Brand: Endress+Hauser (E & H)
Endress+Hauser CA80AL Liquiline Aluminum Analyzer for Water Treatment
Description
Why plants buy a CA80AL
Aluminium salts are widely used as coagulants and phosphate precipitants. Endress+Hauser CA80AL lets an operator see how much aluminium remains in the water after dosing, so that dosing can be corrected before the residual breaches a drinking water or discharge limit. The datasheet names two applications: control of phosphate precipitation in wastewater plants and monitoring of precipitants in drinking water and wastewater treatment.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Technical information TI01290C, edition 06.24-00, is the source for the numbers here.
Chemistry of the CA80AL measurement
The sample is buffered to pH 5.8 to 6.0 and catechol violet (pyrocatechol violet) reacts with Al(III) to form a blue complex. The photometer measures absorbance at 568 nm, and a reference signal is subtracted to compensate interference. No cross-sensitivity was seen up to 1000 mg/l chloride and sulfate, 500 mg/l calcium, potassium and sodium, 100 mg/l nitrate, 10 mg/l zinc and 2 mg/l fluoride, while a combined effect was not studied.
CA80AL data table
| Parameter | Value |
|---|---|
| Measured variable | Aluminium Al in ug/l (ppb) |
| Range | 15 to 1000 ug/l |
| Dilution | Optional; factor 5 gives 75 to 5000, 10 gives 150 to 10000, 20 gives 300 to 20000 ug/l |
| Repeatability | Plus or minus 10 ug/l up to 300 ug/l; plus or minus 20 ug/l from 300 to 1000 ug/l |
| Interval | About 10.5 min; adjustable 10 min to 24 h |
| Sample volume | 20.5 ml per measurement without dilution |
| Reagents | RB and RK 60 ul per measurement, about 0.173 l per month at 15 min; RN 100 ul, about 0.288 l per month |
| Standard | About 800 ml per month at 48 h calibration interval |
| Sample | 4 to 40 degrees C, under 50 NTU turbidity, pH below 6 |
| Supply | 100 to 120 / 200 to 240 V AC or 24 V DC; up to 1450 VA |
| Ambient | 5 to 40 degrees C (outdoor version minus 20 to 40) |
| Weight | Cabinet 39.5 kg; open installation 31.5 kg |
How CA80AL differs from CA80FE and CA80AM
The unit is mechanically similar to the other CA80 analyzers but its chemistry is different: CA80AL has one range of 15 to 1000 ug/l in the ppb region, three reagents (RB, RK and RN), and the sample pH requirement below 6. CA80FE for iron works at pH 4.25 with a ferrozine reagent in mg/l, while CA80AM reports ammonium up to 100 mg/l. CA80AL has no cooled version in the datasheet and its power consumption has no cooling figure. Its weights are 39.5 kg for the cabinet and 31.5 kg for open installation, the sample must stay at 4 to 40 degrees C and under 50 NTU, and its two measuring channels are the analyzer main parameter, so a second sampling stream can share one cabinet.
Planning calibration and reagent supply for CA80AL
CA80AL consumes three reagents. RB and RK are used at 60 ul per measurement, equal to about 0.173 l per month at a 15 minute interval, and RN at 100 ul per measurement, about 0.288 l per month. Standard solution adds roughly 0.8 l per month with a 48 hour calibration interval. A shorter measuring interval shortens these figures proportionally, so a plant running the minimum 10 minute interval should keep a spare set. Because the sample must have a pH below 6 for the DIN ISO 10566 method, acidified or buffered samples must be checked before the analyzer is connected.
The same controller can carry one or two analyzer channels, up to four Memosens sensors, analog current inputs and binary inputs, and it talks to the control system through PROFINET, PROFIBUS DP, Modbus or EtherNet/IP.
Practical use at Gulf plants
Water works in Oman that coagulate with aluminium sulfate or polyaluminium chloride, and wastewater plants that precipitate phosphate with aluminium, can place a CA80AL after the clarifier or filter outlet. Measurements every 10.5 minutes allow dose pacing instead of fixed-rate dosing. Tool-free maintenance and one or two measuring channels keep servicing short.
Sample conditioning and extras
The optional CAT810, CAT820 or CAT860 systems provide filtration for turbid samples, and up to four Memosens sensors can be added. The dilution function needs dilution water in addition to the sample: 18 to 22 ml sample and 17 to 21 ml water per measurement.
CA80AL questions answered briefly
What does Endress+Hauser CA80AL measure and how? Aluminium in liquids in ug/l, using catechol violet that forms a blue dye with Al(III) at pH 5.8 to 6.0, read at 568 nm per DIN ISO 10566.
What is the CA80AL measuring range? 15 to 1000 ug/l Al, extendable with an optional dilution function: factor 5 gives 75 to 5000, 10 gives 150 to 10000 and 20 gives 300 to 20000 ug/l.
How often does CA80AL deliver a result? Continuously about every 10.5 minutes, adjustable from 10 minutes to 24 hours.
What sample pH is allowed for CA80AL? The sample pH must be below 6 for the measurement according to DIN ISO 10566:1999.
How much standard does CA80AL use? About 800 ml per month at a calibration interval of 48 hours.
Documents and quotation
The datasheet for CA80AL is attached. Send an RFQ with CA80AL, the channel count, dilution, voltage and fieldbus, and the quantity needed. Please add whether the plant uses aluminium sulfate or polyaluminium chloride and the expected residual range, so we can check that 15 to 1000 ug/l or a diluted span matches the application. Reagents RB, RK and RN, standard solution and cleaner are separate items and can be quoted in the same enquiry, as can CAT810, CAT820 or CAT860 sample conditioning for turbid water. We will reply with availability and lead time for the analyzer and for each consumable.
What to Include in Your Endress+Hauser CA80AL Enquiry
An accurate quotation for the Endress+Hauser CA80AL depends on a few details. Please share the complete part number, any suffix codes for options or approvals, the operating conditions at the installation point, and whether certificates of conformity or test reports must ship with the goods. It also helps to know whether the unit is for planned maintenance, a shutdown or an urgent breakdown, because that decides how it is sourced and shipped. With this information our team can check compatibility with your existing liquid analytical systems and reply with availability and a realistic delivery estimate.
Other Models in the Liquiline Ca80 Range
Seven Star LLC supplies models from the Liquiline Ca80 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser CA80FE Liquiline Dissolved Iron Analyzer | Liquid Analytical Systems | View details |
| Endress+Hauser CA80SI Liquiline Silica Analyzer for Boiler Water | Liquid Analytical Systems | View details |
| Endress+Hauser CA80HA Liquiline Water Hardness Analyzer | Liquid Analytical Systems | View details |
| Endress+Hauser CA80AM Liquiline System Ammonium Analyzer | Liquid Analytical Systems | View details |
| Endress+Hauser CA80AL Liquiline Aluminum Analyzer for Water Treatment | Liquid Analytical Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Endress+Hauser CA80AL Liquiline Aluminum Analyzer for Water Treatment Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser CA80AL Liquiline Aluminum Analyzer
Answers from our engineering team on installation, compatibility and integration.
01What does Endress+Hauser CA80AL measure and how?
Aluminium in liquids in ug/l, using catechol violet that forms a blue dye with Al(III) at pH 5.8 to 6.0, read at 568 nm per DIN ISO 10566.
02What is the CA80AL measuring range?
15 to 1000 ug/l Al, extendable with an optional dilution function: factor 5 gives 75 to 5000, 10 gives 150 to 10000 and 20 gives 300 to 20000 ug/l.
03How often does CA80AL deliver a result?
Continuously about every 10.5 minutes, adjustable from 10 minutes to 24 hours.
04What sample pH is allowed for CA80AL?
The sample pH must be below 6 for the measurement according to DIN ISO 10566:1999.
05How much standard does CA80AL use?
About 800 ml per month at a calibration interval of 48 hours.