CSF48 Liquistation: the sampler you can order in stainless steel

Endress+Hauser CSF48 is a stationary automatic sampler built around an integrated controller with up to four measuring channels and optional Memosens inputs. It automates the withdrawal, distribution and cooled storage of liquid samples at municipal and industrial wastewater plants, laboratories and water management offices. The platform is modular, so analog, binary and relay modules can be added, and a battery backup can keep the sampler running through a power failure.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The datasheet is TI00443C, edition 24.22-00.

CSF48 values from the technical information

Parameter Value
Housing options Polystyrene V0 (standard wastewater), ASA+PC V0 (aggressive industrial atmospheres), stainless steel V2A (1.4301) and stainless steel V4A (1.4571)
Supply 100 to 120 / 200 to 240 V AC plus or minus 10 percent, or 24 V DC plus 15 / minus 9 percent
Power 290 VA on AC versions; 240 W on 24 V version
Dosing Vacuum 20 to 350 ml; peristaltic 10 to 10000 ml; sampling assembly accuracy plus or minus 2 ml
Accuracy / repeatability Plus or minus 5 ml or 5 percent; 5 percent
Suction Vacuum 6 or 8 m; peristaltic 8 m; hose up to 30 m; intake speed above 0.5 m/s
Process Open channel; up to 0.8 bar with valve; Samplefit CSA420 assembly up to 6 bar, DN50 PP flange
Ambient Minus 20 to 40 degrees C with cooling, ASA+PC or stainless; 0 to 40 degrees C otherwise
Cooling 2 to 20 degrees C, 4 degrees C default; automatic defrost
Storage Minus 20 to 60 degrees C
Weights 91 kg plastic without cooling; 101 kg with cooling; 105 kg on castors; 118 kg stainless; 146 kg stainless with stand
Fieldbus HART, PROFIBUS DP, Modbus TCP or RS485, PROFINET, EtherNet/IP

The housing choice matters

Polystyrene suits standard wastewater plants and environmental monitoring but can discolour in sunlight; ASA+PC is recommended for aggressive atmospheres at industrial plants and for outdoor use without a weather cover; V2A stainless steel 1.4301 suits standard applications in treatment plants, while V4A 1.4571 is intended for aggressive industrial atmospheres. Stainless versions weigh 118 kg or, with a stand, 146 kg, so plan the lifting and base accordingly.

How CSF48 differs from CSF34

CSF34 has only the ASA-PC housing, AC supply and a 101 kg refrigerated version; CSF48 expands the range with four housings, the 24 V DC supply, battery backup, an air-circulated sample chamber with inner lining and the Samplefit CSA420 pressurised sampling assembly with plus or minus 2 ml accuracy. For a remote site with unreliable grid power in Oman, the DC supply and battery option can decide the choice. Both share the same pump options, dosing ranges and fieldbus choices.

Samplefit sampling assembly

For pressurised lines, the Samplefit CSA420 assembly takes a sample from piping up to 6 bar through a DN50 polypropylene flange and delivers it with the highest accuracy, plus or minus 2 ml. The datasheet lists installation conditions, including a minimum height difference of 0.5 m between the sample supply and the sampler.

Installing and operating CSF48

  • Fit a customer fuse of suitable rating on the AC version, since there is no power switch.
  • Use a hose with 10, 13, 16 or 19 mm ID for the vacuum pump and 10 mm for the peristaltic pump.
  • Keep the suction line as short as practical; the maximum is 30 m.
  • Observe the cooling module limits: minus 20 to 40 degrees C ambient.
  • Select the dosing mode (with or without pressure) for the sample source.

Spare parts and consumables for CSF48

Suction lines such as the 10 mm ID reinforced PVC line of 10 m with suction head (order number 71111233), pump tubes, dosing system parts and sample bottles are the usual wear items. The conductive dosing system uses stainless steel 1.4404 electrodes, the capacitance sensor uses PSU, and the process seals should be chosen for the medium, with Viton recommended for standard watery samples. The battery backup is an option that has to be selected when the sampler is ordered, so state it in the RFQ if a remote or unstable-grid site is planned.

If the sampler is to act as a small measuring station, the four channel controller can also hold Memosens sensors, for example pH, conductivity or oxygen, and log them alongside the samples, with data available by the service interface or the fieldbus.

Use cases in the GCC

Compliance sampling at effluent discharge, inlet sampling for loading studies, and environmental monitoring at ports or industrial zones all need a reliable refrigerated sampler. The stainless steel housing option is attractive for hot, dusty or chemical sites in Oman and across the Gulf.

CSF48 questions answered briefly

What makes Endress+Hauser CSF48 different from other Liquistation samplers? The datasheet highlights four housing materials, an air-circulating sample chamber with inner lining and an optional battery backup that keeps it running during a power failure.

How is CSF48 powered? 100 to 120 or 200 to 240 V AC at 50/60 Hz, or 24 V DC with plus 15 or minus 9 percent tolerance, drawing 290 VA or 240 W on the DC version.

What ambient temperatures does CSF48 accept? Minus 20 to 40 degrees C with the cooling module or with ASA+PC or stainless housing; 0 to 40 degrees C without cooling or with the polystyrene housing.

How heavy is CSF48? 91 kg for plastic without refrigeration, 101 kg with refrigeration, 105 kg on a castor frame, 118 kg in stainless steel and 146 kg for the stainless steel version with stand.

What dosing accuracy does CSF48 offer with Samplefit? Plus or minus 2 ml with the sampling assembly, compared with plus or minus 5 ml or 5 percent for the vacuum and peristaltic pumps.

Documents and quotation

The datasheet for CSF48 is attached to this page. Send an RFQ with CSF48, the housing material, supply voltage, pump type, bottle set, cooling and battery options and the quantity.

Other Models in the Liquistation Range

Seven Star LLC supplies models from the Liquistation range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser CSF48 Liquistation Stationary Sampler, Four HousingsLiquid Analytical SystemsYou are viewing this model
Endress+Hauser CSF34 Liquistation Stationary Wastewater SamplerLiquid Analytical SystemsView details
Datasheets & Documents
  • PDF Datasheet Endress+Hauser CSF48 Liquistation Stationary Sampler, Four Housings Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser CSF48 Liquistation Stationary

Answers from our engineering team on installation, compatibility and integration.

01What makes Endress+Hauser CSF48 different from other Liquistation samplers?
The datasheet highlights four housing materials, an air-circulating sample chamber with inner lining and an optional battery backup that keeps it running during a power failure.
02How is CSF48 powered?
100 to 120 or 200 to 240 V AC at 50/60 Hz, or 24 V DC with plus 15 or minus 9 percent tolerance, drawing 290 VA or 240 W on the DC version.
03What ambient temperatures does CSF48 accept?
Minus 20 to 40 degrees C with the cooling module or with ASA+PC or stainless housing; 0 to 40 degrees C without cooling or with the polystyrene housing.
04How heavy is CSF48?
91 kg for plastic without refrigeration, 101 kg with refrigeration, 105 kg on a castor frame, 118 kg in stainless steel and 146 kg for the stainless steel version with stand.
05What dosing accuracy does CSF48 offer with Samplefit?
Plus or minus 2 ml with the sampling assembly, compared with plus or minus 5 ml or 5 percent for the vacuum and peristaltic pumps.