Brand:

Honeywell UDI1700 1/8 DIN Universal Digital Indicator

Description

Honeywell UDI1700 1/8 DIN universal digital indicator overview

The Honeywell UDI1700 is a 1/8 DIN horizontal panel indicator that reads a process variable from a universal input and displays it on a large red four-digit LED. It is the companion of the UDC1200 and UDC1700 controllers, sharing their technology, and it is aimed at applications that need accurate indication and alarm contacts rather than control. The manufacturer states it is downward compatible with existing UDI1500 applications and wiring.

Up to five soft alarms are available, each with an optional relay, and alarm 1 can be latched so that an operator must acknowledge it. The display is dual colour, red and green, and a dedicated digit shows degrees C or F. The unit also stores the minimum and maximum values reached by the process variable since the last reset and the time elapsed since alarm 1 became active.

This page summarises the manufacturer documentation for the Honeywell UDI1700 for buyers in Oman and the GCC. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Key features of the UDI1700

The following features come from the manufacturer specification for the UDI1700.

  • One universal input with 0.1 percent accuracy, accepting thermocouples, RTDs and linear DC signals configured from the front.
  • Large 14 mm four-digit red LED display with a dual colour red and green capability and a dedicated digit for temperature units.
  • Up to five soft alarms with up to five SPDT alarm relays, PV high or low action, direct or reverse acting, with logical OR or AND combinations.
  • Minimum and maximum indication of the process variable, and elapsed time since alarm 1 became active.
  • Plug-in option boards for alarm relay output, dual alarm relay and linear output for PV retransmission, which are detected automatically.
  • Optional 24 V dc transmitter power supply on output 3, one digital input and RS485 Modbus communication.
  • Universal 90 to 264 V ac supply with a 24/48 V ac/dc option, and NEMA 3 front face protection.
  • Jumper-free configuration from the front panel and easy field upgrade.

UDI1700 technical specifications

The table lists the main data for the UDI1700 from the manufacturer specification sheet.

Parameter Value
Model UDI1700
Format 1/8 DIN horizontal
Dimensions 96 mm wide, 48 mm high, 100 mm deep
Weight 210 g maximum
Display Four-digit red LED, 14 mm, with dual colour capability
Accuracy 0.1 percent of span plus or minus 1 LSD
Sampling rate Four samples per second
Digital filter Off, or 0.5 to 100.0 seconds
Input isolation 2500 V from outputs and supply
Alarms Up to five soft alarms, five SPDT relays
Alarm relay rating 2 A at 120 or 240 V, resistive, over 500,000 operations
Linear DC output PV retransmission, accuracy 0.25 percent
Communication RS485 Modbus
Power supply 100 to 240 V ac, 20 to 48 V ac or 22 to 65 V dc
Power consumption 7.5 VA ac, 5 W dc
Approvals UL and CE
Front panel NEMA 3

Typical applications in Oman and the GCC

The UDI1700 is used where an operator needs to see a measurement clearly and where alarm contacts are needed without a control loop. Typical uses in Oman and the GCC include the following.

  • Oil and gas: temperature and pressure indication with high and low alarm contacts on skid and package panels.
  • Utilities and power: bearing, winding and oil temperature display with alarm relays to a control room.
  • Water and wastewater: level or pressure indication on pumping stations, with retransmission to a PLC.
  • Manufacturing: process temperature display beside UDC1200 and UDC1700 controllers on machine panels.

Selection and compatibility notes for the UDI1700

Choose the UDI1700 when you need an indicator with alarms rather than a controller. It is the same size as the UDC1700, so a mixed row of controllers and indicators has a uniform look. If you need to control the process, select the UDC1700 instead.

Choose the alarm relay modules, linear output and transmitter supply when ordering, because these are plug-in option boards. Alarm 1 can be latched to require acknowledgment, and the minimum and maximum feature can be used for process reports. Specify the supply voltage you need among the ac and dc ranges.

Installation and commissioning of the UDI1700

Install the UDI1700 following the manufacturer manual.

  • Cut the panel for a 1/8 DIN horizontal opening and allow 100 mm depth behind the panel.
  • Wire the rear screw terminals, checking the option boards fitted and the supply voltage.
  • Keep sensor cabling away from power wiring and use shielded cable for RS485.
  • Configure input type, range, alarms and any retransmission from the front panel.

Maintenance and service life

The UDI1700 needs very little maintenance. Keep the front clean, tighten terminals during shutdowns and verify the input accuracy at your usual calibration interval. Reset the minimum and maximum values after calibration or when a new reporting period starts.

Related products and ordering notes

Related Honeywell instruments available on request include the UDC1700, UDC1200 and DC1040. Send the model code with the option boards you need so Seven Star LLC can quote the correct unit.

UDI1700 questions in brief

Typical questions about the UDI1700 concern alarms, display and communication. It is a 1/8 DIN indicator with universal input, up to five alarm relays and optional Modbus. The answers below summarise the key facts.

Documents and quotation

The manufacturer datasheet for the UDI1700 is available from Seven Star LLC with this listing when it is attached, and it should be read together with the installation manual before any engineering decision. To request a quotation, send an RFQ that states the part number UDI1700, the quantity, the delivery location and, where relevant, the options you need. Seven Star LLC replies with availability and lead time; no price is published on this page.

Datasheets & Documents
  • PDF Datasheet Honeywell UDI1700 1/8 DIN Universal Digital Indicator Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell UDI1700 1/8 DIN Universal Digital

Answers from our engineering team on installation, compatibility and integration.

01Is the UDI1700 a controller or an indicator?
It is an indicator. It displays a process variable and drives alarm contacts but has no control output.
02How many alarms does the UDI1700 have?
It offers up to five soft alarms with up to five SPDT relay outputs, and alarm 1 can be latched until acknowledged.
03Does the UDI1700 offer retransmission?
Yes. An optional linear DC output on output 2 can retransmit the process variable.
04What size is the UDI1700?
It is a 1/8 DIN horizontal unit, 96 mm wide, 48 mm high and 100 mm deep, with a 14 mm display.
05How can I request a quotation for the UDI1700?
Send an RFQ with the full model code, quantity and delivery location. Seven Star LLC will reply with availability and lead time; this page shows no price.