Schneider Electric SR2B201BD Zelio Logic 20 I/O 24 V DC Smart

Description

SR2B201BD compact smart relay with display and clock

The SR2B201BD is a Schneider Electric product listed in the datasheet as: compact smart relay, Zelio Logic SR2 SR3, 20 IO, 24V DC, clock, display, 8 relay outputs. The SR2B201BD is a Zelio Logic compact smart relay with 20 I/O, 24 V DC supply, display and clock. It replaces a group of relays and timers on simple control tasks without needing a PLC. Seven Star LLC supplies the SR2B201BD in Oman and the GCC as an independent supplier based in Muscat.

Reading the reference: SR2 is the compact Zelio Logic range, B the 20 I/O base with display and clock, 20 the I/O, 1 the relay outputs and BD the 24 V DC supply. The datasheet title lists 8 relay outputs.

Technical specifications of the SR2B201BD

Parameter Specification
Manufacturer / part number Schneider Electric / SR2B201BD
Description compact smart relay, Zelio Logic SR2 SR3, 20 IO, 24V DC, clock, display, 8 relay outputs
Range of Product Zelio Logic
Product or Component Type Compact smart relay
Local display With
Number or control scheme lines 0 to 240 ladder; 0 to 500 FBD
Cycle time 6 to 90 ms
Backup time 10 years 25 °C
Clock drift 12 min/year 0 to 55 °C; 6 s/month 25 °C
Checks Program memory on each power up
[Us] rated supply voltage 24 V DC
Supply voltage limits 19.2 to 30 V
Maximum supply current 100 mA without extension
Power dissipation in W 6 W without extension
Reverse polarity protection With
Discrete input number 12 IEC 61131-2 Type 1
Discrete input type Resistive
Discrete input voltage 24 V DC
Discrete input current 4 mA
Counting frequency 1 kHz discrete input
Voltage state 1 guaranteed >= 15 V I1–IA and IH–IR discrete input circuit; >= 15 V IB–IG used as discrete input circuit
Voltage state 0 guaranteed <= 5 V I1–IA and IH–IR discrete input circuit; <= 5 V IB–IG used as discrete input circuit
Current state 1 guaranteed >= 1.2 mA IB–IG used as discrete input circuit; >= 2.2 mA I1–IA and IH–IR discrete input circuit
Current state 0 guaranteed <= 0.75 mA I1–IA and IH–IR discrete input circuit; <= 0.75 mA IB–IG used as discrete input circuit
Input compatibility 3-wire proximity sensors PNP discrete input
Analogue input number 6
Analogue Input Type Common mode
Analogue input range 0 to 24 V; 0 to 10 V
Temperature probe type NTC 10k 25 °C; NTC 1000k 25 °C; KTY81 210/220/221/222/250; Pt 500
Maximum permissible voltage 30 V analogue input circuit
Analogue input resolution 8 bits
LSB value 39 mV analogue input circuit
Conversion time Smart relay cycle time analogue input circuit
Conversion error ± 5 % 25 °C analogue input circuit; ± 6.2 % 55 °C analogue input circuit
Repeat accuracy ± 2 % 55 °C analogue input circuit
Operating distance 10 m between stations, with screened cable (sensor not isolated) analogue input circuit
Input impedance 12 kOhm IB–IG used as analogue input circuit; 12 kOhm IB–IG used as discrete input circuit
Number of Outputs 8 relay
Output voltage limits 24 to 250 V AC relay output; 5 to 30 V DC relay output
Contacts type and composition NO relay output
Output thermal current 8 A for all 8 outputs relay output
Electrical durability AC-12 500000 cycles 230 V, 1.5 A relay output IEC 60947-5-1; AC-15 500000 cycles 230 V, 0.9 A relay output IEC 60947-5-1

Inputs, outputs and programming of the SR2B201BD

Supply voltage: 24 V DC. Supply voltage limits: 19.2 to 30 V. Contacts: NO relay output. Discrete inputs: 12 IEC 61131-2 Type 1. Analogue inputs: 6. Analogue input types: Common mode. Input resolution: 8 bits. Input voltage: 24 V DC. Output voltage: 24 to 250 V AC relay output; 5 to 30 V DC relay output. Mechanical durability: 10000000 cycles relay output. Electrical durability: AC-12 500000 cycles 230 V, 1.5 A relay output IEC 60947-5-1; AC-15 500000 cycles 230 V, 0.9 A relay output IEC 60947-5-1.

The device is programmed either on the front keypad in ladder or function-block form, or from a PC with Zelio Soft. The display and the clock let it run time-based control such as scheduled starts.

Where the SR2B201BD fits

Smart relays suit small, fixed sequences: alternating pumps, lighting timers, door control or simple alarm logic. A PLC such as Modicon M221 is better if you need network connection or extensive expansion.

Selection checklist for the SR2B201BD

  • Supply voltage 24 V DC.
  • Number of I/O needed: 20.
  • Display and clock requirement.
  • Software.
  • Expansion modules.
  • Environment.

Programming and backing up the SR2B201BD

Program via the keypad or the PC, simulate before download and store the program on a memory cartridge if available.

Label the inputs and outputs on the panel.

Typical applications of the SR2B201BD in Oman and the GCC

In Oman and the GCC smart relays run small pump alternation, ventilation timers and basic automation in utility buildings.

Dimensions, environment and approvals of the SR2B201BD

The SR2B201BD weighs 0.38 kg. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.

Ambient temperature limits in the datasheet: -20 to 40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC. Relative humidity: 95 % without condensation or dripping water. Ingress protection: IP20 IEC 60529 terminal block; IP40 IEC 60529 front panel. Operating altitude: 2000 m. Standards listed: IEC 61000-4-2 level 3; IEC 61000-4-5; IEC 60068-2-27 Ea; IEC 61000-4-12; IEC 61000-4-3; IEC 60068-2-6 Fc; IEC 61000-4-6 level 3. Certifications listed for this reference: GOST; UL; CSA; C-tick; GL.

Information to send with an RFQ for the SR2B201BD

  • Full reference and quantity required
  • Existing equipment, panel or rack it must fit
  • Supply voltage, load or signal details of the application
  • Required delivery location and timing
  • Whether a spare, a replacement or a new installation

Documents and quotation

A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.

Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.

Datasheets & Documents
  • PDF Datasheet Schneider Electric SR2B201BD Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric SR2B201BD Zelio Logic 20 I/O 24

Answers from our engineering team on installation, compatibility and integration.

01What is the net weight of the SR2B201BD?
The datasheet gives 0.38 kg.
02What ingress protection does the SR2B201BD list?
Stated as IP20 IEC 60529 terminal block; IP40 IEC 60529 front panel.
03Which standards does the SR2B201BD list?
Listed: IEC 61000-4-2 level 3; IEC 61000-4-5; IEC 60068-2-27 Ea; IEC 61000-4-12; IEC 61000-4-3; IEC 60068-2-6 Fc; IEC 61000-4-6 level 3; IEC 61000-4-4 level 3; IEC 61000-4-11.
04Which product range does the SR2B201BD belong to?
The datasheet lists the range as Zelio Logic.
05What mechanical durability does the SR2B201BD list?
Stated as 10000000 cycles relay output.