Schneider Electric A9N26476 Acti9 MX shunt trip release

Description

A9N26476: Acti9 MX shunt trip release, 110–415 V AC / 110–130 V DC

The A9N26476 is a Schneider Electric Acti9 MX shunt trip release, an 18 mm side-mounted module that trips a compatible Acti9 breaker remotely when its coil is energised. Its control voltage is 110–415 V AC 50/60 Hz and 110–130 V DC. Seven Star LLC supplies the A9N26476 in Oman and the GCC as an independent supplier based in Muscat.

This unit is an accessory, not a breaker: it only works when mounted on a compatible Acti9 device, and it makes remote opening possible for emergency stop circuits, fire-alarm shutdown, process interlocks and monitored feeders. This version has no auxiliary contact, so the breaker position must be reported by a separate accessory if it is needed.

Technical specifications of the A9N26476

Parameter Specification
Manufacturer / part number Schneider Electric / A9N26476
Range / product Acti9 MX
Type Shunt trip release
Control circuit voltage [Uc] 110–415 V AC 50/60 Hz and 110–130 V DC
Mounting Fixed, 35 mm symmetrical DIN rail
Width 18 mm (2 modules of 9 mm)
Dimensions (H × W × D) 82.5 × 18 × 73.5 mm
Net weight 60 g
Colour White
Local signalling Action indicator
Comb busbar compatibility Top: yes
Terminals Screw clamp terminal (bottom) – 2 cable(s) 1.5 mm² – flexible; Screw clamp terminal (bottom) – 2 cable(s) 1.5 mm² – flexible with ferrule; Screw clamp terminal (bottom) – 1 cable(s) 0.5–2.5 mm² – rigid
Stripping length / torque 9 mm / 1 N.m (bottom)
Standard EN/IEC 60947-2
Tropicalisation Class 2
Humidity 95 % at 55 °C
Operating temperature -25–50 °C
Storage temperature -40–85 °C
Approvals listed KEMA ASEFA LCIE ASTA

Wiring, testing and maintenance of the A9N26476

Connect the control wires to the bottom terminals: the datasheet lists one rigid conductor of 0.5–2.5 mm², or two flexible 1.5 mm² conductors with or without ferrules, with 9 mm stripping and 1 N.m torque. Make sure the supply type matches the coil: an AC coil must not be driven from a DC rail, and the polarity convention of DC control circuits should be checked against the wiring diagram supplied with the product.

After commissioning, test the trip by applying the control voltage once and confirming that the breaker opens and the indicator shows; repeat at each annual maintenance round. A shunt trip that never operates gives no feedback until it is needed, so a periodic test is the only way to know it works. Keep the coil circuit fuse or breaker rated per the manufacturer’s data.

Where the A9N26476 is used in Oman and the GCC

Shunt trips are used in emergency stop and fire-alarm shutdown schemes of buildings and industrial plants, for remote isolation of feeders to pumps and chillers, and for load shedding on generator-backed boards. The plain MX version is the lower-cost choice where only a remote trip is needed. The temperature range of -25–50 °C suits indoor panels; on rooftop or plant-room boards in the Gulf the heat near the top of an enclosure can exceed that range, so mount the module away from heat sources.

MX references to compare with the A9N26476

Related references in the same accessory family:

Part number Version Control voltage Signal contact
A9N26946 MX + OF 110–415 V AC 50/60 Hz and 110–130 V DC 1 C/O
A9N26948 MX + OF 12–24 V AC 50/60 Hz and 12–24 V DC 1 C/O

Breaker compatibility of the A9N26476

The datasheet lists these Acti9 ranges as compatible: iDPN, C120, C40, C60H-DC, C60NA-DC, C60PV-DC, DPN Vigi, DT40, DT60, ID C40, IDc, ITG40, ID, SW60-DC. The C120 range is among them, which includes the A9N18346 and similar C120 breakers, but always check the exact breaker reference and its mounting side before you order. The module is fixed-mounted, takes the comb busbar at the top and mounts on the side of the breaker so that the pair occupies the breaker width plus 18 mm of rail.

Compatibility lists in a datasheet name the breaker families, not every pole count or rating, so confirm with the breaker datasheet that the shunt trip can be added on the chosen frame.

Selection checklist and RFQ details for the A9N26476

Check these before ordering.

  • Control voltage: 110–415 V AC 50/60 Hz and 110–130 V DC must match the signal supply.
  • Auxiliary contact: not needed.
  • Breaker: the exact reference must be listed as compatible.
  • Mounting: one 18 mm slot to the side of the breaker.
  • Signal source: relay, PLC output, push button or fire panel.

With your enquiry, send:

  • Part number A9N26476 and quantity.
  • The breaker reference it will be fitted to.
  • Control supply type and voltage.
  • Delivery location and date.

What the A9N26476 does inside a breaker assembly

A shunt trip is a coil that sits beside a circuit breaker and, when energised by a command signal, releases the breaker mechanism. It does not protect the circuit by itself and it does not close the breaker again; the breaker handle must be reset manually afterwards. For this unit the coil is specified for 110–415 V AC 50/60 Hz and 110–130 V DC, so it follows the supply of the control circuit that triggers it. The wide 110–415 V AC and 110–130 V DC range lets the same coil be used on 230 V, 400 V and 110 V DC control supplies, which simplifies stock keeping.

With no signal contact, the module is the simplest option for a pure remote trip.

Documents and quotation

The manufacturer’s product datasheet for the A9N26476 is attached on this page for reference; it is the document to use when you verify ratings, dimensions and approvals against your own design. It lists the control voltage and compatibility for this exact reference.

To receive a quotation, send the part number A9N26476 with quantity and delivery location in Oman or the GCC. Seven Star LLC replies with availability and lead time as an independent supplier based in Muscat.

Datasheets & Documents
  • PDF Datasheet Schneider Electric A9N26476 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric A9N26476 Acti9 MX shunt trip

Answers from our engineering team on installation, compatibility and integration.

01What does the A9N26476 do?
It is a shunt trip release: when its coil is energised with 110-415 V AC 50/60 Hz and 110-130 V DC it opens a compatible Acti9 breaker remotely. The breaker must be reset by hand.
02What control voltage does the A9N26476 need?
The datasheet lists 110-415 V AC 50/60 Hz and 110-130 V DC control circuit voltage for this reference.
03Does the A9N26476 have an auxiliary contact?
No, it is the shunt trip without an auxiliary contact.
04Which breakers can the A9N26476 be fitted to?
The datasheet lists Acti9 iDPN, C120, C40, C60H-DC, C60NA-DC, C60PV-DC, DPN Vigi, DT40, DT60, ID C40, IDc, ITG40 and ID ranges. Confirm the exact breaker reference.
05How wide is the A9N26476?
It is 18 mm wide (2 modules of 9 mm), 82.5 mm high and 73.5 mm deep, mounted on a 35 mm DIN rail.