- Automation & ControlView all 3,086 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: AUMA
AUMA FQM 10.1 Fail-Safe Unit for SQ 10.2 Actuators
Description
Overview
AUMA FQM 10.1 is the first fail-safe unit of the family to step up to a larger housing, with a minimum torque of 600 Nm and a weight of about 137 kg. It is paired with the SQ 10.2 and provides a fail-safe time of 15 s to 54 s for 90 degrees, set at the factory. The jump in mass and valve interface from the 07.1 reflects the energy that must be stored to move a mid-size butterfly or ball valve.
Seven Star LLC supplies the AUMA FQM 10.1 to utilities, refineries and power plants throughout Oman and the GCC. For shut-down valves in Muscat, Sohar and Salalah we confirm the torque, the flange and the trigger logic with the project safety team.
Stored Energy for Mid-Size Valves
The AUMA FQM 10.1 moves the valve to a defined safe position using stored mechanical energy, so the movement continues even if the electrical supply has failed. The unit is released by an ESD signal at 24 V DC or by mains failure, and AUMA documents a fail-safe time of 15 s to 54 s for 90 degrees. The minimum torque of 600 Nm means the stored energy suffices for valves up to the top of the SQ 10.2 tripping range, and the time lengthens as torque demand grows.
In motor operation the unit works with the SQ 10.2 at operating times of 11 s to 63 s. The longer fail-safe times compared with the 07.1 are a design consequence of the higher torque class, and they suit pipelines where a rapid emergency closure could create a pressure surge. The ready contact and end position switches, rated 0.1 A at 30 V DC, report status, and the documented 500 fail-safe operations define the service life of the energy store.
Engineering Design of the AUMA FQM 10.1
The AUMA FQM 10.1 has an EN ISO 5211 F12 standard flange. F10 is available as an option, but only with a reduction flange, which AUMA notes explicitly. The coupling takes shafts up to 50 mm cylindrical, 36 mm square or 36 mm two-flat, and the swing angle is adjustable between 80 and 96 degrees.
Expect about 137 kg before the SQ 10.2 and controls, which means hoists on site and a check of the valve support. Vibration limits read 0.3 g for the F10 flange and 0.5 g for F12, tested between 10 and 200 Hz. Orientation may be vertical or horizontal with a support, but not downward. The enclosure is IP68 with KS protection, standard ambient is -30 °C to +70 °C (option -40 °C to +60 °C), and the explosion-proof FQMEx 10.1 is rated -30 °C to +60 °C.
Key Features
The AUMA FQM 10.1 gives mid-size shut-down valves a spring-powered safe state.
- A minimum torque of 600 Nm covers mid-size butterfly and ball valves.
- A fail-safe time of 15 s to 54 s limits surge on larger lines.
- F12 standard flange, with F10 only via a reduction flange.
- Shafts up to 50 mm cylindrical suit larger valve stems.
- Initiation by a 24 V DC ESD signal or by loss of mains supply, defined when the order is placed.
- A ready output and floating end position contacts report unit status to the safety logic.
- AUMA documents 500 fail-safe operations (ESD cycles) for the energy store.
- Paired with the SQ 10.2, with an explosion-proof FQMEx 10.1 for classified areas.
Selection Guidance for the AUMA FQM 10.1
For the AUMA FQM 10.1, the first decision is the mechanical interface. If the valve carries an F12 flange, the standard unit fits directly. If it carries F10, AUMA requires a reduction flange, which changes the stack height and must be reflected in the valve drawing. Next, compare the torque required in the safe direction with 600 Nm, and the allowed closing time with 15 s to 54 s.
Because the assembly is heavy, ask the valve supplier to confirm the permissible mass on the valve neck and the need for an additional support, particularly where vibration from pumps is present.
Industrial Applications
The AUMA FQM 10.1 is used on shut-down valves on pump discharge lines, cooling water headers, fuel and gas feeds and boiler inlet isolation, where the valve must reach a safe position even if power and control signals are lost. Power stations and desalination plants in the Sultanate use this class of valve for the emergency isolation of seawater circuits and auxiliary systems.
Adjacent units: AUMA FQM 07.1, AUMA FQM 12.1 and AUMA FQM/FQMEx fail-safe unit family.
The driving actuator is part of the AUMA SQ part-turn actuator range, the AUMA MATIC AM/AC integral actuator controls cover the controls, and the AUMA SQEx explosion-proof part-turn actuator is the hazardous-area counterpart.
Technical Specifications
AUMA’s FQM data sheet gives the following figures for the AUMA FQM 10.1, the first size built in the larger housing.
| Parameter | Specification |
|---|---|
| Model | AUMA FQM 10.1 (for SQ 10.2) |
| Fail-safe operating time | 15 – 54 s per 90° (factory setting, rises with torque) |
| Minimum torque | 600 Nm |
| Suitable actuator | SQ 10.2 (11 – 63 s) |
| Valve attachment (EN ISO 5211) | F12 standard, F10 option (only with reduction flange) |
| Valve shaft, max. | 50 mm cylindrical, 36 mm square, 36 mm two-flat |
| Weight, approx. | 137 kg plus actuator and controls |
| Vibration resistance, 10 – 200 Hz | 0.3 g with F10, 0.5 g with F12 |
| Swing angle | 80° to 96° |
| ESD input | 24 V DC, approx. 1 A |
| Type of duty | Open-close S2 – 15 min; modulating S4 – 25 % (not SIL) |
| Enclosure / corrosion protection | IP68 / KS (KX option) |
| Ambient temperature | -30 °C to +70 °C (option -40 °C to +60 °C) |
| Lifetime | 500 fail-safe operations |
| Explosion-proof version | FQMEx 10.1 with SQEx 10.2: -30 °C to +60 °C, ATEX and IECEx per its own sheet |
Request a Quote for AUMA FQM 10.1
Utilities and plant owners planning a shut-down valve package can ask Seven Star LLC for a quotation covering the AUMA FQM 10.1, the SQ 10.2 and the controls. Please state the flange, safe position, trigger and permitted closing time; the data sheet is linked on this page. In Oman and the GCC, we supply the AUMA FQM 10.1 on request, with lead time confirmed at quotation.
See also: AUMA AC 01.2-SIL Functional Safety Actuator Controls.
Datasheets & Documents
- Datasheet AUMA FQM 05.1 - FQM 12.1 Technical Data (Fail-Safe Unit) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.
Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.
AUMA company profile
| Origin | Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers. |
|---|---|
| Headquarters | Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide. |
| Ownership | Privately held, owner-managed company: AUMA Riester GmbH & Co. KG |
| Torque and thrust range | Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA |
| Design principle | Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty |
Milestones
- 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
- Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
- 1974: AUMA Benelux, the first foreign subsidiary, is founded.
- Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.
AUMA actuator, controls and gearbox series
| Series | Type | Typical use |
|---|---|---|
| SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 | Multi-turn actuators, open-close duty | Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher |
| SAR 07.2 to SAR 30.1 | Multi-turn actuators, modulating duty | Control valves that receive a continuous position setpoint and many starts per hour |
| SAV, SARV, SQV, SQRV | Variable-speed actuators | Slow approach to the seat to limit water hammer, fast travel elsewhere |
| SQ 05.2 to SQ 14.2, SQR | Part-turn actuators | Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action |
| SAEx, SAREx, SQEx, PROFOX-MX, TIGRON | Explosion-proof actuators | Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions |
| AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL | Integral actuator controls | AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions |
| GS, GHE, SA + GS combination | Part-turn worm gearboxes | Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm |
| GK, GST, GHT, GP | Multi-turn gearboxes (bevel, spur, worm, planetary) | Offset or right-angle drives and very high multi-turn torque |
| LE, SVC/SVCR, PROFOX-L | Linear actuators and thrust units | Globe and control valves with a rising stem, up to 217 kN |
| PROFOX-M, PROFOX-Q | Compact smart actuators | Small valves where a full SA or SQ is oversized |
| SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN | Special versions | Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service |
| SIMA2 | Master station | Fieldbus network management for many actuators on one plant |
Where AUMA actuators are used
Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.
Ordering AUMA actuators and spare parts: what we need
For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.
Facts checked against AUMA product information and the company history published by AUMA, October 2026.
Browse AUMA products by category: Valve Actuator, Industrial Communications.
FAQ
Questions about the AUMA FQM 10.1 Fail-Safe Unit for SQ 10.2 Actuators
Answers from our engineering team on installation, compatibility and integration.
01What is special about the flange of the AUMA FQM 10.1?
The standard attachment is EN ISO 5211 F12. F10 is possible only with a reduction flange, so state the valve flange clearly in the enquiry.
02What is the fail-safe time of the AUMA FQM 10.1?
AUMA lists 15 s to 54 s for a 90 degree stroke, set at the factory, increasing with the torque the valve requires.
03How heavy is the AUMA FQM 10.1?
About 137 kg, not including the SQ 10.2 actuator and the controls. Plan lifting equipment and valve support.
04What actuator drives the AUMA FQM 10.1 in normal operation?
The SQ 10.2, with operating times of 11 s to 63 s. The FQMEx 10.1 pairs with the SQEx 10.2.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC, so every unit is genuine AUMA product supplied with correct documentation and local technical support.


















Reviews
There are no reviews yet.