- Automation & ControlView all 2,895 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Yokogawa
Yokogawa YS1500 Indicating Controller
Description
Yokogawa YS1500 overview: indicating controller for PID, cascade and selector control
The Yokogawa YS1500 is an indicating controller with the fundamental functions needed for PID control. Functions can be selected to suit the application, including input signal processing such as square root extraction and linear segment conversion, feed-forward calculation, and single-loop, cascade or selector mode.
Standard models of the Yokogawa YS1500 are smaller and lighter than earlier series and comply with international safety standards including CE Mark and optional FM and CSA nonincendive approvals. Compatible types keep the panel cutout and depth of earlier Yokogawa controllers.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list YS1500 so that maintenance, instrumentation and procurement teams can quote the exact model code that appears in the manufacturer documentation.
Key features of YS1500
- Full-dot TFT LCD for meter, trend, bar graph, alarm and event displays.
- Function selection mode: single-loop, cascade or selector control chosen by parameters, without programming.
- Dual CPU for display and control, with an independent hard manual circuit (not with the -2xx suffix option).
- Non-volatile memory for backup, so no battery or capacitor maintenance.
- AC and DC dual power supply with wide operating voltage.
- Basic type with 250 mm depth and an IP54 dust and splash-proof faceplate.
- Optional Ethernet (Modbus/TCP, basic type), RS485 and DCS-LCS communication.
YS1500 technical specifications
The table below lists values published by the manufacturer for the product family of YS1500. Where a value depends on the ordered configuration, the model and suffix code table in the General Specifications governs.
| Parameter | Value |
|---|---|
| Model | YS1500 indicating controller (suffix codes select the type) |
| Basic type | YS1500-x0x: 4 analog inputs (1 to 5 V), 2 analog outputs (1 to 5 V), 1 output (4 to 20 mA), 6 digital I/O |
| Compatible types | YS100, YS80 internal unit, EBS and I series, EK and HOMAC, 100 line compatible types |
| Control modes | Single-loop, cascade, selector |
| Display | Full-dot TFT LCD |
| Hard manual circuit | Independent analog circuit (not incorporated with -2xx suffix option) |
| Memory backup | Non-volatile; no battery or capacitor |
| Faceplate | IP54 dust and splash-proof (basic type) |
| Depth | 250 mm (basic type) |
Typical applications of YS1500 in Oman and the GCC
- PID control of temperature, flow, level and pressure loops on utility systems.
- Cascade control on boiler drum level and heater outlet temperature.
- Selector control on override and protection schemes.
- Replacement of older YS100 and YS80 controllers in existing panels.
- Local backup control stations in desalination and power plants.
Panel-mounted single-loop controllers and indicators remain in service for decades in power stations, refineries, desalination plants and process units across Oman and the GCC, often as the last manual-station layer behind a DCS or as stand-alone control on boilers, heaters, dosing and utility loops. Plant owners therefore search for the exact model code, such as YS1500, so that a failed unit can be replaced with one that fits the existing panel cutout and wiring.
Selection and compatibility notes for YS1500
The YS1500 works through selectable functions, while the YS1700 adds a user program. If your application needs custom calculations, ask about the YS1700; for standard PID, cascade and selector control the YS1500 is the simpler choice.
Read the full model and suffix code from the nameplate of the unit being replaced to confirm the type, power supply and options.
The model code of YS1500 is only the beginning, because the suffix codes select the type (basic, expandable I/O, or one of the compatible types for older Yokogawa lines), the power supply, the communication option and optional functions. Send us the full code from the nameplate of the unit being replaced, or the specification you want, and we will compare it with the model and suffix code table in the manufacturer General Specifications before quoting.
Installation and commissioning
Check the panel cutout and depth, wire according to the manufacturer terminal diagram, confirm the supply type on the nameplate and set function selection mode, ranges and alarms from the front panel. Test manual, auto and cascade transfers before releasing the loop.
Check the panel cutout and depth against the type you ordered, wire the input, output and power terminals according to the manufacturer terminal diagram, and verify the power supply type on the nameplate before energising. After power-up, set the input ranges, alarms and control parameters from the engineering displays, then run a manual-to-automatic changeover test with the process in a safe state.
Maintenance, calibration and service
Verify the 1 to 5 V inputs and the output against a calibrator and keep a written copy of the PID parameters and function settings.
Controllers of this class use non-volatile memory and need no battery replacement, so routine care is mostly inspection of terminals, cleaning of the front panel and periodic verification of input and output accuracy against a calibrator. Record the tuning parameters and any user program, and keep a spare configuration file so that a replacement can be commissioned quickly.
Related products and ordering notes for YS1500
- YS1700 programmable indicating controller and YS1310 indicator with alarms.
- YS110 standby manual station and setting software.
When you request YS1500, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. We can also check related codes so that a single RFQ covers the instrument and the parts that go with it.
Frequently asked questions about YS1500
- What is YS1500? YS1500 is an indicating controller for PID, cascade and selector control with functions selected by parameter.
- How many inputs does YS1500 have? The basic type has four 1 to 5 V analog inputs, two 1 to 5 V analog outputs, one 4 to 20 mA output and six digital points that can be DI or DO.
- Can YS1500 replace older controllers? The manufacturer offers compatible types for YS100, YS80, EBS and I series, EK and HOMAC, so check the existing code.
- Does YS1500 need a backup battery? No. The manufacturer states that non-volatile memory is used and no battery or capacitor is used for memory backup.
- How do I order YS1500? Send Seven Star LLC the full model and suffix code, quantity and delivery location and we will quote in writing.
Documents and quotation
The manufacturer General Specifications for the family of YS1500 is available and we can send it with your quotation. To request pricing and lead time, send an RFQ to Seven Star LLC with the part number YS1500, the quantity, the full model and suffix code or the nameplate details of the unit being replaced, the delivery location and any certificate requirements. We will confirm availability and reply in writing with a quotation for YS1500.
Datasheets & Documents
- Datasheet Yokogawa YS1500 Indicating Controller Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa YS1500 Indicating Controller
Answers from our engineering team on installation, compatibility and integration.
01What is YS1500?
YS1500 is an indicating controller for PID, cascade and selector control with functions selected by parameter.
02How many inputs does YS1500 have?
The basic type has four 1 to 5 V analog inputs, two 1 to 5 V analog outputs, one 4 to 20 mA output and six digital points that can be DI or DO.
03Can YS1500 replace older controllers?
The manufacturer offers compatible types for YS100, YS80, EBS and I series, EK and HOMAC, so check the existing code.
04Does YS1500 need a backup battery?
No. The manufacturer states that non-volatile memory is used and no battery or capacitor is used for memory backup.
05How do I order YS1500?
Send Seven Star LLC the full model and suffix code, quantity and delivery location and we will quote in writing.


















Reviews