Brand: Endress+Hauser (E & H)
Endress+Hauser CSF34 Liquistation Stationary Wastewater Sampler
Description
CSF34 Liquistation: a stationary sampler with its own controller and Memosens inputs
Endress+Hauser CSF34 is an automatic stationary sampler for the fully automated removal, defined distribution and temperature-controlled storage of liquid media. Its integrated controller has up to four measuring channels with digital Memosens technology, two 0/4 to 20 mA analog inputs, two binary inputs and two binary outputs as standard, so the same cabinet can act as a small measuring station while it takes samples. The two-door housing is made of ASA-PC plastic and has a forced-air cooling system with a protective finish.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The datasheet is TI00478C, edition 09.22-00.
CSF34 performance data
| Parameter | Value |
|---|---|
| Pump options | Vacuum pump; peristaltic pump; sampling assembly |
| Dosing volume | Vacuum 20 to 350 ml; peristaltic 10 to 10000 ml |
| Dosing accuracy / repeatability | Plus or minus 5 ml or 5 percent; 5 percent |
| Intake speed | Above 0.5 m/s for up to 13 mm ID per EN 25667, ISO 5667, CEN 16479-1; above 0.6 m/s for 10 mm per Oe 5893 and US EPA |
| Suction height | Vacuum 6 or 8 m depending on version; peristaltic 8 m |
| Hose length | Up to 30 m |
| Intake hose ID | Vacuum 10, 13, 16 or 19 mm; peristaltic 10 mm |
| Process pressure | Unpressurised open channel; up to 0.8 bar with shutoff valve; sampling assembly up to 6 bar |
| Supply | 100 to 120 / 200 to 240 V AC plus or minus 10 percent, 50/60 Hz; 290 VA; no power switch, 10 A customer fuse |
| Cooling | 2 to 20 degrees C, 4 degrees C default; automatic defrost |
| Protection | Front dosing IP 54; rear dosing IP 33; display IP 65; sample compartment IP 54; overall IP 33 |
| Storage temperature | Minus 20 to 60 degrees C; humidity 10 to 95 percent |
| Fieldbus | HART, PROFIBUS DP, Modbus TCP or RS485, PROFINET, EtherNet/IP |
| Housing | ASA+PC V0 with PP chamber lining, EPS Neopor insulation, coated safety glass window |
| Weight | 101 kg (plastic with refrigeration) |
How the two pump modes take a sample
With the vacuum pump the sequence is blow clear, intake, dose and drain. A conductive or capacitance dosing system detects the level in the measuring jug; the capacitance type copes with foam, fatty media and conductivity under 30 uS/cm, where only capacitance detection works. Dosing without pressure is the factory setting for open channels and gravity lines; dosing with pressure suits low suction height, small volumes or viscous samples. The peristaltic pump rinses, takes in and drains in three steps, learns the suction height automatically and may rinse the line up to three times before sampling.
How CSF34 differs from CSF48
CSF34 uses a single ASA-PC housing material and offers fewer options than the CSF48, which can be ordered in four housing materials including stainless steel and with a battery backup. CSF34 supply is the AC range only, while CSF48 also lists a 24 V DC supply. CSF34 is documented with 101 kg for the refrigerated plastic version, where CSF48 ranges from 91 kg to 146 kg depending on housing and stand. Dosing is similar, but the sampling-assembly accuracy of plus or minus 2 ml is quoted only in the CSF48 datasheet.
Sampling programs and logging
- Time-paced sampling with the vacuum pump, event sampling, single and multiple samples and a sampling table.
- Integrated data logger and a service interface for data transfer.
- Navigator and large display for menu guidance.
- PE or glass bottles, for example 2 x 12 bottles of 1 litre PE on dual bottle trays.
- Temperature sensors for sampling compartment, with optional sample and outside temperature sensors.
Accessories and sample handling for CSF34
Sampling starts with the suction line: the datasheet lists, for example, a 10 mm ID reinforced PVC suction line of 10 m with a suction head under order number 71111233, and other lengths and diameters are available for the vacuum and peristaltic versions. Sample bottles are PE or glass, in trays that can be lifted out for transport to the laboratory, and a distribution arm moves over the bottles according to the program. A window in the door lets staff see the bottle state without opening the compartment, which helps keep the cooled air in. Conductivity sensors in the dosing system are made of stainless steel 1.4404, the capacitance sensor is PSU, and the process seals should be selected for the application, with Viton recommended for standard watery samples.
CSF34 in Oman wastewater and environmental work
Municipal and industrial treatment plants must show compliance with discharge limits, and a refrigerated composite sampler at inlet and outlet is the standard tool. The ASA-PC housing resists sun fading better than polystyrene, which the datasheet says can discolour in direct sunlight, so it is the better choice outdoors. Provide a weather cover for open sites.
CSF34 questions answered briefly
What pumps can Endress+Hauser CSF34 use? A vacuum pump with dosing system for 20 to 350 ml samples or a peristaltic pump for 10 to 10000 ml samples, plus a sampling assembly version for pressurised lines up to 6 bar.
What cooling does CSF34 provide? An optional cooling module holds samples between 2 and 20 degrees C with a 4 degrees C factory setting, an automatic defrost system and a 4 litre cool-down from 20 to 4 degrees C in under 210 minutes.
How accurate is CSF34 dosing? Plus or minus 5 ml or 5 percent of the set volume for vacuum and peristaltic pumps, with 5 percent repeatability.
What suction capability does CSF34 have? Up to 6 or 8 m suction height with the vacuum pump depending on version, up to 8 m with the peristaltic pump, and up to 30 m of hose.
What does the CSF34 weigh? The plastic version with refrigeration weighs 101 kg.
Documents and quotation
The datasheet for CSF34 is attached. Send an RFQ with CSF34, the pump type, bottle configuration, cooling, hose diameter and quantity for a quotation.
Other Models in the Liquistation Range
Seven Star LLC supplies models from the Liquistation range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser CSF48 Liquistation Stationary Sampler, Four Housings | Liquid Analytical Systems | View details |
| Endress+Hauser CSF34 Liquistation Stationary Wastewater Sampler | Liquid Analytical Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Endress+Hauser CSF34 Liquistation Stationary Wastewater Sampler Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser CSF34 Liquistation Stationary
Answers from our engineering team on installation, compatibility and integration.
01What pumps can Endress+Hauser CSF34 use?
A vacuum pump with dosing system for 20 to 350 ml samples or a peristaltic pump for 10 to 10000 ml samples, plus a sampling assembly version for pressurised lines up to 6 bar.
02What cooling does CSF34 provide?
An optional cooling module holds samples between 2 and 20 degrees C with a 4 degrees C factory setting, an automatic defrost system and a 4 litre cool-down from 20 to 4 degrees C in under 210 minutes.
03How accurate is CSF34 dosing?
Plus or minus 5 ml or 5 percent of the set volume for vacuum and peristaltic pumps, with 5 percent repeatability.
04What suction capability does CSF34 have?
Up to 6 or 8 m suction height with the vacuum pump depending on version, up to 8 m with the peristaltic pump, and up to 30 m of hose.
05What does the CSF34 weigh?
The plastic version with refrigeration weighs 101 kg.