Rosemount 2240S Multi-input Temperature Transmitter

Description

Overview

The Rosemount 2240S Multi-input Temperature Transmitter provides multiple spot temperature measurement in liquid storage tanks. Emerson uses it to calculate the average temperature of the liquid and to correct for stratification, which is essential when converting gauged level into net standard volume. The Rosemount 2240S connects up to sixteen 3- or 4-wire temperature elements and an integrated water level sensor, delivers a temperature conversion accuracy of 0.05 °C, and is approved for demanding custody transfer applications in line with API chapter 7.3.

Seven Star LLC supplies the Rosemount 2240S to crude and product terminals, refineries, LPG and LNG storage operators and EPC contractors in Oman and the GCC, from our office in Muscat. In large tanks a fraction of a degree of temperature error turns into a significant volume difference, so the transmitter is a key part of fiscal tank gauging alongside the radar level gauge.

Operating Principle

As the data sheet explains, the Rosemount 2240S reads each individual spot temperature element in a multiple spot temperature sensor installed in the tank. The value from each element is combined with the level value from the radar gauge, and the average liquid temperature is calculated from these values for net volume computation. Measured data, including temperature and free water level, is passed over the intrinsically safe two-wire Tankbus to a Rosemount 2410 Tank Hub, and can be viewed in Rosemount TankMaster software, on the tank hub display or on a Rosemount 2230 Graphical Field Display.

The water level sensor in the Rosemount 765 probe is factory calibrated, and any adjustment during installation can be made with the built-in on-line calibration feature of the transmitter. As general engineering background, measuring free water at the tank bottom matters because water must be subtracted from the gross volume, and a continuous electronic reading avoids manual dipping with water-finding paste on the tank roof.

Engineering Design of the Rosemount 2240S

The Rosemount 2240S is housed in a polyurethane-covered aluminium enclosure rated IP 66/67 and NEMA 4X, with ½-14 NPT or M20 x 1.5 cable connections, metal cable glands or Eurofast and Minifast connectors. It can be mounted directly on top of a Rosemount 565, 566 or 765 multiple spot sensor using an M33 x 1.5 connection, or separately on a wall or pipe with an installation kit. Supported sensors are the 565 multiple spot sensor, the 566 for cryogenic service such as LNG, the 765 with integrated water level sensor, and the 614 cryogenic spot sensor.

Inputs accept Pt-100 to IEC/EN 60751 and ASTM E1137, and Cu-90 elements, for use from -200 to 250 °C. Wiring can be 3-wire with common return, 3-wire individual or 4-wire individual, with up to 16 elements depending on the sensor model. The Tankbus is a FOUNDATION Fieldbus FISCO segment, with a quiescent current of 30 mA and a lift-off voltage of 9.0 VDC; the device is polarity insensitive and acts as a Link Master. TankMaster WinSetup is the recommended configuration tool, and the tank hub supports Tankbus auto-configuration. Metrology sealing and a write-protect switch are provided.

Key Features

The Rosemount 2240S data sheet lists the following capabilities.

  • Temperature conversion accuracy of 0.05 °C supports precise inventory calculations and custody transfer.
  • Up to sixteen 3- or 4-wire RTD spot elements can be connected to one transmitter.
  • An integrated water level sensor input reports free water level at the tank bottom.
  • Average liquid temperature is calculated from the individual spot values in combination with the radar level value.
  • Ambient temperature effect is limited to 0.05 °C over -40 to 70 °C.
  • Two-wire intrinsically safe Tankbus power and communication simplifies installation.
  • Cryogenic sensor options cover LNG and other liquefied gases in full containment tanks.
  • Metrology sealing and custody transfer type approvals are available for fiscal systems.

Industrial Applications

The Rosemount 2240S is used wherever bulk liquid inventories must be calculated accurately: crude oil export and storage tanks, refinery product tanks, aviation fuel farms, chemical and petrochemical storage, and refrigerated LPG and LNG tanks. Emerson also shows it in full containment LNG systems for average liquid temperature, redundant stratification monitoring, skin and cool-down temperature and leak detection. In Oman, these duties appear at coastal crude terminals, the refinery tank farms in Sohar and Duqm, and LNG and LPG facilities on the eastern coast. Operators upgrading older mechanical or manual systems can add the Rosemount 2240S tank by tank, because it shares the Tankbus with the radar gauge and needs no separate power cable, so the existing tank hub infrastructure is reused and the field wiring effort stays low.

Seven Star LLC supplies the Rosemount 2240S across the Sultanate of Oman and the GCC as part of complete tank gauging packages, together with instruments such as the Rosemount 3144P temperature transmitter and Rosemount 214C RTD temperature sensor for single point temperature, and the Rosemount 5408 non-contacting radar level transmitter for process vessels outside the fiscal tank farm.

Technical Specifications

The table below lists Rosemount 2240S data from Emerson product data sheet 00813-0100-2240.

Parameter Specification
Model Rosemount 2240S Multi-input Temperature Transmitter
Temperature conversion accuracy ± 0.05 °C over measuring range at ambient 20 °C
Ambient temperature effect ± 0.05 °C within -40 to 70 °C
Temperature measuring range -200 to 250 °C for Pt-100
Resolution 0.1 °C according to API chapter 7 and 12
Update time 4 seconds
Inputs Up to 16 RTD spot elements (3-wire or 4-wire) plus water level sensor
Sensor types Pt-100 (IEC/EN 60751, ASTM E1137) and Cu-90
Compatible sensors Rosemount 565, 566, 765 and 614
Communication FOUNDATION Fieldbus FISCO (Tankbus), Link Master
Quiescent current 30 mA; lift-off voltage 9.0 VDC
Housing Polyurethane-covered aluminium, IP 66/67, NEMA 4X
Configuration Rosemount TankMaster WinSetup; Tankbus auto-configuration

How to Order

To quote the Rosemount 2240S, Seven Star LLC needs the number of spot elements, sensor model and length, water level requirement, hazardous-area certification and any custody transfer approval. Download the Emerson product data sheet from this page for your design package. Seven Star LLC supplies Rosemount tank gauging equipment from Muscat to terminals and plants throughout Oman and the GCC, with sourcing and model selection support.

Datasheets & Documents
  • PDF Datasheet Emerson Rosemount 2240S Multi-input Temperature Transmitter Product Data Sheet (00813-0100-2240) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile

Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments

Milestones

1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.

Rosemount products we list

FamilyModelsTypical use

Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams

Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.

FAQ

Questions about the Rosemount 2240S Multi-input Temperature Transmitter

Answers from our engineering team on installation, compatibility and integration.

01What does the Rosemount 2240S measure?
The Rosemount 2240S reads up to sixteen spot temperature elements and an integrated water level sensor in a storage tank, and calculates the average liquid temperature used for net standard volume calculations.
02How accurate is the Rosemount 2240S?
Emerson specifies a temperature conversion accuracy of 0.05 degrees Celsius, with an ambient temperature effect of 0.05 degrees Celsius over -40 to 70 degrees Celsius and a resolution of 0.1 degrees Celsius according to API chapters 7 and 12.
03Which temperature sensors work with the Rosemount 2240S?
It is used with the Rosemount 565 multiple spot sensor, the cryogenic 566, the 765 with integrated water level sensor and the 614 cryogenic spot sensor, using Pt-100 or Cu-90 elements.
04How is the Rosemount 2240S connected?
It is powered and communicates over the intrinsically safe two-wire Tankbus, a FOUNDATION Fieldbus FISCO segment, to a Rosemount 2410 Tank Hub, and data can be viewed in Rosemount TankMaster.
05Does Seven Star LLC supply the Rosemount 2240S in Oman?
Yes. Seven Star LLC supplies the Rosemount 2240S from Muscat to terminals, refineries and gas facilities in Oman and the GCC, with sourcing and model selection support.