Brand: Honeywell
Honeywell STD810 Differential Pressure Transmitter, 10 inH2O
Description
Honeywell STD810 overview
The Honeywell STD810 is a SmartLine ST 800 differential pressure transmitter built around a piezoresistive sensor. It is the lowest-range member of the ST 800 differential family, with a range of plus and minus 10 inH2O, intended for very small pressure differences. The SmartLine family is tested for compatibility with Experion PKS, which is why buyers who maintain Experion systems often ask for an exact model such as the Honeywell STD810 when replacing or extending a loop.
At this range the transmitter suits draft, ventilation and filter differential measurements where a few millibar matter, and the datasheet notes that this model includes only zero shift with static pressure. Seven Star LLC lists the STD810 for plants in Oman and the GCC that need the exact model number to match an existing instrument index, a spare parts list or a maintenance work order.
Key features of the STD810
- Piezoresistive sensing with on-chip static pressure and temperature compensation for high accuracy over a wide span of line pressures and ambient conditions.
- Communication options of 4 to 20 mA with Honeywell DE, HART version 7, or FOUNDATION Fieldbus, all with polarity-insensitive terminal connections.
- Response time of 90 ms for DE and HART analog output and 150 ms for FOUNDATION Fieldbus (host dependent).
- Standard alphanumeric LCD or advanced graphics LCD with up to eight screens, bar graph or trend formats, and a health watch indication.
- External zero, span and configuration through three optional buttons, plus a modular design that lets meter bodies, electronics and displays be replaced in the field.
- Plugged impulse line detection option, dual or triple calibration option for HART and Fieldbus units, and NAMUR NE-107 extended diagnostics for HART and Fieldbus.
- Integral dual seal design, listed compliance with SIL 2/3 requirements, and an optional additional 15-year warranty.
All of these features apply across the ST 800 differential pressure family, so the STD810 shares its electronics, display options and diagnostics with its neighbours. The model number mainly decides the measuring range, the stability figure and the maximum allowable working pressure.
STD810 technical specifications
The table below summarises the values published by Honeywell for the STD810. Where a value depends on the communication protocol, the housing or an ordering option, the entry says so, and the full model selection guide in the datasheet remains the reference for exact option codes.
| Parameter | Value |
|---|---|
| Model | STD810 |
| Measurement | Differential pressure, piezoresistive sensor |
| Upper range limit (URL) | 10 inH2O (24.90 mbar) |
| Lower range limit (LRL) | -10 inH2O (-24.90 mbar) |
| Minimum span | 0.1 inH2O (0.24 mbar) |
| Maximum turndown ratio | 100:1 |
| Stability | 0.15% of URL per year for 15 years |
| Reference accuracy, % of span | 0.035 |
| Response time | 90 ms (DE and HART analog output); 150 ms (FOUNDATION Fieldbus, host dependent) |
| Output and protocols | Two-wire 4 to 20 mA with DE or HART 7; FOUNDATION Fieldbus ITK 6.0.1 compliant |
| Supply voltage | HART: 10.8 to 42.4 VDC at terminals (intrinsically safe versions limited to 30 VDC); DE: 15 to 49.3 VDC; Fieldbus: 9.0 to 32.0 VDC |
| Maximum allowable working pressure | 50 psi (3.45 bar) |
| Rated ambient temperature | -40 to 85 °C (-40 to 185 °F) |
| Rated meter body temperature | -40 to 110 °C (-40 to 230 °F) |
| Fill fluid | Silicone Oil 200 or NEOBEE M-20 (the only two options for this model) |
| Process connection | 1/4 inch NPT, or 1/2 inch NPT with adapter |
| Housing | Low-copper aluminium, Type 4X, IP66 and IP67; all-stainless-steel housing optional |
| Net weight | 8.3 lb (3.8 kg) with aluminium housing |
| Failure mode current | Less than or equal to 3.6 mA or 21.0 mA and above (Honeywell standard or NAMUR NE 43) |
Honeywell gives a total performance example for this model: the STD810 at 2 inH2O reaches 0.505% of span under standard accuracy, 5 to 1 turndown, up to 50 °F of temperature variation and up to 1000 psi of static pressure. Total performance is calculated as the square root of the sum of squares of accuracy, temperature effect and static line pressure effect. Calibration verification is recommended by the manufacturer every four years. For differential pressure models, the static pressure limit equals the maximum allowable working pressure, and the overpressure rating is 1.5 times that value.
Typical applications in Oman and the GCC
A differential pressure transmitter turns the pressure drop across a primary element or a liquid column into a signal that a control system can use. The STD810 is typically specified for the following duties.
- Oil and gas: wellhead and separator monitoring, custody-adjacent flow measurement loops, compressor suction and discharge duties, and fuel gas skids.
- Utilities and power: boiler drum and feedwater measurements, steam header monitoring, condenser and cooling-water loops, and fuel supply lines.
- Water and wastewater: pump station discharge pressure, filter differential monitoring, desalination feed and reject lines, and pipeline surge surveillance.
- Manufacturing and process plants: utility headers, compressed air and steam distribution, chemical dosing skids, and packaged equipment where a smart HART or fieldbus device is specified.
Low-range work such as furnace draft, air handling and clean filter monitoring is where this model is normally considered. Oman and Gulf plants also add dust, heat and coastal humidity to the specification. The STD810 housing is listed as Type 4X, IP66 and IP67 with a silicone cover o-ring, and the ambient rating runs from -40 to 85 °C, which covers outdoor installations in the region when the sunshade and mounting practice are correct.
Selection and compatibility notes for the STD810
Begin with the measuring range. The STD810 has an upper range limit of 10 inH2O (24.90 mbar), and the zero and span can be set anywhere inside the range limits. If your calibrated span sits at the bottom of the range, check the accuracy and temperature effect figures for the turndown you plan to use, because the datasheet shows how accuracy changes with turndown.
Next choose the protocol. Honeywell lists DE, HART 7 and FOUNDATION Fieldbus for the ST 800 family. DE units suit existing Honeywell DE loops, HART suits most modern analog loops and asset management software, and Fieldbus suits segments that already run FOUNDATION Fieldbus. State the protocol in the RFQ so the correct electronics module is quoted for the STD810.
Materials need care. The datasheet lists barrier diaphragm choices of 316L stainless steel, Hastelloy C-276, Monel 400, tantalum and gold-plated versions, with process heads in carbon steel, 316 stainless steel, Hastelloy C-276 or Monel 400. Carbon steel heads are zinc plated and Honeywell advises against them for water service, so choose 316 stainless steel heads for water and wastewater work. For this model Honeywell lists only Silicone Oil 200 and NEOBEE M-20 fill fluid, and the MAWP is 50 psi (3.45 bar), so do not use it on lines that could see higher static pressure.
If you are replacing an older transmitter, give us the old nameplate model number, the calibrated range, the process connection and the approval marking. We then match these against the STD810 option list instead of guessing.
Installation and commissioning
Mount the STD810 with the supplied bracket on a 2 inch vertical or horizontal pipe, or in another convenient position, since the transmitter can be mounted in virtually any orientation. Keep impulse lines short, sloped and free of trapped gas or liquid so the reading reflects the process and not the tubing. A three-valve or five-valve manifold makes zeroing safer.
Wire the loop with up to 16 AWG conductors. The terminal connection is polarity insensitive, which removes one common commissioning mistake. Check that the supply voltage at the terminals stays inside the range for the chosen protocol, remembering the load resistance limit for HART and DE loops.
During commissioning, confirm the zero with both sides of the STD810 equalised, set the lower and upper range values, review the damping, and perform a loop test. If the optional display and buttons are fitted, the basic range, engineering unit, loop test, loop calibration, zero and span functions can be done locally. Record the final configuration and the write-protect status for the handover file.
Maintenance and diagnostics
The STD810 reports critical and non-critical diagnostics. Critical items include electronics module faults, meter body memory or configuration data corruption and sensor communication timeout, and they appear on the integral display. Non-critical items include display failure, electronics communication failure and sensor over-temperature. Reading them through the DD, DTM or FDI tools helps maintenance teams plan work before a trip occurs.
Because the design is modular, a meter body, an electronics module or a display can be replaced without redoing the whole calibration, and field replacement is permitted in all electrical environments except flameproof without affecting the approval. Keep one spare electronics module for each protocol in use and note the STD810 meter body serial number on the spare parts list.
Typical routine work is a periodic zero check, a visual check of the housing seals and cable glands, inspection of impulse lines for plugging, and a documented calibration verification at the interval your site procedure requires.
Related products and ordering notes
Buyers of the STD810 often also need a manifold, mounting bracket, flange adapters or a matching gauge pressure transmitter such as the Honeywell STG830, STG840 or STG870 when a loop mixes differential and static measurements. Other models in the same differential family are the STD810, STD815, STD820, STD830 and STD870, which differ mainly in range.
For temperature points in the same plant area, Honeywell also offers the STT850 SmartLine temperature transmitter and the STT3000 series. Tell us the complete list when you send your RFQ and we will quote the group together. The part number to quote is STD810.
Frequently asked questions in brief
The questions below cover range, working pressure, fill fluid and protocols for the STD810, and each answer follows the Honeywell specification.
Documents and quotation
A Honeywell datasheet for the STD810 is attached to this page so your engineers can check ranges, materials and approvals before ordering. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. To request a quotation, send an RFQ that states the part number STD810, the quantity, the measuring range or sensor type, the communication protocol and any display or approval requirement. We will confirm availability and lead time and reply with a written quotation.
Other Models in the Honeywell Std800 Range
Seven Star LLC supplies models from the Honeywell Std800 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell STD810 Differential Pressure Transmitter, 10 inH2O | Pressure Transmitters | You are viewing this model |
| Honeywell STD815 Differential Pressure Transmitter, 100 inH2O | Pressure Transmitters | View details |
| Honeywell STD820 Differential Pressure Transmitter, 400 inH2O | Pressure Transmitters | View details |
Datasheets & Documents
- Datasheet Honeywell STD810 Differential Pressure Transmitter, 10 inH2O Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell STD810 Differential Pressure Transmitter,
Answers from our engineering team on installation, compatibility and integration.
01What is the measuring range of the STD810?
The STD810 has an upper range limit of 10 inH2O (24.90 mbar) and a lower range limit of -10 inH2O (-24.90 mbar), with a minimum span of 0.1 inH2O (0.24 mbar).
02What is the maximum allowable working pressure of the STD810?
The datasheet gives 50 psi (3.45 bar) for the STD810, which is far lower than the higher-range ST 800 models.
03Which fill fluids can the STD810 use?
Honeywell lists only Silicone Oil 200 and NEOBEE M-20 for the STD810, so other fluids are not available on this model.
04Which communication protocols are available?
The ST 800 family offers 4 to 20 mA with Honeywell DE, HART version 7, and FOUNDATION Fieldbus, all with polarity-insensitive wiring.
05How do I order the STD810 from Seven Star LLC?
Send an RFQ with the part number STD810, quantity, protocol, display option, materials and approval needs. We reply with availability and a quotation.