Brand:

Danfoss 084H4501 AKS 4100 Liquid Level Sensor, 5 m Cable

Description

AKS 4100: a continuous liquid level sensor for refrigerant vessels

Danfoss 084H4501 is an AKS 4100 liquid level sensor in the cable version, with an insertion length of 5000 mm (197 in) and a G 1 process connection. The sensor measures the level of refrigerant in a vessel continuously and returns a 4 to 20 mA signal, so the plant controller can hold the level of a receiver, separator or flooded evaporator within a band.

The ratings are a maximum working pressure of 100 bar (1450 psig), a temperature range of -60 to 100 C, an ambient range of -40 to 80 C and enclosure IP67. The supply is 14 to 30 V DC, power consumption is 0.7 W, the maximum load resistance is 500 ohm and net weight is 2.3 kg. Approvals shown are CE, EAC and UA.

Technical specifications

Parameter Specification
Danfoss code number 084H4501
Type AKS 4100
Ambient temperature range -40 C to 80 C
Approvals as listed CE; EAC; UA
Connection size 1
Connection type G
Design Cable version
Enclosure rating IP IP67
Insertion length 197 in / 5000 mm
Load resistance max. 500 Ohm
Maximum working pressure 100 bar
Output signal 4 mA to 20 mA
Power consumption 0.7 W
Refrigerants R134a; R22; R401A; R402A; R404A; R407A; R407B; R407C; R407F; R409A; and others listed in the data sheet
Supply voltage DC 14 V to 30 V
Temperature range -60 C to 100 C
Net weight 2.3 kg
EAN 5702428414906

Continuous level measurement in refrigeration

Level sensors replace float switches where the controller needs a measured value rather than a high/low alarm: pump separators, liquid receivers, economisers and chiller evaporators. The 4 to 20 mA output is read by the controller, so the same sensor can drive an electronic expansion valve or a liquid feed valve in a level loop.

The package includes an HMI with menu languages English, German, French and Spanish, which is used to set the span and the output during commissioning. The 5 m cable version suits tall vessels; the AKS 4100U is a related variant with a different version of the output, listed under its own code.

Mounting and ordering notes

The sensor is lowered into a stilling pipe or standpipe in the vessel and sealed by the G 1 connection, so the nozzle size and the insertion length must match the vessel. Wire with screened cable and keep the signal line clear of power cables. Danfoss supplies the HMI and a brochure on flexibility and accuracy, and a separate catalogue for industrial refrigeration sensors.

Confirm vessel height, connection (G 1), refrigerant, signal and supply before ordering. Liquid level switch accessories and spare parts are listed on the product page.

Other types and sizes from the same Danfoss family that appear in the Danfoss store listing include AKS 32R (059G0047), AKS 2050 (059G0048), AKS 3000 (060G1007), AKS 3050 (060G1045), AKS 33 (060G1711), AKS 32 (060G1889), AKS 4100 U (084H4520), AKS 11 (084N0003). These are listed for orientation only; each has its own datasheet values, so check size, connection and version before ordering.

Related Danfoss products: Danfoss 032L1045 EVR 40 Solenoid Valve 2 1/8 in Solder NO, Danfoss 032L1188 EVR 10 Solenoid Valve 1/2 in Solder NC, Danfoss 032U7150 EV220B 50 Solenoid Valve G 2 NC 40 m3/h, Danfoss 027H2081 ICS3 25-10 Pilot-Operated Servo Valve, 25 mm, Danfoss 148B5441 SVA-L 25 Long-Neck Shut-off Valve, 25 mm and Danfoss 060G1712 AKS 33 Pressure Transmitter 0-34.5 bar.

Documents and quotation

Attached for download: Danfoss Liquid level sensor, type AKS 4100 and AKS 4100U AI243386442914en-001301 (manufacturer, unaltered), the manufacturer’s unaltered PDF. Browse comparable products in level instrumentation. To order, send us 084H4501 and the required quantity; Seven Star LLC is an independent supplier based in Muscat.

Datasheets & Documents
  • PDF Datasheet Danfoss Liquid level sensor, type AKS 4100 and AKS 4100U AI243386442914en-001301 (manufacturer, unaltered) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.

Danfoss company profile

Founded 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966)
First product Thermostatic expansion valve for refrigeration
Headquarters Nordborg, Denmark
Ownership Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family
Size About 42,000 employees (2023)
Business segments Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics)
Brands in the group VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls

Milestones

  • 1932–1933: First expansion valve; the company is founded in Nordborg.
  • 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
  • 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
  • 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
  • 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
  • 2021: Acquisition of Eaton's hydraulics business.

Choosing Danfoss products

For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.

Where Danfoss products are used

In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.

Danfoss products we list

Family Examples
Variable speed drives and soft starters VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter
Solenoid valves and coils EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil
Pressure switches and thermostats KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101
Pressure transmitters MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2
HVAC and refrigeration valves AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element

Ordering Danfoss products: what we need

Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.

Facts checked against Danfoss's company history pages and published company data, October 2026.

FAQ

Questions about the Danfoss 084H4501 AKS 4100 Liquid Level Sensor, 5 m

Answers from our engineering team on installation, compatibility and integration.

01What is Danfoss 084H4501?
An AKS 4100 continuous liquid level sensor, cable version, with 5 m insertion length and G 1 connection.
02What is the output signal?
4 to 20 mA, with a supply of 14 to 30 V DC.
03What is the pressure rating?
A maximum working pressure of 100 bar (1450 psig).
04What is the temperature range?
-60 to 100 C medium, -40 to 80 C ambient.
05Which document is attached?
The Danfoss liquid level sensor AKS 4100 and AKS 4100U data sheet AI243386442914en-001301.