- Automation & ControlView all 3,087 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Oldham
Oldham MX 43 Gas Detection Controller
Description
Overview
The Oldham MX 43 is an analog and digital gas detection controller from Teledyne Oldham Simtronics for the continuous measurement and control of gases in the atmosphere. It accepts both 4-20 mA analog detectors and addressable digital lines, so one panel can serve a small plant room or a site with up to 32 detectors spread over 8 lines. The controller is fully scalable, has SIL1 capability according to EN 50271 and is offered in wall-mounted and 19-inch rack versions with 4 or 8 lines.
Seven Star LLC supplies the Oldham MX 43 to oil and gas facilities, utilities, industrial plants, car parks, laboratories and commercial buildings in Oman and the GCC. Our engineers in Muscat help customers size the controller, choose modules and match it to existing detectors, and we provide engineering support for sites in Muscat, Sohar, Duqm and Salalah.
Operating Principle
Detectors report their gas concentration to the Oldham MX 43 either as a 0-23 mA analog signal, with 4 to 20 mA reserved for measurement, or over digital lines that use RS-485 communication with a proprietary protocol at 9600 baud on a twisted shielded pair. Using digital lines, up to 32 detectors can be spread over 8 lines, which reduces cabling cost compared with a home-run cable for every detector. Each line can supply 1.2 A (1.5 A intermittently) to the field, with 2.4 A permanent in total.
For every channel the Oldham MX 43 evaluates three alarm levels, overscale, underscale and fault, using instantaneous or averaged values, rising or falling thresholds and manual or automatic acknowledgement. A non-ambiguity reading option is available for combustible gas monitoring. Relay logic is built in the COM 43 configuration software with up to five functions (OR, AND, NOR, NAND and VOTING) and several timers, and audible alarms support acknowledgement, reactivation and evacuation sequences.
Engineering Design of the Oldham MX 43
The Oldham MX 43 front panel combines a back-lit graphic LCD with smart keys and seven LEDs per line for detector status, plus common LEDs for fault and power. The display can show 1 to 16 channels at once, fixed or scrolling, with bar graphs and alarm thresholds, and it switches to reverse video in alarm so the affected detector is identified immediately. Calibration is simplified for non-intrusive, one-person work, with a calibration curve and cursors for zero and span shown on screen.
The wall-mounted housing measures 370 × 299 × 109 mm with IP55 protection, while the rack version is a 19-inch 4U unit with IP31. Power comes from 100 to 240 VAC or 21 to 28 VDC, with an optional embedded back-up battery. Five fully programmable DPCO alarm relays rated 250 VAC 2 A and one fault relay are on board, and a Modbus RTU RS-485 link connects the controller to a PLC or building management system. Optional addressable modules include 4 or 8-relay modules, a 16-logic-input module, an 8-analog-input module and a 4-analog-output module, and a USB option logs gas measurements every 2 seconds to 15 minutes.
Key Features
The Oldham MX 43 brings the following capabilities to fixed gas detection systems:
- Mixed analog and digital architecture with 4 or 8 lines and up to 32 detectors.
- Wall-mounted 4-line, 8-line and analog-board versions, plus an 8-line 19-inch rack version.
- Large back-lit graphic display with customisable views of up to 16 detectors and bar graphs.
- Three alarm levels per channel plus overscale, underscale and fault, with averaged or instantaneous thresholds.
- Five programmable relays with OR, AND, NOR, NAND and VOTING logic configured in COM 43 software.
- Addressable relay, logic input, analog input and analog output modules located close to the field equipment.
- Event memory of 512 alarm, 512 fault and 512 system events and optional USB data logging.
- SIL1 capability to EN 50271 and metrological performance according to EN 60079-29-1.
Industrial Applications
The Oldham MX 43 suits compressor houses, turbine enclosures, metering skids, battery rooms, boiler houses, chlorination rooms, underground car parks, laboratories and warehouses where several gases or zones must be monitored from one panel. The logic input module lets the Oldham MX 43 collect fire alarms, intrusion alarms, emergency stops and limit switches, and the analog output module passes detector values, minimum, maximum or group averages to a data logger, PLC or BMS. The E-4 and E-8 versions with analog boards are intended for replacing an existing MX42 or MX48 central unit with bridge sensors.
In Oman, the Oldham MX 43 is a practical choice for gas stations and compressor sites in the interior, utilities and desalination plants on the coast, industrial units in the Sohar, Duqm and Salalah zones, and commercial buildings in Muscat. Seven Star LLC supplies it with compatible detectors and alarms such as the Oldham OLCT 100 fixed gas detector, the Oldham MX 62 controller for larger systems and the E2S BExCS110-05 explosion-proof alarm and beacon.
Technical Specifications
The Oldham MX 43 values below are taken from the Teledyne Oldham Simtronics MX 43 controller brochure.
| Parameter | Specification |
|---|---|
| Model | Oldham MX 43 gas detection control panel (WMX43 M-4, M-8, R-8, E-4, E-8) |
| Dimensions | Wall: 370 × 299 × 109 mm; rack: 19 in, 4U, 482.8 × 177 × 192.5 mm |
| Ingress protection | IP55 wall-mounted; IP31 rack |
| Cable entries (wall) | 2 × M16 and 6 × M20 cable glands |
| Display | Back-lit LCD with smart keys; 1 to 16 channels; reverse video on fault |
| Visual indicators | 7 LEDs per line; common fault and power LEDs |
| Power | 100-240 VAC 50-60 Hz or 21-28 VDC, 112 W max; optional 0.6 Ah back-up battery |
| Digital lines | 8 max; RS-485 proprietary protocol, 9600 baud, twisted shielded pair |
| Analog channels | 8 max; 0-23 mA input (4-20 mA measurement), 120 Ω load |
| Line output | 21 to 28 VDC; 1.2 A per line (1.5 A intermittent); 2.4 A total permanent |
| Alarms | A1, A2, A3, overscale, underscale and fault per channel |
| Relays | 5 programmable DPCO relays, 250 VAC 2 A; 1 fault relay |
| Digital output | RS-485 Modbus RTU |
| Operating temperature / humidity | -20 to +50 °C; 5 to 95% RH |
| Approvals | EN 50270 EMC; EN 50271 and EN 60079-29-1; EN 61010; FM 3600, FM 6320, ANSI/FM 60079-29-1 |
| Functional safety | SIL1 capability to EN 50271:2010; PFDavg 1.03 × 10-2 (4-channel, 24 VDC) |
How to Order
To order the Oldham MX 43, send Seven Star LLC an RFQ with the number of detectors and lines, the mounting version, the language, and whether you need the audible and visual alarm kit, battery, USB logging, COM 43 software or extra modules. Our team in Muscat will build the correct WMX43 order code, confirm availability and lead time, and the MX 43 brochure can be downloaded from this page. Seven Star LLC supplies Teledyne Oldham Simtronics controllers and detectors across Oman and the GCC with engineering support in Muscat.
See also: Oldham MX 32 Analog and Digital Gas Detection Controller.
Datasheets & Documents
- Brochure Oldham MX 43 Controller Brochure Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Oldham is the French gas detection brand known for the OLCT fixed detectors and the MX series controllers used in oil and gas, chemical and utility plants. Its factory in Arras, northern France, has made gas detection equipment since 1948. The brand is part of Teledyne Gas and Flame Detection today and trades as Teledyne Oldham Simtronics.
Seven Star LLC is an independent supplier in Muscat. We list Oldham fixed gas detectors, controllers and a transportable area monitor, and supply them and their spare sensors to plants in Oman and the GCC by model and gas type.
Oldham company profile
| Origin | Arras, France; manufacturing on the Arras site dates back to 1948 |
|---|---|
| Ownership history | Bought by Industrial Scientific in 2006. The fixed gas detection business was sold to Industrial Safety Technologies (IST) in 2013, which also owned Simtronics. It is now part of Teledyne Gas and Flame Detection. |
| Product families | Fixed detectors for combustible, toxic and oxygen gases (catalytic, infrared, electrochemical), gas detection controllers, and transportable area monitors |
| Applications | Wellheads, process units, compressor and pump houses, tank farms, analyser shelters, battery rooms, car parks and water treatment plants |
Milestones
- 1948: Manufacturing begins on the Arras site in France.
- 2006: Industrial Scientific buys Oldham.
- 2013: The fixed gas detection business is sold to Industrial Safety Technologies, which also owned Simtronics; it is now part of Teledyne Gas and Flame Detection.
Oldham products we list
| Model | Type | Typical use |
|---|---|---|
| OLCT 100, OLC100 / OLCT 100 IR | Fixed detector, explosion-proof | Combustible, toxic or oxygen detection in hazardous areas; the IR version uses an infrared sensor for hydrocarbons |
| OLCT 60, OLCT 80, OLCT 710 | Fixed detector transmitters | Industrial gas detection with 4-20 mA output to a controller or DCS |
| OLCT 10N | Digital detector | Combustible, toxic and oxygen detection on a digital bus in non-hazardous areas such as car parks and plant rooms |
| CTX 300 | Transmitter | Toxic, oxygen and refrigerant gas monitoring in safe areas |
| MX 32, MX 43, MX 62 | Gas detection controllers | Read the detectors, show gas levels, and drive alarms and relays; MX 62 handles the largest number of channels |
| BM 25A | Transportable area monitor | Temporary multi-gas monitoring during shutdowns, confined space work and hot work |
The sensor follows the gas. Catalytic bead sensors measure combustible gases in % LEL, infrared sensors measure hydrocarbons and do not need oxygen or suffer from poisoning, and electrochemical cells measure toxic gases such as H2S and CO and oxygen in ppm or % volume. A fixed system is a loop: the detectors in the field, a controller such as the MX 43 that sets alarm thresholds, and the relays that trip ventilation, shutdown valves or sounders.
Where Oldham gas detection is used
In Oman and the GCC, Oldham detectors and controllers protect oil and gas production stations, refineries, gas plants, fuel depots, water and wastewater plants, and building plant rooms, often for H2S and combustible gas.
Ordering Oldham equipment: what we need
Send the model, the gas and measuring range, the sensor type (catalytic, infrared or electrochemical), the hazardous area classification and the output (4-20 mA or digital). For controllers, add the number of channels and relays. For spare sensors, send the part number from the detector label.
Facts checked against Teledyne Gas and Flame Detection and Industrial Scientific company information, October 2026.
Browse Oldham products by category: Fire & Gas Detector, Logic Controller.
FAQ
Questions about the Oldham MX 43 Gas Detection Controller
Answers from our engineering team on installation, compatibility and integration.
01How many detectors can the Oldham MX 43 handle?
It manages up to 8 digital lines and 8 analog channels. With digital lines, up to 32 detectors can be spread over 8 lines, while 4-line versions support up to 16 detectors.
02Which detectors can be connected to the MX 43?
Any standard 4-20 mA gas or flame detector can be connected to the analog channels or to an 8-analog-input module on a digital line. Digital lines carry addressable detectors and modules. The MX 43 brochure presents it alongside the Teledyne fixed detector range, including the OLCT 10, OLCT 10N, OLCT 100, OLCT 80, OLCT 60 and 700 Series.
03Can the MX 43 send data to a PLC or BMS?
Yes. It has a Modbus RTU RS-485 output, and an optional addressable 4-analog-output module provides 4-20 mA copies of detector values or the minimum, maximum or average of a group of detectors.
04Is the MX 43 suitable for safety-related applications?
The controller has SIL1 capability according to EN 50271:2010, with a PFDavg of 1.03 × 10-2 for the 4-channel, 24 VDC version, and its metrological performance follows EN 60079-29-1.
05Does Seven Star LLC supply the Oldham MX 43 in Oman?
Seven Star LLC supplies the Oldham MX 43, its modules and compatible detectors to customers in Oman and the GCC, with engineering support in Muscat. Share your detector list and we will confirm the right version and order code.


















Reviews
There are no reviews yet.