

The contact system is single-pole double-throw. Terminals 1 and 4 close when pressure rises above the setting and open again at cut-out minus differential for a high-pressure circuit, while terminals 1 and 2 provide the opposite action and can serve as a low-pressure or alarm output. This makes the 060-122166 useful where a single switch has to run a compressor contactor and drive a warning lamp at the same time.

Both the datasheet and the product page quote the same electrical envelope: insulation level 400 V, pollution degree 3, rated impulse voltage 4 kV and a short-circuit protection fuse of 16 A, which should be fitted ahead of the switch.

Keep in mind the shock and vibration data. On the back plate or wall bracket the unit is stated to withstand 0 to 1000 Hz at 4 g, which is more than most compressor frames deliver, but the angle bracket is not advised in vibrating locations.

Documents and quotation

The datasheet for the KP and KPI industrial family is included with this listing. To obtain a quotation, send an RFQ with the part number and the quantity you need, and mention the destination.

Datasheets & Documents
  • PDF Datasheet Danfoss 060-122166 KP 36 Pressure Switch 4-12 bar Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.

Danfoss company profile

Founded 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966)
First product Thermostatic expansion valve for refrigeration
Headquarters Nordborg, Denmark
Ownership Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family
Size About 42,000 employees (2023)
Business segments Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics)
Brands in the group VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls

Milestones

  • 1932–1933: First expansion valve; the company is founded in Nordborg.
  • 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
  • 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
  • 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
  • 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
  • 2021: Acquisition of Eaton's hydraulics business.

Choosing Danfoss products

For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.

Where Danfoss products are used

In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.

Danfoss products we list

Family Examples
Variable speed drives and soft starters VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter
Solenoid valves and coils EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil
Pressure switches and thermostats KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101
Pressure transmitters MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2
HVAC and refrigeration valves AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element

Ordering Danfoss products: what we need

Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.

Frequently requested Danfoss models: Danfoss 132B0101 VLT Control Panel LCP 12.

Facts checked against Danfoss's company history pages and published company data, October 2026.

FAQ

Questions about the Danfoss 060-122166 KP 36 Pressure Switch 4-12 bar

Answers from our engineering team on installation, compatibility and integration.

01What is special about Danfoss 060-122166 compared with other KP 36 switches?
It has a 4.0 to 12.0 bar setting range and a differential of only 0.5 to 1.6 bar, which gives tighter pressure control than the 2 to 14 bar KP 36.
02Which contact material does 060-122166 use?
Silver contacts in an SPDT system, rated 16 A at 400 V for AC-1 and AC-3 and 10 A for AC-15 according to the datasheet.
03What is the highest pressure 060-122166 may see?
Permissible operating pressure is 17 bar and the test pressure is 22 bar.
04Can 060-122166 be restarted automatically?
Yes, it has automatic reset, and restart on a high-pressure duty occurs at cut-out minus the differential.
05Is 060-122166 supplied with a metal cable gland?
No, it has a rubber gland for 6 to 14 mm cable; a PG 13.5 screwed entry is a separate accessory.