Schneider Electric TM221CE16R Modicon M221 16 I/O Ethernet

Description

TM221CE16R 16-point compact controller with Ethernet

The TM221CE16R is a Schneider Electric product listed in the datasheet as: logic controller, Modicon M221, 16 IO, 9 DI, 7 DO, relay, Ethernet. The TM221CE16R is a Modicon M221 compact controller with 9 digital inputs, 7 relay outputs and an Ethernet port. It brings network connectivity to a very small machine or pump panel without needing a bigger controller. Seven Star LLC supplies the TM221CE16R in Oman and the GCC as an independent supplier based in Muscat.

Reading the reference: TM221 is the M221 family, CE marks the compact version with Ethernet, 16 is the I/O count (9 DI and 7 DO as stated in the title) and R is relay output.

Technical specifications of the TM221CE16R

Parameter Specification
Manufacturer / part number Schneider Electric / TM221CE16R
Description logic controller, Modicon M221, 16 IO, 9 DI, 7 DO, relay, Ethernet
Range of Product Modicon M221
Product or Component Type Logic controller
[Us] rated supply voltage 100 to 240 V AC
Discrete input number 9, discrete input IEC 61131-2 Type 1
Analogue input number 2 0 to 10 V
Discrete output type Relay normally open
Discrete output number 7 relay
Discrete output voltage 5 to 125 V DC; 5 to 250 V AC
Discrete output current 2A
Discrete I/O number 16
Maximum number of I/O 4 (local I/O-Architecture)
expansion module 11 (remote I/O-Architecture)
Supply voltage limits 85 to 264 V
Network Frequency 50/60 Hz
Inrush current 40 A
Maximum power consumption in 49 VA 100 to 240 V with max number of I/O expansion module
VA 33 VA 100 to 240 V without I/O expansion module
Power supply output current 0.325 A 5 V expansion bus; 0.12 A 24 V expansion bus
Discrete input logic Sink or source (positive/negative)
Discrete input voltage 24 V
Discrete input voltage type DC
Analogue input resolution 10 bits
LSB value 10 mV
Conversion time 1 ms per channel + 1 controller cycle time analog input
Permitted overload on inputs ± 30 V DC 5 min maximumanalog input; ± 13 V DC permanentanalog input
Voltage state 1 guaranteed >= 15 V input
Voltage state 0 guaranteed <= 5 V input
Discrete input current 7 mA discrete input; 5 mA fast input
Input impedance 3.4 kOhm discrete input; 100 kOhm analog input; 4.9 kOhm fast input
Response time 35 µs turn-off, I2–I5 input; 10 ms turn-on output; 10 ms turn-off output; 5 µs turn-on, I0, I1, I6, I7 fast input
Configurable filtering time 0 ms input; 3 ms input; 12 ms input
Output voltage limits 125 V DC; 277 V AC
Maximum current per output 6 A COM 1
common 7 A COM 0
Absolute accuracy error ± 1 % of full scale analog input
Electrical durability 100000 cycles AC-12, 120 V, 240 VA, resistive; 100000 cycles AC-12, 240 V, 480 VA, resistive; 300000 cycles AC-12, 120 V, 80 VA, resistive
Switching frequency 20 switching operations/minute with maximum load
Mechanical durability 20000000 cycles relay output
Minimum load 1 mA 5 V DC relay output
Protection type Without protection 5 A

Inputs, outputs and Ethernet of the TM221CE16R

Supply voltage: 100 to 240 V AC. Supply voltage limits: 85 to 264 V. Network frequency: 50/60 Hz. Discrete inputs: 9, discrete input IEC 61131-2 Type 1. Discrete outputs: 7 relay. Discrete I/O: 16. Analogue inputs: 2 0 to 10 V. Input resolution: 10 bits. Input voltage: 24 V. Output type: Relay normally open. Output voltage: 5 to 125 V DC; 5 to 250 V AC. Output current: 2A. Ethernet: 10BASE-T/100BASE-TX 1 100 m copper cable. Communication protocols: USB port USB – SoMachine-Network; Non isolated serial link Modbus master/slave – RTU/ASCII or SoMachine-Network; Ethernet. Output current: 0.325 A 5 V expansion bus; 0.12 A 24 V expansion bus. Output voltage: 125 V DC; 277 V AC. Mechanical durability: 20000000 cycles relay output. Electrical durability: 100000 cycles AC-12, 120 V, 240 VA, resistive; 100000 cycles AC-12, 240 V, 480 VA, resistive; 300000 cycles AC-12, 120 V, 80 VA, resistive.

The Ethernet port gives remote programming and Modbus TCP connection to a SCADA or HMI. Relay outputs allow direct switching of contactor coils and signal lamps.

Choosing the TM221CE16R instead of the TM221C24R

The TM221C24R has more I/O but no Ethernet. If the machine needs network access but few points, the TM221CE16R is the right base, and I/O can be added with TM3 expansion modules. Networking should be assessed with the plant IT group, and the controller should be set with a fixed IP address.

Selection checklist for the TM221CE16R

  • Digital inputs: 9; outputs: 7 relay.
  • Ethernet requirement.
  • Expansion plans.
  • Supply voltage.
  • HMI or SCADA link.
  • Spare unit for the same program.

Network set-up and checks of the TM221CE16R

Assign a static IP address, change default credentials where the software supports it and document the address. Test communication with the HMI before site delivery.

Restrict access by network segmentation, since a controller on an open network is a security risk.

Typical applications of the TM221CE16R in Oman and the GCC

In Oman and the GCC networked small controllers appear in booster stations, tank farms with few signals and small packaged equipment with remote monitoring.

Dimensions, environment and approvals of the TM221CE16R

For the TM221CE16R, plan the mounting space from the datasheet: 95 mm (W) x 90 mm (H) x 70 mm (D). The TM221CE16R weighs 0.346 kg. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.

Ambient temperature limits in the datasheet: -10 to 55 °C horizontal installation. Relative humidity: 10 to 95 %, without condensation in operation; 10 to 95 %, without condensation in storage. Ingress protection: IP20 with protective cover in place. Operating altitude: 0 to 2000 m. Vibration resistance: 3.5 mm 5 to 8.4 Hz symmetrical rail; 3.5 mm 5 to 8.4 Hz panel mounting; 1 gn 8.4 to 150 Hz symmetrical rail; 1 gn 8.4 to 150 Hz panel mounting. Shock resistance: 98 m/s² 11 ms. Standards listed: IEC 61131-2; UL 508; CAN/CSA C22.2 No. 213; IACS E10; ANSI/ISA 12-12-01. Certifications listed for this reference: cULus; LR; RCM; EAC; ABS; DNV-GL; CE; UKCA cULus HazLoc.

Information to send with an RFQ for the TM221CE16R

  • Full reference and quantity required
  • Existing equipment, panel or rack it must fit
  • Supply voltage, load or signal details of the application
  • Required delivery location and timing
  • Whether a spare, a replacement or a new installation

Documents and quotation

A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.

Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.

Other Models in the Se M221 Range

Seven Star LLC supplies models from the Se M221 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric TM221CE24R M221 Logic Controller 24 I/O RelayLogic ControllersView details
Schneider Electric TM221CE40T M221 Logic Controller 40 I/O PNPLogic ControllersView details
Schneider Electric TM221C24R Modicon M221 24 I/O RelayLogic ControllersView details
Schneider Electric TM221CE16R Modicon M221 16 I/O EthernetLogic ControllersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Schneider Electric TM221CE16R Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric TM221CE16R Modicon M221 16 I/O

Answers from our engineering team on installation, compatibility and integration.

01What is the net weight of the TM221CE16R?
The datasheet gives 0.346 kg.
02What ingress protection does the TM221CE16R list?
Stated as IP20 with protective cover in place.
03Which standards does the TM221CE16R list?
Listed: IEC 61131-2; UL 508; CAN/CSA C22.2 No. 213; IACS E10; ANSI/ISA 12-12-01.
04Which product range does the TM221CE16R belong to?
The datasheet lists the range as Modicon M221.
05What mechanical durability does the TM221CE16R list?
Stated as 20000000 cycles relay output.