Honeywell UDC1200 1/16 DIN Universal Digital Controller
Description
Honeywell UDC1200 1/16 DIN universal digital controller overview
The Honeywell UDC1200 is a compact 1/16 DIN microprocessor controller, only 48 x 48 mm on the front, intended for temperature, pressure and level loops on machines and small process plant. It belongs to the Micro-Pro series and shares a specification sheet with the 1/8 DIN UDC1700. The manufacturer describes it as downward compatible with existing UDC1000 and UDC1500 applications and installations.
Every input type is available on every unit and is chosen from the menu: a wide range of thermocouple types, RTD, and linear current or voltage signals. A dual four-digit LED display shows the process variable above and the setpoint below, and a four-digit security code prevents unwanted changes. The option boards are jumper-free and detected automatically, so a unit can be upgraded in the field.
This page summarises the manufacturer documentation for the Honeywell UDC1200 for buyers in Oman and the GCC. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Key features of the UDC1200
The following features come from the manufacturer specification for the UDC1200 and UDC1700 series.
- Universal input with typical accuracy of 0.1 percent of span plus or minus one least significant digit, sampled four times per second.
- Up to three outputs chosen from relay, SSR driver or DC linear types, with time proportional, current proportional, duplex and three position step algorithms.
- Pre-tune and self-tune strategy that sets PID values close to the optimum and then refines them.
- Two soft alarms plus a loop alarm that watches the process response to detect a fault in the control loop, without needing a heater breaker circuit.
- Dual display with selectable lower line: setpoint read only, setpoint adjustable, ramping setpoint or blank.
- A limit controller version provides a latched relay for safety shut-off, with high or low limit action and manual reset.
- Optional RS485 communication using ASCII or Modbus RTU at up to 19200 baud, for up to 32 units on one link.
- Universal 90 to 264 V ac supply, with a 24/48 V ac/dc option, and a NEMA 3 front face.
UDC1200 technical specifications
The table lists the main specification of the UDC1200 taken from the combined UDC1200 and UDC1700 sheet.
| Parameter | Value |
|---|---|
| Model | UDC1200 |
| Format | 1/16 DIN, 48 x 48 mm front |
| Panel cutout | 45 mm x 45 mm |
| Case depth | 110 mm |
| Weight | 210 g maximum |
| Accuracy | 0.1 percent of span plus or minus 1 LSD |
| Sampling rate | Four samples per second |
| Digital filter | Off, or 0.5 to 100.0 seconds |
| Input isolation | 2500 V from outputs (except SSR) and supply |
| Thermocouple types | R, S, J, T, K, L, B, C, N |
| RTD | Pt100 (IEC), 3-wire |
| DC linear | 10-50 mV, 0-50 mV, 4-20 mA, 0-20 mA, 1-5 V, 0-5 V, 2-10 V, 0-10 V |
| Relay output | SPDT, 2 A at 120 or 240 V resistive |
| DC linear output | 0-20 mA, 4-20 mA, 0-5 V or 0-10 V |
| Alarms | Two soft alarms plus loop alarm |
| Communication | RS485 ASCII or Modbus RTU, up to 19200 baud |
| Power supply | 90 to 264 V ac, 50/60 Hz; 24/48 V ac/dc optional |
| Power consumption | 4 W |
| Operating temperature | 0 to 55 degC |
| Approvals | UL recognized; FM approval on the limit model; CE design |
Typical applications in Oman and the GCC
The UDC1200 fits wherever panel space is short and a single PID loop is enough. Typical uses in Oman and the GCC include the following.
- Oil and gas: heat tracing panels, sample system heaters and small skid enclosures where a compact controller is mounted beside other 1/16 DIN devices.
- Utilities and power: oil tank heaters, small boiler and calorifier loops, and limit controllers that provide over-temperature protection.
- Water and wastewater: laboratory and treatment skid heaters, plus dosing pump or valve control from a 4-20 mA output.
- Manufacturing: packaging machines, plastics extruders, ovens, environmental chambers and food processing equipment.
Selection and compatibility notes for the UDC1200
Choose the UDC1200 when a 1/16 DIN cutout is all that is available. If you need a larger display and more room for terminals, the UDC1700 offers the same functions in the 1/8 DIN size, including a remote setpoint model. If you need ramp and soak profiles, look at the DCP50 programmer in the same 1/16 DIN size.
Select the output type for each of the three outputs from the model selection guide. A relay suits contactors and heaters, an SSR driver suits solid state relays, and the DC linear output suits valves or SCR units and can also retransmit the process value or setpoint. Decide in advance whether the digital input, RS485 option or 24/48 V supply is needed, because these are set by the model code.
Installation and commissioning of the UDC1200
Install the UDC1200 using the pre-assembled mounting fixture supplied with the unit.
- Cut the panel to 45 mm x 45 mm and allow at least 110 mm behind the panel for the case.
- Slide the controller in from the front and secure it with the mounting fixture.
- Wire the inputs and outputs to the rear screw terminals, keeping sensor cables apart from power wiring.
- Configure the input type, range, alarm and outputs, then run pre-tune before starting self-tune.
Maintenance and service life
The UDC1200 uses non-volatile EEPROM memory, which the manufacturer states retains data for more than 100 years, so configuration survives a power loss. Wipe the front face clean, check terminals for tightness during shutdowns, and verify input accuracy on your normal calibration cycle.
Related products and ordering notes
Related Honeywell controllers available on request include the UDC1700, DCP50 and UDI1700 indicator. Please send the full model code so Seven Star LLC can quote the exact output and option combination.
UDC1200 questions in brief
Typical questions about the UDC1200 cover size, inputs and communication. It is a 1/16 DIN controller with universal input, up to three outputs and optional RS485. The answers below summarise the main points.
Documents and quotation
The manufacturer datasheet for the UDC1200 is available from Seven Star LLC with this listing when it is attached, and it should be read together with the installation manual before any engineering decision. To request a quotation, send an RFQ that states the part number UDC1200, the quantity, the delivery location and, where relevant, the options you need. Seven Star LLC replies with availability and lead time; no price is published on this page.
Other Models in the UDC Range
Seven Star LLC supplies models from the UDC range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell UDC2500 1/4 DIN Universal Digital Controller | Controllers & Data Acquisition | View details |
| Honeywell UDC3200 1/4 DIN Controller with Math Functions | Controllers & Data Acquisition | View details |
| Honeywell UDC3500 1/4 DIN Dual-Loop Digital Controller | Controllers & Data Acquisition | View details |
| Honeywell UDC1200 1/16 DIN Universal Digital Controller | Controllers & Data Acquisition | You are viewing this model |
Datasheets & Documents
- Datasheet Honeywell UDC1200 1/16 DIN Universal Digital Controller Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell UDC1200 1/16 DIN Universal Digital
Answers from our engineering team on installation, compatibility and integration.
01What size is the UDC1200?
It is a 1/16 DIN controller with a 48 x 48 mm front, a 45 mm x 45 mm panel cutout and a case depth of 110 mm.
02What inputs can the UDC1200 accept?
It accepts thermocouple types R, S, J, T, K, L, B, C and N, Pt100 RTD, and DC linear signals such as 4-20 mA, 0-5 V and 0-10 V, chosen from the menu.
03Does the UDC1200 offer communication?
Yes. An optional RS485 interface supports ASCII or Modbus RTU at up to 19200 baud, with up to 32 units on one link.
04Is there a limit controller version of the UDC1200?
Yes. The 1/16 DIN limit model has a latched relay output for high or low limit shut-off that needs manual reset.
05How can I request a quotation for the UDC1200?
Send an RFQ with the full model code, quantity and delivery location. Seven Star LLC will reply with availability and lead time; this page shows no price.