- Automation & ControlView all 3,062 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: AUMA
AUMA FQM 07.1 Fail-Safe Unit for SQ 07.2 Actuators
Description
Overview
AUMA FQM 07.1 is the second fail-safe unit in the range and doubles the minimum torque of the FQM 05.1 to 300 Nm. It is paired with the SQ 07.2 part-turn actuator, and it offers the shortest fail-safe time span of the family, 8 s to 26 s for a 90 degree stroke. For emergency shut-down valves where speed of closure matters, this is the fastest option AUMA documents.
Seven Star LLC, the official trusted supplier and regional supplier for AUMA, supplies the AUMA FQM 07.1 to oil, gas, power and water projects across Oman and the GCC. Our team works with safety engineers in Muscat, Sohar and Salalah to document the safe-state requirement, trigger logic and valve torque before an order is placed.
Faster Emergency Action at 300 Nm
The AUMA FQM 07.1 uses stored mechanical energy to move the valve when the ESD input or the mains supply triggers the function, so the emergency stroke does not depend on any electrical supply. The fail-safe time is set at the factory in the range of 8 s to 26 s, and it lengthens as the valve torque demand rises. The minimum torque is 300 Nm, so a valve whose torque in the safe direction is lower than that will move as designed, while one that needs more cannot be served by this size.
In normal operation the SQ 07.2 provides the motor stroke at operating times of 5.6 s to 32 s, which gives the process a fast routine movement and the safety function a separately defined emergency time. A ready signal contact and two galvanically isolated end position switches report the unit state, each rated for 0.1 A at 30 V DC. Documented lifetime is 500 fail-safe operations, which should be counted against any proof-test plan that includes full-stroke tests.
Engineering Design of the AUMA FQM 07.1
The standard valve attachment of the AUMA FQM 07.1 is EN ISO 5211 F10, with F07 as the option, which is the reverse of the FQM 05.1. The coupling accepts shafts up to 25.4 mm cylindrical, 22 mm square or 22 mm two-flat. The swing angle can be adjusted between 80 and 96 degrees, and the unit weighs about 66 kg without actuator and controls.
At roughly 66 kg without actuator and controls, the FQM 07.1 is only slightly heavier than the 05.1. Because F10 is the standard flange, the higher 0.5 g vibration rating at 10 to 200 Hz applies by default, and choosing F07 drops it to 0.3 g. The unit installs vertically or horizontally with a support, never pointing downward. AUMA specifies IP68, KS corrosion protection with a KX option, and -30 °C to +70 °C for the standard unit (option -40 °C to +60 °C), while the explosion-proof FQMEx 07.1 is rated -30 °C to +60 °C.
Key Features
The AUMA FQM 07.1 offers the quickest fail-safe action in the FQM family together with a 300 Nm torque reserve.
- A 300 Nm minimum torque doubles the reserve of the smallest unit for moderate-torque valves.
- The 8 s to 26 s fail-safe time is the fastest range of the family.
- F10 is the standard flange, which gives the higher 0.5 g vibration rating.
- The initiation criterion, ESD signal, mains failure or both, is chosen when the order is placed.
- A ready signal and isolated end position switches report unit state at 0.1 A and 30 V DC.
- The energy store is rated for 500 fail-safe operations.
- Pairs with the SQ 07.2 and AC controls as a modular package.
- FQMEx 07.1 is the Zone 1 version, documented in its own data sheet.
Selection Guidance for the AUMA FQM 07.1
With the AUMA FQM 07.1, begin from the safety requirement specification: required safe position, response time, and proof-test interval. Compare the 8 s to 26 s fail-safe time with the closing time allowed by the process hazard analysis, and remember that heavier valves take longer. Then confirm the valve torque against the 300 Nm minimum, and the flange against F10 or F07.
As the unit adds about 66 kg above the valve, the valve and pipe supports should be reviewed by the piping designer before installation.
Industrial Applications
The AUMA FQM 07.1 suits emergency isolation of mid-small valves on fuel gas feeds, flare knock-out drain lines, boiler feedwater and cooling water headers, where a power failure must close or open the valve without delay. Because its fail-safe time begins at 8 s, it is also used where a trip must be completed quickly to prevent a hazardous situation from developing.
In Oman and the GCC, Seven Star LLC supplies the FQM 07.1 on request with local support.
Neighbouring sizes: AUMA FQM 05.1, AUMA FQM 10.1 and AUMA FQM/FQMEx fail-safe unit family.
For the drive side see the AUMA SQ part-turn actuator range, for controls the AUMA MATIC AM/AC integral actuator controls, and for Zone 1 duty the AUMA SQEx explosion-proof part-turn actuator.
Technical Specifications
Key figures for the AUMA FQM 07.1 as listed by AUMA; the explosion-proof FQMEx 07.1 is documented in its own sheet with a lower upper ambient limit.
| Parameter | Specification |
|---|---|
| Model | AUMA FQM 07.1 (for SQ 07.2) |
| Fail-safe operating time | 8 – 26 s per 90° (factory setting, rises with torque) |
| Minimum torque | 300 Nm |
| Suitable actuator | SQ 07.2 (5.6 – 32 s) |
| Valve attachment (EN ISO 5211) | F10 standard, F07 option |
| Valve shaft, max. | 25.4 mm cylindrical, 22 mm square, 22 mm two-flat |
| Weight, approx. | 66 kg plus actuator and controls |
| Vibration resistance, 10 – 200 Hz | 0.3 g with F07, 0.5 g with F10 |
| Swing angle | 80° to 96° |
| ESD input | 24 V DC, approx. 1 A |
| Type of duty | Open-close S2 – 15 min; modulating S4 – 25 % (not SIL) |
| Enclosure / corrosion protection | IP68 / KS (KX option) |
| Ambient temperature | -30 °C to +70 °C (option -40 °C to +60 °C) |
| Lifetime | 500 fail-safe operations |
| Explosion-proof version | FQMEx 07.1 with SQEx 07.2: -30 °C to +60 °C, ATEX and IECEx per its own sheet |
Request a Quote for AUMA FQM 07.1
Procurement and safety teams in Oman and the GCC can request a priced offer for the AUMA FQM 07.1 by sending the valve datasheet, the safe-state requirement and the trip signals. The offer will include the matching SQ 07.2 and controls, and the data sheet is available for download here. Seven Star LLC supplies AUMA products in Oman and the GCC and quotes the AUMA FQM 07.1 on request.
See also: AUMA AMExC 01.1 Explosion-Proof Actuator Controls.
Datasheets & Documents
- Datasheet AUMA FQM 05.1 - FQM 12.1 Technical Data (Fail-Safe Unit) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.
Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.
AUMA company profile
| Origin | Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers. |
|---|---|
| Headquarters | Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide. |
| Ownership | Privately held, owner-managed company: AUMA Riester GmbH & Co. KG |
| Torque and thrust range | Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA |
| Design principle | Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty |
Milestones
- 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
- Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
- 1974: AUMA Benelux, the first foreign subsidiary, is founded.
- Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.
AUMA actuator, controls and gearbox series
| Series | Type | Typical use |
|---|---|---|
| SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 | Multi-turn actuators, open-close duty | Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher |
| SAR 07.2 to SAR 30.1 | Multi-turn actuators, modulating duty | Control valves that receive a continuous position setpoint and many starts per hour |
| SAV, SARV, SQV, SQRV | Variable-speed actuators | Slow approach to the seat to limit water hammer, fast travel elsewhere |
| SQ 05.2 to SQ 14.2, SQR | Part-turn actuators | Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action |
| SAEx, SAREx, SQEx, PROFOX-MX, TIGRON | Explosion-proof actuators | Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions |
| AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL | Integral actuator controls | AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions |
| GS, GHE, SA + GS combination | Part-turn worm gearboxes | Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm |
| GK, GST, GHT, GP | Multi-turn gearboxes (bevel, spur, worm, planetary) | Offset or right-angle drives and very high multi-turn torque |
| LE, SVC/SVCR, PROFOX-L | Linear actuators and thrust units | Globe and control valves with a rising stem, up to 217 kN |
| PROFOX-M, PROFOX-Q | Compact smart actuators | Small valves where a full SA or SQ is oversized |
| SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN | Special versions | Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service |
| SIMA2 | Master station | Fieldbus network management for many actuators on one plant |
Where AUMA actuators are used
Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.
Ordering AUMA actuators and spare parts: what we need
For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.
Facts checked against AUMA product information and the company history published by AUMA, October 2026.
Browse AUMA products by category: Valve Actuator, Industrial Communications.
FAQ
Questions about the AUMA FQM 07.1 Fail-Safe Unit for SQ 07.2 Actuators
Answers from our engineering team on installation, compatibility and integration.
01What is the fail-safe time range of the AUMA FQM 07.1?
8 s to 26 s for a 90 degree stroke, set at the factory, and it increases with the torque the valve requires.
02What is the minimum torque of the AUMA FQM 07.1?
AUMA lists 300 Nm as the minimum torque for the fail-safe movement. The matching actuator is the SQ 07.2.
03Which flange is standard on the AUMA FQM 07.1?
EN ISO 5211 F10 is standard and F07 is an option. Vibration resistance is 0.5 g with F10 and 0.3 g with F07.
04Can the AUMA FQM 07.1 be mounted in any position?
It can be mounted vertically or horizontally with a support. A downward-pointing mounting position is not permitted.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC, so every unit is genuine AUMA product supplied with correct documentation and local technical support.


















Reviews
There are no reviews yet.