Brand:

AUMA FQM 12.1 Fail-Safe Unit for SQ 12.2 Actuators

Description

Overview

AUMA FQM 12.1 is the largest fail-safe unit in the FQM .1 range. It delivers a minimum torque of 1,200 Nm, is paired with the SQ 12.2 and gives a factory-set fail-safe time of 13 s to 39 s for a 90 degree stroke. At about 140 kg it is only slightly heavier than the FQM 10.1, but it carries the higher torque and a larger F14 flange.

Seven Star LLC, the official trusted supplier and regional supplier for AUMA, supplies the AUMA FQM 12.1 to power, desalination and oil and gas operators in Oman and the GCC. Safety valves of this size are important assets, so we review torque, flange, trigger logic and installation support with customers in Muscat, Sohar and Salalah.

Fail-Safe Action on Large Valves

The AUMA FQM 12.1 stores mechanical energy and releases it when an ESD signal at 24 V DC or a loss of mains supply triggers the function, driving the valve to its safe position with no electrical power needed. AUMA lists the fail-safe time as 13 s to 39 s for 90 degrees, set at the factory. The time grows with valve torque, and the minimum torque is 1,200 Nm, which makes this unit a match for the top of the SQ 12.2 tripping range.

In normal operation the SQ 12.2 moves the valve at operating times of 22 s to 63 s, so routine strokes are deliberately slow while the emergency stroke is defined separately. The ready contact and the isolated end position switches provide status feedback at 0.1 A and 30 V DC. As with the other sizes, the documented life is 500 fail-safe operations, which should be recorded in the proof-test log of the safety instrumented function.

Engineering Design of the AUMA FQM 12.1

The standard valve attachment of the AUMA FQM 12.1 is EN ISO 5211 F14, with F12 as the option, and the coupling accepts shafts up to 50 mm cylindrical, 36 mm square or 36 mm two-flat. The swing angle is adjustable between 80 and 96 degrees. AUMA’s data sheet gives a vibration resistance of 0.3 g with the F10 flange and 0.5 g with the F12 flange for the FQM 10.1 and 12.1 sizes at 10 to 200 Hz, so confirm the rating for the standard F14 flange with Seven Star LLC.

Plan for around 140 kg without actuator and controls, because the valve neck, bracket and pipe supports have to carry the combined mass. For the FQM 10.1 and 12.1 sizes, AUMA’s data sheet gives 0.3 g with the F10 flange and 0.5 g with F12 at 10 to 200 Hz, so confirm the rating for the standard F14 flange with Seven Star LLC. Mounting may be vertical or horizontal with a support, and never pointing downward. IP68 and KS apply, with a standard ambient range of -30 °C to +70 °C (option -40 °C to +60 °C) and -30 °C to +60 °C for the explosion-proof FQMEx 12.1.

Key Features

The AUMA FQM 12.1 provides a spring-powered safe state for large quarter-turn valves.

  • A 1,200 Nm minimum torque for large butterfly and ball valves.
  • The 13 s to 39 s fail-safe time balances speed against surge.
  • F14 standard flange, F12 option and shafts up to 50 mm.
  • Either an ESD signal or loss of mains, or both, releases the spring as ordered.
  • Status contacts for each end position and a ready output serve the safety system.
  • Rated for 500 fail-safe operations, which should be logged in the proof-test records.
  • Vibration resistance of up to 0.5 g with the F12 flange at 10 to 200 Hz.
  • Matched to the SQ 12.2; the explosion-proof FQMEx 12.1 uses the SQEx 12.2.

Selection Guidance for the AUMA FQM 12.1

Specifying the AUMA FQM 12.1 is a safety-function exercise. Define the safe position, the trigger, the required response time and the proof-test interval, and compare them with the 13 s to 39 s fail-safe time and the 500-operation lifetime. Confirm that the valve torque in the safe direction stays within the 1,200 Nm minimum capability.

Then review the mechanical stack: the SQ 12.2, the fail-safe unit and the valve together form a tall, heavy assembly. Ask the valve manufacturer to confirm the permissible mass and moment on the valve neck, and consider an additional support if the line vibrates.

Industrial Applications

The AUMA FQM 12.1 is used where a large valve must reach a safe position without electrical power: seawater intake isolation, large cooling water headers, gas feed shut-down and export line isolation. In power and desalination plants of the Gulf region, loss of the station supply is a credible event, and a spring-powered unit gives the plant a safe state that does not depend on batteries or generators.

In Oman and the GCC, Seven Star LLC supplies the FQM 12.1 on request with regional support.

Smaller units in the range: AUMA FQM 10.1, AUMA FQM 07.1 and AUMA FQM/FQMEx fail-safe unit family.

Engineers also review the AUMA SQ part-turn actuator range for the drive, the AUMA MATIC AM/AC integral actuator controls for control, and the AUMA SQEx explosion-proof part-turn actuator for explosion-proof assemblies.

Technical Specifications

The figures below describe the AUMA FQM 12.1, the largest unit of the range, as published by AUMA.

Parameter Specification
Model AUMA FQM 12.1 (for SQ 12.2)
Fail-safe operating time 13 – 39 s per 90° (factory setting, rises with torque)
Minimum torque 1,200 Nm
Suitable actuator SQ 12.2 (22 – 63 s)
Valve attachment (EN ISO 5211) F14 standard, F12 option
Valve shaft, max. 50 mm cylindrical, 36 mm square, 36 mm two-flat
Weight, approx. 140 kg plus actuator and controls
Vibration resistance, 10 – 200 Hz 0.3 g (F10) and 0.5 g (F12) in the FQM 10.1/12.1 entry; confirm for F14
Swing angle 80° to 96°
ESD input 24 V DC, approx. 1 A
Type of duty Open-close S2 – 15 min; modulating S4 – 25 % (not SIL)
Enclosure / corrosion protection IP68 / KS (KX option)
Ambient temperature -30 °C to +70 °C (option -40 °C to +60 °C)
Lifetime 500 fail-safe operations
Explosion-proof version FQMEx 12.1 with SQEx 12.2: -30 °C to +60 °C, ATEX and IECEx per its own sheet

Request a Quote for AUMA FQM 12.1

For the AUMA FQM 12.1, Seven Star LLC prepares a formal offer after receiving the valve datasheet, safe position, trigger signals and required closing time, and it names the SQ 12.2 and controls that complete the package. The AUMA data sheet is linked on this page. In Oman and the GCC, we supply the AUMA FQM 12.1 on request with technical support.

Datasheets & Documents
  • PDF Datasheet AUMA FQM 05.1 - FQM 12.1 Technical Data (Fail-Safe Unit) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.

Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.

AUMA company profile

Origin Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers.
Headquarters Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide.
Ownership Privately held, owner-managed company: AUMA Riester GmbH & Co. KG
Torque and thrust range Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA
Design principle Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty

Milestones

  • 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
  • Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
  • 1974: AUMA Benelux, the first foreign subsidiary, is founded.
  • Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.

AUMA actuator, controls and gearbox series

Series Type Typical use
SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 Multi-turn actuators, open-close duty Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher
SAR 07.2 to SAR 30.1 Multi-turn actuators, modulating duty Control valves that receive a continuous position setpoint and many starts per hour
SAV, SARV, SQV, SQRV Variable-speed actuators Slow approach to the seat to limit water hammer, fast travel elsewhere
SQ 05.2 to SQ 14.2, SQR Part-turn actuators Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action
SAEx, SAREx, SQEx, PROFOX-MX, TIGRON Explosion-proof actuators Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions
AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL Integral actuator controls AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions
GS, GHE, SA + GS combination Part-turn worm gearboxes Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm
GK, GST, GHT, GP Multi-turn gearboxes (bevel, spur, worm, planetary) Offset or right-angle drives and very high multi-turn torque
LE, SVC/SVCR, PROFOX-L Linear actuators and thrust units Globe and control valves with a rising stem, up to 217 kN
PROFOX-M, PROFOX-Q Compact smart actuators Small valves where a full SA or SQ is oversized
SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN Special versions Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service
SIMA2 Master station Fieldbus network management for many actuators on one plant

Where AUMA actuators are used

Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.

Ordering AUMA actuators and spare parts: what we need

For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.

Facts checked against AUMA product information and the company history published by AUMA, October 2026.

FAQ

Questions about the AUMA FQM 12.1 Fail-Safe Unit for SQ 12.2 Actuators

Answers from our engineering team on installation, compatibility and integration.

01What is the fail-safe time of the AUMA FQM 12.1?
AUMA lists 13 s to 39 s for a 90 degree stroke, set at the factory, and the time increases with the torque the valve requires.
02Which actuator is used with the AUMA FQM 12.1?
The SQ 12.2, with operating times of 22 s to 63 s in motor operation. The explosion-proof FQMEx 12.1 is paired with the SQEx 12.2.
03What is the weight of the AUMA FQM 12.1?
About 140 kg without the actuator and controls, so cranes and valve support checks are needed.
04What flange does the AUMA FQM 12.1 use?
EN ISO 5211 F14 is standard and F12 is an option, with shafts up to 50 mm cylindrical, 36 mm square or 36 mm two-flat.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC, so every unit is genuine AUMA product supplied with correct documentation and local technical support.