Brand: Lovato Electric
Lovato LRD12RD024 Micro PLC Base Module, 24 V DC, 12 I/O
Description
Lovato LRD12RD024 micro PLC base module, 24 V DC, 12 I/O
The Lovato LRD12RD024 is a compact logic controller base module with 24 V DC supply, 6 digital inputs, 2 inputs usable as digital or analog, 4 relay outputs and a 4-line LCD. It is the standard, non-Ethernet counterpart of the LRK12RD024 and can be extended to 36 I/O with LRE expansion modules. Seven Star LLC supplies the LRD12RD024 in Oman and the GCC as an independent supplier in Muscat.
LRD is the series, 12 the I/O count, R the relay outputs, D the DC supply and 024 the 24 V level. The data sheet lists no communications port on this base module, so check the manual and catalogue for programming accessories before ordering.
LRD12RD024 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Lovato / LRD12RD024 |
| Supply | 24 V DC; 20.4 to 28.8 V DC |
| Current / power | 125 mA average; 4.5 W max |
| Inputs | 6 digital + 2 digital/analog |
| Digital input level | State 1 above 15 V DC |
| Response time | 4 ms; 0.5 ms / 0.3 ms high-speed |
| Analog inputs | 2, 0 to 10 V, 10-bit, 0.01 V resolution |
| Sampling time | 5 to 20 ms (ladder); 2 to 10 ms (FBD) |
| Outputs | 4 relay |
| Expansion | Up to 36 points with LRE modules |
| Display | LCD 4 x 16 characters |
| Terminals | 0.14 to 2.5 mm²; 0.6 Nm |
| Temperature | -20 to +55 °C; 20 to 90% RH non-condensing |
| Mounting | 35 mm rail or M4 screws |
| Protection | IP20 |
| Dimensions / weight | 72 x 106 x 59.6 mm; 241 g |
How the LRD12RD024 differs from the LRK12RD024
The two modules share housing, I/O count and relay outputs but differ in important details. The LRD12RD024 needs a regulated 24 V DC with a 20.4 to 28.8 V window, draws 125 mA and has an input threshold of 15 V DC, whereas the LRK12RD024 runs from 12 or 24 V, draws 300 mA and switches at 10 V DC. The analog conversion is 10-bit on the LRD against 12-bit on the LRK, and the LRD allows +55 °C operation against +50 °C. Choose by supply, resolution and communication needs.
Programming languages and scan times
The data sheet quotes a sampling time of 5 to 20 ms for ladder programs and 2 to 10 ms for function block diagrams, which indicates both languages are supported. These times are fine for pump sequences, timers and level control, but not for fast motion control.
Where the LRD12RD024 fits
Typical tasks are start-stop logic, alternation of two pumps, sequencing of compressors, light and ventilation control, and alarm annunciation. Pair it with a PSL1M06024 power supply, which delivers 24 V DC, 2.5 A, enough for the controller and its field devices. Output relays can drive Lovato BF contactors or relays like the HR301CA230 through the DIN rail.
LRD12RD024 selection and ordering checklist
- Count inputs and outputs, with spare
- Confirm regulated 24 V DC supply is available
- Check relay ratings against loads
- Decide whether Ethernet is needed; if so, consider the LRK12RD024
- Plan expansion modules
- Check +55 °C panel limit
Installation and commissioning of the LRD12RD024
Install in a clean cabinet on DIN rail, fit surge suppressors on coil loads and keep analog wires shielded. Load the program, test inputs from the display and force outputs with the motors disconnected. Keep a copy of the program with the cabinet drawings.
Typical LRD12RD024 applications in Oman and the GCC
Typical applications are packaged water booster sets, jockey and standby pump control, generator room ventilation, tank-filling control and small conveyors. In the Gulf climate the 20 to 90 percent humidity limit is rarely reached indoors, but condensation in outdoor panels is possible and the controller is not rated for it.
Worked example: duplex pump control on the LRD12RD024
A duplex sump station needs two pump inputs for overload trips, three level float inputs (low, high, high-high), and two outputs for the pump contactors plus one for an alarm. That is six inputs and three outputs, well within the 8 inputs and 4 outputs of this module. The program alternates the lead pump on every cycle, starts the second pump on the high float, forces both on at high-high and sets the alarm if a pump overload input is active. The four relay outputs drive the contactor coils directly if each coil draws less than the relay rating, and otherwise through interposing relays.
The two analog inputs can read a 0 to 10 V level transmitter, which allows an additional analogue setpoint for the same station. At 10-bit resolution the steps are about 10 mV, adequate for level but not for fine process control. A PSL1M06024 supply feeds the controller and the float switches.
Maintenance notes for the LRD12RD024
Inspect terminals annually, clear dust from the housing vents and verify that the supply stays inside the 20.4 to 28.8 V DC window, since a sagging 24 V rail is the most common cause of random resets. Back up the program after every change.
Information to send with an RFQ for the LRD12RD024
- Part number LRD12RD024 and quantity
- Input and output counts
- Supply available
- Communication needs
- Panel temperature
- Delivery location
Site conditions in Oman for the LRD12RD024
Control cabinets in Gulf plants often run hot, because many sit in outdoor kiosks or in rooms where air conditioning is not always reliable. Before you finalise the LRD12RD024, check the permitted ambient range and any derating stated by the manufacturer against the real temperature inside your panel, and leave the recommended spacing around the device so that heat can escape. Long cable runs between the field and the marshalling cabinet are common on large sites, so confirm the signal types, wiring limits and earthing arrangement early in the design.
It also helps to standardise on a small number of part numbers across a project. Keeping a few spare LRD12RD024 units on site in Oman shortens recovery time after a fault, and documenting configuration settings makes replacement faster for the maintenance team.
Documents and quotation
Send the part number LRD12RD024 and we will confirm the documents available for it, such as the technical data sheet, wiring diagram and instruction sheet, together with availability and lead time.
Seven Star LLC is an independent supplier in Muscat and is not an official channel of the manufacturer. Share the quantity, delivery location and project reference with the request and we will answer with a formal quotation.
Other Models in the Lovato Micro Plc Range
Seven Star LLC supplies models from the Lovato Micro Plc range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Lovato LRK12RD024 Micro PLC Base Module, Ethernet, 12/24 V DC | Logic Controllers | View details |
| Lovato LRD12RD024 Micro PLC Base Module, 24 V DC, 12 I/O | Logic Controllers | You are viewing this model |
Reviews (0)
How would you rate this product? Cancel reply
About brand
Lovato Electric is the Italian manufacturer of low-voltage electrical components for industrial automation and power distribution: contactors, motor protection circuit breakers, soft starters, variable speed drives, power factor controllers, transfer switch and generator controllers, and energy meters. It was founded in Bergamo in 1922 and has been run by the same family for four generations. Its headquarters is in Gorle, near Bergamo, and it celebrated its centenary in 2022.
Seven Star LLC is an independent supplier in Muscat. We list Lovato motor control, drives and power management products, and supply them to panel builders, contractors and maintenance teams in Oman and the GCC by order code.
Lovato Electric at a glance
| Established | 1922, Bergamo, Italy |
|---|---|
| Headquarters | Gorle (Bergamo), Italy |
| Ownership | Private, family-run for four generations |
| Product families | Contactors and relays, motor protection circuit breakers, motor starters, soft starters, variable speed drives, power factor controllers, ATS and gen-set controllers, multimeters and energy meters, micro PLCs |
Lovato products we list
| Family | Models | Typical use |
|---|---|---|
| Contactors | BF0910A230, BF1810A230, BF2510A230, BF2600A230, BF09T4A230 4-pole, BFS0923A024, 11BG0910A230 mini, 11BGR0901A048 reversing | Switching motors, heaters, lighting and capacitor banks |
| Motor protection and starters | SM1P0650, SM1P1000, SM1P3200, M1P enclosed DOL starter, ME024FD024, ME070RSD024, 31L48 time relay | Short-circuit and overload protection and direct starting of motors |
| Soft starters | ADXL0030600, ADXL0085600, ADXL0135600, ADXT0034, ADXT0084, ADXT0139 | Reducing starting current and mechanical shock on pumps, fans and compressors |
| Variable speed drives | VLA1, VLB1, VLB3 0.75 kW, VLB3 2.2 kW, VLB3 5.5 kW, VLB3 22 kW, VT1 | Speed control of pumps, fans and conveyors to save energy |
| Power management and control | DCRG8, DCRL8 PF controllers, ATL600 ATS controller, RGK600 gen-set controller, DMG200 multimeter, DMED300T2 energy meter, LRD20 micro PLC | Power factor correction, mains/generator changeover and energy monitoring |
Lovato order codes describe the product. On a contactor such as BF0910A230, "BF09" is the frame and rated current (9 A in AC-3), "10" is the built-in auxiliary contact (one normally open), "A" means an AC coil and "230" is the coil voltage. The coil voltage must match the control circuit exactly, so it is the most common detail to check when replacing one. For motors, a soft starter limits the inrush current at start and stop, while a variable speed drive controls the speed continuously and saves energy on pumps and fans that do not need full flow all the time.
Where Lovato products are used
In Oman and the GCC, Lovato components are built into motor control centres, pump and HVAC panels, capacitor banks for power factor correction, generator and ATS panels, and machine control panels for industry, water and buildings.
Ordering Lovato products: what we need
Send the full Lovato order code. For contactors and starters, confirm the coil or control voltage. For drives and soft starters, send the motor power, current and supply voltage. For power factor controllers, send the number of steps and the CT ratio.
Facts checked against Lovato Electric company profile brochures, October 2026.
Browse Lovato Electric products by category: Motor Soft Starters, Automation Accessories, Controllers & Data Acquisition, PLC & I/O Cards, Circuit Breakers, Diesel Generator Spare Parts.
FAQ
Questions about the Lovato LRD12RD024 Micro PLC Base Module, 24 V DC,
Answers from our engineering team on installation, compatibility and integration.
01What supply voltage does the LRD12RD024 need?
24 V DC, with an operating range of 20.4 to 28.8 V DC.
02How many I/O does it have?
6 digital inputs, 2 digital/analog inputs and 4 relay outputs; up to 36 points with expansion.
03What is the analog resolution?
10-bit, 0 to 10 V with 0.01 V resolution.
04Is it the same as the LRK12RD024?
No; the LRK12RD024 has Ethernet, a 12/24 V supply and 12-bit analog inputs.
05What temperature range applies?
-20 to +55 °C operating.


















Reviews