Brand: Phoenix Contact
Phoenix Contact UT 6 Feed-Through Terminal Block, 41 A
Description
UT 6: 41 A feed-through block for 6 mm² power circuits
The UT 6 steps up from the UT 4 to carry 41 A at 1000 V, with a nominal cross section of 6 mm² and a clamp range of 0.2 to 10 mm². It keeps the same slim UT profile, so a row can mix signal blocks and power blocks without changing the rail layout.
The type code is simple: UT stands for universal terminal and 6 for the 6 mm² nominal cross section. Order number 3044131 is the gray version. Seven Star LLC supplies the UT 6 in Oman and the GCC as an independent supplier in Muscat.
Technical specifications of the UT 6
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Phoenix Contact UT 6 (order no. 3044131) |
| Type | Feed-through terminal block, screw connection, 2 connections |
| Rated voltage / current | 1000 V / 41 A (maximum load current 57 A with 10 mm²) |
| Nominal cross section | 6 mm² |
| Conductor range | 0.2 to 10 mm², rigid and flexible |
| Flexible with ferrule | 0.2 to 4 mm² in the listed ferrule data; check the datasheet for larger sleeves |
| Screw thread / torque | M4 / 1.5 to 1.8 Nm |
| Rated surge voltage | 8 kV |
| Power dissipation at nominal condition | 1.31 W |
| Bridging voltage | 1000 V adjacent bridging; 500 V for non-adjacent bridging |
| Standard | IEC 60947-7-1 |
| Mounting | NS 35/7.5 and NS 35/15 rails; colour gray |
Why the UT 6 uses an M4 clamp screw
The M4 screw and larger clamp body let the UT 6 hold thicker conductors firmly. Tightening to 1.5 to 1.8 Nm presses the strands against the current bar; the higher torque compared with the UT 4 matches the bigger wire. Power dissipation at nominal condition is 1.31 W per block, which is the number to use for heat calculation in a row of fully loaded circuits.
The data sheet also gives different voltages for bridging: 1000 V for adjacent blocks bridged with a bridge, and 500 V where bridging is made between non-adjacent blocks. This matters when you plan a common supply across a mixed row.
Where the UT 6 fits in a terminal row
Use the UT 6 for motor feeders, heater circuits, power supply outputs and distribution of 24 V DC where currents of 20 to 40 A are expected. It is also a good intermediate size in rows where the incoming cable is 10 mm² and the equipment side is 6 mm², because the clamp accepts the larger wire.
Neighbouring sizes are the UT 4 for 4 mm² and the UT 10 for 10 mm² wire. The protective earth block of this size is the UT 6-PE, which has the same footprint.
Selection and ordering checklist for the UT 6
- Nominal current of the circuit below 41 A with derating.
- Conductor size: 6 mm² nominal, up to 10 mm².
- Bridge type and bridging voltage for adjacent or non-adjacent bridging.
- Rail type NS 35/7.5 or NS 35/15.
- Need for end covers, partition plates and labels.
- Packing unit quantity.
Installation, commissioning and maintenance of the UT 6
Use a screwdriver that fits the clamp screw squarely and tighten to 1.5 to 1.8 Nm. For flexible 10 mm² cable a suitable ferrule or ring is advisable to protect strands, and the conductor should be fully inserted with no copper visible outside the housing.
Commissioning checks should include a visual inspection and, for critical circuits, a thermographic scan under load to find loose joints. Replace any block whose housing shows heat marks.
Keep a record of the torque value and the conductor size used on each critical circuit, and mark the screw with a torque stripe after tightening. On later shutdowns, a broken stripe shows at a glance which clamps have moved. For circuits that carry large inrush currents, such as direct-on-line motor feeders, check the joint again after the first few weeks of operation, because thermal cycling can relax a clamp that was tightened only once.
Typical applications in Oman and the GCC
In Oman and the GCC the UT 6 is typical in 400 V motor control cabinets, power distribution boards for desalination pumps, and generator auxiliary panels. In hot cabinets the 1.31 W dissipation per block and the derating of the load current have to be added to the cabinet heat budget.
Its use in transformer and switchgear auxiliary wiring is also common, where robust screw clamps and high surge voltage rating (8 kV) matter.
Because the conductor range reaches 10 mm², the UT 6 is also a practical choice when site cable is heavier than the drawing assumed: the same block can still be used without redesign, which shortens commissioning delays on remote projects where a replacement part would take time to arrive.
Comparison with neighbouring UT sizes
| Device | Distinguishing data |
|---|---|
| UT 4 (3044102) | 32 A, 4 mm², M3 |
| UT 6 (this part, 3044131) | 41 A, 6 mm², M4, 1.31 W |
| UT 10 (3044160) | 57 A, 10 mm², M4, 1.82 W |
| UT 16 (3044199) | 76 A, 16 mm², M5, 2.43 W |
| UT 6-PE (3044157) | Protective earth block of the same size |
Information to send with an RFQ for the UT 6
- Full part number UT 6 and quantity in pieces (the page lists a packing unit of 50).
- Bridging requirement and bridge length.
- Wire sizes and cable type.
Site conditions in Oman for the UT 6
Control cabinets in Gulf plants often run hot, because many sit in outdoor kiosks or in rooms where air conditioning is not always reliable. Before you finalise the UT 6, check the permitted ambient range and any derating stated by the manufacturer against the real temperature inside your panel, and leave the recommended spacing around the device so that heat can escape. Long cable runs between the field and the marshalling cabinet are common on large sites, so confirm the signal types, wiring limits and earthing arrangement early in the design.
It also helps to standardise on a small number of part numbers across a project. Keeping a few spare UT 6 units on site in Oman shortens recovery time after a fault, and documenting configuration settings makes replacement faster for the maintenance team.
Documents and quotation
Send us the part number UT 6 and the quantity you need, and we will confirm which official documents are available for this item. Seven Star LLC is an independent supplier in Muscat and quotes for projects across Oman and the GCC; we do not act on behalf of the manufacturer.
Please also tell us the delivery location and the project timeline so that availability can be checked before you commit to a schedule.
Other Models in the Phoenix Ut Terminal Range
Seven Star LLC supplies models from the Phoenix Ut Terminal range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Phoenix Contact UT 4 Feed-Through Terminal Block, 32 A | Controllers & Data Acquisition | View details |
| Phoenix Contact UT 6 Feed-Through Terminal Block, 41 A | Controllers & Data Acquisition | You are viewing this model |
| Phoenix Contact UT 10 Feed-Through Terminal Block, 57 A | Controllers & Data Acquisition | View details |
| Phoenix Contact UT 16 Feed-Through Terminal Block, 76 A | Controllers & Data Acquisition | View details |
Reviews (0)
How would you rate this product? Cancel reply
About brand
Phoenix Contact is a German, family-owned manufacturer of electrical connection technology and industrial automation, founded in 1923 in Essen by Hugo Knümann. It began as a sales company, and in 1928 Knümann developed the modular terminal block mounted on a rail, the product the company is still best known for. Phoenix Contact is headquartered in Blomberg, North Rhine-Westphalia.
Seven Star LLC lists Phoenix Contact surge protection, power supplies and safety relays, and sources these components by order number for panel builders and maintenance teams in Oman.
Phoenix Contact company profile
| Founded | 1923, Essen, Germany, by Hugo Knümann, as Phönix Elektro- und Industrie-Bedarfsgesellschaft |
|---|---|
| Headquarters | Blomberg, Germany |
| Ownership | Family-owned (Eisert and Stührenberg families) |
| Key invention | The modular terminal block on a DIN rail, 1928 |
| Product families | CLIPLINE terminal blocks, PCB terminals and connectors, QUINT and TRIO power supplies, relay modules, surge protection, signal conditioners, Ethernet switches and PLCnext controllers |
Milestones
- 1923: Hugo Knümann founds the company in Essen.
- 1928: The first modular terminal block is developed.
- Later: Headquarters move to Blomberg, Ostwestfalen-Lippe.
Phoenix Contact parts listed on this page
The TTC-6-2X1-24DC-UT (order number 2906799) is a surge protection device with screw connection for two 24 V DC signal wires that share a common reference potential. The QUINT-PS/1AC/24DC/10 is a single-phase DIN rail power supply delivering 24 V DC at 10 A. The PSR-SCP-24DC/ESP4/2X1/1X2 (order number 2981020) is a single-channel PSR safety relay for emergency stop and safety door monitoring, with two enabling current paths and plug-in screw terminals.
Phoenix Contact products we list
Ordering Phoenix Contact components: what we need
Phoenix Contact items are ordered by a seven-digit order number together with the type designation, both printed on the side of the module. Send both, plus the quantity. If the number is unreadable, send the type text and a photo. For power supplies, state input voltage, output current and whether the unit runs in parallel or with a redundancy module. For buyers in the GCC replacing an older unit, we check the manufacturer's documentation for the listed successor type.
Facts checked against Phoenix Contact's own company history (phoenixcontact.com), October 2026.
Browse Phoenix Contact products by category: Isolator & Barrier, Power Modules, Automation Accessories.
FAQ
Questions about the Phoenix Contact UT 6 Feed-Through Terminal Block,
Answers from our engineering team on installation, compatibility and integration.
01What is the nominal current of the UT 6?
41 A at 1000 V, with a maximum load current of 57 A when 10 mm² conductor is used.
02Which wire sizes can the UT 6 take?
0.2 to 10 mm² for rigid and flexible conductors.
03What torque is used?
The M4 screw is tightened to 1.5 to 1.8 Nm.
04What is the power dissipation?
The page lists 1.31 W at nominal condition.
05Can blocks be bridged?
Yes; the data sheet gives 1000 V for adjacent bridging and 500 V for non-adjacent bridging.