Endress+Hauser CM444R Liquiline DIN-Rail Transmitter

Description

Endress+Hauser CM444R Liquiline DIN-rail 4-channel transmitter

The Endress+Hauser CM444R is a Liquiline transmitter in a compact DIN-rail housing that takes up to four digital Memosens sensors from more than twelve measured parameters. It fits into any control cabinet, and it can be extended at any time with additional inputs, outputs, controllers, math modules and sensor channels. The CM444R is a four-wire device: it handles pH, ORP, ISFET, conductive and inductive conductivity, dissolved oxygen, nitrate and turbidity in any combination, and it outputs through 0/4 to 20 mA, relays and fieldbuses. Seven Star LLC supplies the CM444R in Oman and the GCC as an independent supplier in Muscat.

CM444R technical specifications

Parameter Specification
Manufacturer / part number Endress+Hauser / Liquiline CM444R
Inputs 1 to 4 x Memosens; 2 x 0/4 to 20 mA; optional 2 to 4 digital inputs
Parameters pH, ORP, ISFET, conductivity, dissolved oxygen, nitrate, turbidity
Outputs 2 to 8 x 0/4 to 20 mA; alarm relay and 4 relays
Fieldbus PROFIBUS DP, Modbus RS485, Modbus TCP, Ethernet
Supply 100 to 230 V AC or 24 V AC/DC
Dimensions 220 x 100 x 97 mm
Protection IP20; display IP66
Housing PC-FR, EPDM display seal
Memory SD card

CM444R inputs, outputs and options

The base device has one to four Memosens digital inputs and two 0/4 to 20 mA inputs, with two to four optional digital inputs. Outputs are two to eight 0/4 to 20 mA current outputs, an alarm relay and up to four further relays (alarm relay rated 0.5 A, other relays 2.0 A). Fieldbus options are PROFIBUS DP, Modbus RS485, Modbus TCP and Ethernet, with HART, EtherNet/IP and PROFINET available on the platform. An SD card supports software update and copy-and-paste of the setup. Supply is 100 to 230 V AC or 24 V AC/DC (50/60 Hz) depending on version.

Housing and environment

The DIN-rail housing is PC-FR, 220 by 100 by 97 mm, with IP20 protection for the transmitter and an optional display with IP66 and EPDM seal. The product page gives an operating temperature of 0 to 55 °C for the transmitter; check the ambient limits in the document for your installation. Because the housing is not weather-proof, it must be installed in a cabinet or a protected control room.

Control and dosing functions

The Liquiline platform includes controller functions, so the CM444R can regulate dosing from a measured value. The document shows an example for chlorine regulation: a flow proximity switch on a digital input stops dosing if there is no flow, feed-forward from a flow signal on a current input trims the dose, and a pulse-frequency-modulated dosing pump is driven from a digital output. Measuring range switching for conductivity can be done through the Modbus module, and cleaning functions can be assigned to relays.

Selecting the CM444R

List the sensors and parameters first, then calculate the channel count; four Memosens inputs are on the base device, and additional channels need another unit. Choose the fieldbus and the number of current outputs, whether relays are needed, the supply voltage, and whether a remote display or a service display is required. The CM444R is for non-hazardous areas; for hazardous areas the Liquiline transmitters with the appropriate approval must be selected.

Installing and commissioning the CM444R

Snap the device on the DIN rail, install the modules in the slot order, connect the Memosens cables and wire the current outputs and relays. Inputs are assigned to measuring channels in ascending order of slots and ports, so the label CH1:1 means channel 1 on slot 1, port 1. Set the sensor type, units and calibration, assign the outputs, and save the setup to the SD card.

CM444R in Oman and the GCC

In the Gulf the CM444R is used in water and wastewater treatment, desalination pre-treatment and post-treatment, cooling and boiler water, and industrial effluent where several sensors must be gathered in a clean cabinet. Remote pumping and treatment sites benefit from the Modbus or PROFIBUS link to the plant control system, and from the web server for diagnostics.

CM444R compared with the CM442R and CM448R

Model Memosens channels
CM442R Up to 2
CM444R Up to 4
CM448R Up to 8

Information to send with a CM444R RFQ

  • Sensors, parameters and channel count
  • Number of current outputs and relays
  • Fieldbus protocol
  • Supply voltage and display
  • Dosing or control functions
  • Quantity and delivery location

Spares, expansion and documentation for the CM444R

Because the platform is modular, the best spare strategy is to keep one spare of each module type used in your measuring points, such as the base module, an extension module and the display, plus the Memosens cables. Save the setup to the SD card after every change, and keep a printed list of channel, slot and port assignment so that a replacement unit can be configured quickly. When extending the system later, add modules to the existing device rather than adding another transmitter if free slots allow.

Site conditions in Oman for the CM444R

Field instruments in Oman are exposed to strong sun, high ambient temperature, wind-blown dust and, on coastal plants, salt in the air. When you specify the CM444R, check the ambient and process temperature limits, the enclosure rating and the wetted and housing materials against the actual installation point, and consider sunshades for transmitters mounted in direct sunlight. Cable entries should be sealed with suitable glands so that dust and moisture cannot enter the housing.

Calibration and verification planning matters as much as selection. Record the range, configuration and tag data of each CM444R at commissioning, define a check interval that suits the criticality of the loop, and keep the certificates with the plant documentation so that audits and shutdown work can proceed without delay.

Documents and quotation

A copy of the manufacturer technical information for the CM444R is attached on this page so you can check ranges, connections and ordering codes against your specification. The attached document covers the CM442R, CM444R and CM448R DIN-rail versions.

Send the full order code or the process data (fluid, temperature, pressure, line size or tank data, output and approvals) and Seven Star LLC will prepare a quotation and confirm lead time. We are an independent supplier in Muscat and do not represent the manufacturer.

Other Models in the Eh Liquiline Range

Seven Star LLC supplies models from the Eh Liquiline range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser CM44P Liquiline Multichannel TransmitterLiquid Analytical SystemsView details
Endress+Hauser CM444R Liquiline DIN-Rail TransmitterLiquid Analytical SystemsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Endress+Hauser CM444R Technical Information Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser CM444R Liquiline DIN-Rail Transmitter

Answers from our engineering team on installation, compatibility and integration.

01What is the CM444R?
A DIN-rail Liquiline transmitter for up to four digital Memosens sensors with modular extension.
02Which parameters can it measure?
pH, ORP, ISFET, conductive and inductive conductivity, dissolved oxygen, nitrate and turbidity, in any combination.
03Which fieldbuses are offered?
PROFIBUS DP, Modbus RS485, Modbus TCP and Ethernet, among the platform options.
04Where must it be installed?
In a cabinet or protected room, as the transmitter itself is IP20.
05Can it control dosing?
Yes, the platform includes controller functions, and the document shows a chlorine dosing example with flow interlock.