Brand: Endress+Hauser (E & H)
Endress+Hauser CA80HA Liquiline Water Hardness Analyzer
Description
CA80HA keeps an eye on hardness breakthrough
Endress+Hauser CA80HA is a wet-chemical total hardness analyzer. The datasheet describes three uses: optimising reverse osmosis systems and ion exchangers, classifying the hardness level of drinking water, and guaranteeing process water quality in production plants. With a measuring range of 0 to 80 mg/l CaCO3 it is best at the low-hardness end where softener breakthrough shows first.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The datasheet is TI01352C, edition 06.24-00.
How the hardness reaction runs
MgEDTA is added to the sample and exchanges its magnesium for calcium in the same ratio. The freed magnesium reacts with phthalein purple in the basic range to form a violet dye whose absorbance at 568 nm is proportional to total hardness. A reference measurement is subtracted and the photometer temperature is held constant. Chloride up to 1200 mg/l, sodium up to 785 mg/l, bicarbonate 78 mg/l, sulfate 2.4 mg/l, iron(III) 2 mg/l, iron(II) 1.4 mg/l and nitrate 0.9 mg/l showed no interference in the test, with the caveat that combined effects were not studied.
CA80HA numbers
| Parameter | Value |
|---|---|
| Variable | Total hardness as CaCO3 |
| Range | 0 to 80 mg/l |
| Dilution | Factors 5, 10, 20 give 0 to 400, 800, 1600 mg/l |
| Repeatability | Plus or minus 0.3 mg/l; with dilution 5 an extra 1.5 percent of end of range |
| Interval | About 7 min; adjustable 10 min to 24 h |
| Sample volume | 14.7 ml per measurement; with dilution 11 to 15 ml plus 17 to 21 ml dilution water |
| Reagent | 75 ul per measurement; about 90 days at 10 min |
| Standard | 27 ml per calibration; about 270 ml per month at 72 h |
| Calibration interval | 1 hour to 90 days |
| Supply | 100 to 120 / 200 to 240 V AC or 24 V DC; 130 VA plus hose heaters, up to 1450 VA with cooling |
| Cable entries | 4 x M16, G3/8 or NPT3/8; 4 x M20, G1/2 or NPT1/2 |
| Ambient | 5 to 40 degrees C, humidity 10 to 95 percent |
| Weight | Cabinet 42 kg; open 34 kg; analyzer stand 75 kg |
Where CA80HA differs from its siblings
The CA80HA reads in the lowest practical decade for softeners and RO feed, up to 80 mg/l, whereas CA80AM and CA80FE cover other ions. It carries the cooled option for longer reagent life, like CA80AM, and its datasheet quotes about 90 days of reagent at a 10 minute interval. Dilution factors differ: CA80HA offers 5, 10 and 20 on a base range of 80 mg/l, CA80AM offers 2, 4, 10 and 20 on 50 mg/l NH4-N. The weight of the cabinet version is 42 kg, matching the cooled CA80AM, and an analyzer stand version of 75 kg is also listed, which none of the lighter analyzers in this group quote in their weight tables.
Typical placements in the GCC
- Downstream of water softeners protecting boilers and cooling systems.
- On RO feed or permeate lines to see scaling potential.
- At drinking water points where hardness classification is required.
- In food and beverage plants where process water quality is audited.
- On demineralisation lines using demineralised dilution water when hardness is low.
Dilution and calibration planning for CA80HA
When hardness exceeds the 80 mg/l range, the optional dilution module mixes 11 to 15 ml of sample with 17 to 21 ml of dilution water, depending on the factor, so that factors 5, 10 and 20 extend the measured span to 400, 800 and 1600 mg/l. Use demineralised water for dilution when the expected sample hardness is below 50 mg/l, because tap water would itself add hardness. Without dilution each measurement uses 14.7 ml of sample. A calibration uses 27 ml of standard, so a 72 hour interval consumes about 270 ml per month, and the reagent set lasts about 90 days at a measuring interval of 10 minutes.
Maintenance and operation
Maintenance is tool-free, according to the maker, and a standard solution of 27 ml is consumed per calibration. Calibration intervals can be set from 1 hour to 90 days depending on the application and ambient conditions. Four sensor inputs allow extra Memosens measurement such as conductivity beside the hardness result.
CA80HA questions answered briefly
What does Endress+Hauser CA80HA measure? Total water hardness expressed as CaCO3 in mg/l, using phthalein purple read at 568 nm after MgEDTA replaces calcium with magnesium.
What range does CA80HA cover? 0 to 80 mg/l CaCO3, extendable with dilution factors of 5, 10 and 20 to 400, 800 and 1600 mg/l.
What is the repeatability of CA80HA? Plus or minus 0.3 mg/l, with an additional 1.5 percent of the end of range when dilution factor 5 is used.
How often does CA80HA measure? About every 7 minutes continuously, or adjustable from 10 minutes to 24 hours.
What does CA80HA do for RO and ion exchangers? It is intended to optimise reverse osmosis systems and ion exchangers and to guarantee process water quality in production plants.
Documents and quotation
The datasheet for CA80HA is attached to this page for checking every range, sample requirement and consumption figure before ordering. Send an RFQ with CA80HA, whether cooling or dilution is needed, supply voltage, fieldbus and quantity. It helps to know the expected hardness at the measuring point, since the base range stops at 80 mg/l CaCO3, and whether demineralised dilution water is available on the site. We can quote the reagent and standard solution with the analyzer, so that the first calibration can be performed immediately after installation, and we will confirm the cable entry configuration of four M16 and four M20 bores against your cabling before the analyzer is shipped.
Installation and Commissioning Planning
Planning ahead shortens downtime when a Endress+Hauser CA80HA goes into service. Confirm the available mounting space, cable entry or process connection, and the tools and spare seals needed on the day. Keep the existing configuration or calibration data so the new unit can be set up to match, and check that loop drawings and the asset register are updated after the swap. If the installation has to fit a short shutdown window, tell us the date when you request a quotation so that delivery of the Endress+Hauser (E & H) equipment can be planned around it.
Other Models in the Liquiline Ca80 Range
Seven Star LLC supplies models from the Liquiline Ca80 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser CA80FE Liquiline Dissolved Iron Analyzer | Liquid Analytical Systems | View details |
| Endress+Hauser CA80SI Liquiline Silica Analyzer for Boiler Water | Liquid Analytical Systems | View details |
| Endress+Hauser CA80HA Liquiline Water Hardness Analyzer | Liquid Analytical Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Endress+Hauser CA80HA Liquiline Water Hardness Analyzer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser CA80HA Liquiline Water Hardness
Answers from our engineering team on installation, compatibility and integration.
01What does Endress+Hauser CA80HA measure?
Total water hardness expressed as CaCO3 in mg/l, using phthalein purple read at 568 nm after MgEDTA replaces calcium with magnesium.
02What range does CA80HA cover?
0 to 80 mg/l CaCO3, extendable with dilution factors of 5, 10 and 20 to 400, 800 and 1600 mg/l.
03What is the repeatability of CA80HA?
Plus or minus 0.3 mg/l, with an additional 1.5 percent of the end of range when dilution factor 5 is used.
04How often does CA80HA measure?
About every 7 minutes continuously, or adjustable from 10 minutes to 24 hours.
05What does CA80HA do for RO and ion exchangers?
It is intended to optimise reverse osmosis systems and ion exchangers and to guarantee process water quality in production plants.