Brand:

Honeywell STF82F SmartLine Pseudo-Flange Level Transmitter

Description

STF82F: Honeywell pseudo-flange level transmitter

A pseudo flange is a compact flanged diaphragm that sits in the tank nozzle without the long extension of a conventional remote seal. Honeywell builds this concept into the STF82F, a plus and minus 400 inH2O (plus and minus 1000 mbar) level transmitter in the SmartLine STF800 family. Its mounting flange is 316L stainless steel and is wetted by the process, which is why this model is popular for aggressive cleaning agents, corrosive intermediates and any tank where carbon steel is not acceptable. It mounts to a 2 or 3 inch ANSI Class 150 flange.

Weight is modest for a flanged transmitter, 14 to 19 lb (6.4 to 8.7 kg) with the aluminium housing, and the accuracy is notable: 0.0375 percent of span standard, and 0.025 percent as an option, with a total performance figure of 0.087 percent of span at 80 inH2O.

Data sheet values for STF82F

Parameter Value
Range 400 inH2O to -400 inH2O (1000 to -1000 mbar)
Minimum span 4 inH2O (10 mbar)
Turndown Up to 100:1
Reference accuracy 0.0375 percent of span standard, 0.025 percent optional
Stability 0.01 percent of URL per year for 15 years
Flange 2 or 3 inch ANSI Class 150, 316L stainless steel, process wetted
Maximum allowable working pressure 230 psi (15.9 bar) at -29 to 38 degC; 185 psi (12.8 bar) at maximum meter body temperature
Process interface temperature rating No rating at 175 degC for the pseudo-flange types
Meter body temperature -40 to 110 degC rated; up to 125 degC operative
Ambient temperature -40 to 85 degC rated and operative
Weight 14 to 19 lb (6.4 to 8.7 kg), aluminium housing
Total performance example 0.087 percent of span at 80 inH2O

Choosing between the STF82F and the STF828

Both transmitters cover the same plus and minus 400 inH2O range. Choose the STF82F when the nozzle is a 2 or 3 inch Class 150 and the liquid is sensitive to dead pockets, because a pseudo flange has no extended diaphragm and no recess. The STF82F also benefits from a smaller temperature error. Choose the STF828 when you need a Class 300 or DN-standard connection, a 4-inch nozzle, or an extended diaphragm of 2, 4 or 6 inches through a thick insulated wall; the STF828 also tolerates higher process-interface temperature, with an operative limit of 175 degC.

Remember that the pseudo-flange rating drops to 185 psi (12.8 bar) at the maximum meter body temperature and that the datasheet gives no rating for these models at the 175 degC process-interface temperature, so keep hot services with the STF828 or consider another seal type.

Process conditions where STF82F performs well

Storage tanks holding caustic, brine, acids and cleaning chemicals in water-treatment and desalination plants; day tanks for glycol and corrosion inhibitor at oil and gas sites; and sanitary or semi-hygienic vessels in manufacturing are all candidates. In these environments the stainless mounting flange gives chemical resistance, and the lack of impulse tubing removes places where product can settle and solidify.

Wiring, protocols and display on the STF82F

The loop supply is 10.8 to 42.4 VDC with HART (0 to 1,440 ohms) or 15 to 49.3 VDC for Honeywell DE (0 to 1,200 ohms). Fieldbus units operate on 9.0 to 32.0 VDC. Wiring is polarity insensitive and accepts conductors up to 16 AWG. A standard LCD or advanced graphic display can be added or removed in the field, with 0, 90, 180 and 270 degree positioning, and an integral three-button option provides local zero, span and configuration.

Fitting, testing and servicing STF82F

Check that the nozzle face is flat and clean, because the face of the STF82F flange is a sealing surface and the diaphragm is flush with it. Tighten bolts evenly. After installation, trim zero with the tank empty or at a known level, then check span at a second point. For service, the electronics, display and meter body are modular: swap them in the field without changing the approvals, except in flameproof installations.

Pre-order checklist for STF82F

  • Nozzle: 2 or 3 inch ANSI Class 150 only; any other flange needs a different model.
  • Liquid: compatible with 316L stainless steel on the wetted flange and diaphragm material of your choice.
  • Span: at least 4 inH2O (10 mbar), and no more than 400 inH2O each side of zero.
  • Temperature: below the meter body limit of 125 degC and the 185 psi (12.8 bar) rating at that temperature.
  • Signal: HART 7, DE or FOUNDATION Fieldbus.
  • Safety: the family is documented for SIL 2/3 use, with a dual-seal design to ANSI/NFPA 70 and ISA 12.27.0.

Level transmitters of this class are commonly specified together with high-level switches that act independently of the analog loop; the transmitter provides the continuous measurement and the switch the safety trip. Because the STF800 family supports NAMUR NE-107 extended diagnostics on HART and Fieldbus, asset-management software can separate sensor faults from process issues. Finally, plan the spare strategy early: the electronics module, display and meter body are modular, so each can be replaced individually in the field, and a flanged level instrument is usually best stocked as a complete unit because its mounting flange is built to the nozzle.

Ordering the STF82F

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. To process an order for the STF82F we need the flange class and size, the housing and display choice, communication protocol and the fill fluid required (Silicone 200, CTFE, NEOBEE M-20 or Silicone 704).

Documents and quotation

Honeywell specification 34-ST-03-87 is attached as the datasheet for the STF82F. Please send an RFQ with the part number STF82F, quantity and delivery point in Oman or the GCC.

Typical Questions From Maintenance Teams

Maintenance engineers replacing a Honeywell STF82F usually ask whether the new unit is a direct fit, whether settings can be copied from the old one, and whether any accessories must be ordered separately. The answer depends on the exact order code and the generation of the installed pressure transmitters, so the nameplate details are the best starting point. Send them with your request and we will check the match, point out any differences in connections or options, and list the parts needed so that the job can be finished in one visit.

Other Models in the Honeywell Stf800 Range

Seven Star LLC supplies models from the Honeywell Stf800 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Honeywell STF832 SmartLine Flange-Mounted Level Transmitter, 100 psiPressure TransmittersView details
Honeywell STF82F SmartLine Pseudo-Flange Level TransmitterPressure TransmittersYou are viewing this model
Honeywell STF828 SmartLine Flange-Mounted Level TransmitterPressure TransmittersView details
Datasheets & Documents
  • PDF Datasheet Honeywell STF82F SmartLine Pseudo-Flange Level Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell STF82F SmartLine Pseudo-Flange Level

Answers from our engineering team on installation, compatibility and integration.

01What is special about the Honeywell STF82F design?
It is a pseudo-flange level transmitter: a 316L stainless steel flange that is itself process wetted, mounted on a 2 or 3 inch ANSI Class 150 nozzle without an extended diaphragm.
02What is the maximum working pressure of the STF82F?
The datasheet lists 230 psi (15.9 bar) at -29 to 38 degC and 185 psi (12.8 bar) at the maximum meter body temperature, with no rating at the process-interface limit.
03How accurate is the STF82F?
Reference accuracy is 0.0375 percent of span standard and 0.025 percent optional, with total performance of 0.087 percent of span at 80 inH2O.
04How much does the STF82F weigh?
The pseudo-flange models weigh 14 to 19 lb (6.4 to 8.7 kg) with an aluminium housing, lighter than the 18 to 32 lb of the true flange STF828.
05What range does the STF82F measure?
Plus and minus 400 inH2O (plus and minus 1000 mbar), with a minimum span of 4 inH2O (10 mbar) and up to 100:1 turndown.